|
Anleitung Zusammenfassung
NOTE: If it is intended to fit the stove into an existing brickbuilt chimney without a closure plate*, a 5" (127mm) liner must be used. Larger lined flues may work, but in some instances could cause cold start flue problems resulting in nuisance shutdown. Lined flues above 7" (175mm) are not recommended. 2.1 The large stove has a rated output in excess of 7Kw and requires a minimum of 11cm2 permanent effective free air. This is in addition to any window that opens, and although it must communicate with the outside air whenver possible, it can communicate with an adjacent room providing such space has a similar opening to the outside. The small and medium stoves have a rated output below 7Kw and do not normally require any additional ventilation. 3.1 Before installation, ensure the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. 3.2 Ensure that the gas supply is capable of delivering the required amount of gas, and is in accordance with the rules in force. 3.3 Soft copper tubing and soft soldered joints can be used but must not be closer than 50mm to the base of the tray. 3.4 A means of isolating the gas supply to the appliance must be provided, independent of any appliance control. 3.5 All supply gas pipes must be purged of any debris that may have entered, prior to connection to the appliance. 4.1 This stove must stand on a non-combustible hearth that is at least 12mm thick and projects 50mm minimum from the base of the stove in all directions. 4.2 Do not install in a room that contains a bath or shower. MINIMUM CLEARANCE 4.3 The stove is not suitable for installation against a combustible wall. All combustible materials must be removed from behind the stove. 4.4 Ensure you comply with all minimum clearance measurements, whether or not to combustible materials. The above dimensions povide adequate clearance at the side and rear of the fire so that the controls can be reached. 2A * * Air-space to non-combustible 3. INSTALLATION OF THE GAS SUPPLY 2. VENTILATION 4. APPLIANCE LOCATION 2 1. FLUE AND CHIMNEY REQUIREMENTS 1 AR0604 A = 811mm B = 527 mm C = 12 mm 2.7 The stove is fitted with the Gazco Flue Sure System, which acts to cut off the gas supply to the appliance in the event of incorrect operation of the flue. If the system acts to shut off the gas supply, this indicates there is insufficient flue pull. If this occurs a minimum of 10 minutes should be allowed before trying to relight. Continued operation of this safety device means there may be a serious problem with the flue system and a qualified gas engineer must inspect. DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT IS SAFE TO DO SO. 2.8 Do not tamper with the Flue Sure System Use only genuine Gazco replacement parts when servicing the system - refer to Servicing Instructions, Replacing Parts. THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES. 3.1 Open the carton containing the engine assembly, and carefully remove the engine. It will now be necessary to decide upon top or rear flue exit, the stove is factory built for rear flue exit, but it may be changed to top exit by simply using the following method. 3.2 Remove the flue spigot from the rear of the stove and replace with the blanking plate from the top of the stove. Refit flue spigot to top of stove. 3.3 When installing with a top flue please note the flue pipe fits through a hole in the top grill, the dimensions are for floor fixing a top flue installation with clearance for side panels. 3.4 Position the engine assembly in its intended location and mark the position of the two floor fixing holes at the base of each side of the subframe, minimum fixing dimensions to a rear wall are shown in diagram 2. 10 IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS OF THIS BOOKLET. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SERVICING INSTRUCTIONS, REPLACING PARTS. 1.1 This stove is fitted with a control valve that can be easily upgraded to battery powered remote control. There are two versions of this control which can be obtained through your local Gazco stockist. 1.2 This upgrade can be fitted before or after installation but if side clearances are limited then it will be easier to upgrade the stove before installation. Full instructions are included with the kit. 1.3 STANDARD REMOTE CONTROL. This remote controls the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning GAZCO PART NUMBER 8455. 1.4 THERMOSTATIC AND TIMER REMOTE CONTROL. This remote controls the gas appliance after the pilot has been lit. In ‘MANUAL MODE’ it can be used to turn the main burner on and manually regulate it from low through to high and b...
Dieses Handbuch ist für folgende Modelle:Kamine - AR0367 (383.21 kb)
Kamine - AR0366 (383.21 kb)
Kamine - AR0369 (383.21 kb)
Kamine - AR0887 (383.21 kb)