If the voltage is lower than full current, check the wiring. If the wiring checks out good, the board is bad. SMOKE SMELL COMING BACK INTO THE HOME Possible Causes: Possible Remedies: 1. There is a leak in the vent pipe system. Inspect all vent pipe connections. Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher. Also, seal joints with UL-181-AP foil tape. Also, make sure the square to round adapter piece on the combustion blower has been properly sealed with the same RTV. 2. The gasket on the combustion blower has gone bad. Inspect both gaskets on the combustion blower to make sure they are in good shape. CONVECTION BLOWER SHUTS OFF AND COMES BACK ON Possible Causes: Possible Remedies: 1. The convection blower is overheating and tripping the internal temperature shutoff. Clean any dust off of the windings and fan blades. If cleaning the blower does not help, it may be bad. 2. Circuit board malfunction. Test the current going to the convection blower. If there is power being sent to the blower when it is shut off, then the control board is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. TROUBLESHOOTING GUIDE 25 TROUBLESHOOTING GUIDE26 TROUBLESHOOTING GUIDE26 STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes: Possible Remedies: 1. Fuse on control board blew Remove the control board. On the back there is one fuse. If it appears to be bad, replace it with a 5 Amp 250 Volt fuse. Plug the stove back in and try to run the unit. 2. High limit switch has tripped or is defective Wait for the stove to cool for about 30 - 45 minutes. It should now function normally. If not use the owner’s manual to locate the high limit thermodisk. To test if the thermodisk is bad, you can bypass it as described previously for the POF thermodisk. 3. Bad auger motor Remove the auger motor from the auger shaft and try to run the unit. If the motor will turn, the shaft is jammed on something. If the motor will not turn, the motor is bad. 4. Auger jam Start by emptying the hopper. Then remove the auger motor by removing the auger pin. Remove the auger shaft inspection plate in the hopper so that you can see the auger shaft. Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing. Next, remove the two nuts that hold the top auger biscuit in. Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove. After you have removed the shaft, inspect it for bent flights, burrs, or broken welds. Remove any foreign material that might have caused the jam. Also, check the auger tube for signs of damage such as burrs, rough spots, or grooves cut into the metal that could have caused a jam. 5. Loose wire or connector Check all wires and connectors that connector to the auger motor, high limit switch, and the Molex connector. 6. Bad control board If the fuse is good, the wires and connectors check out good, and the high limit switch did not trip, test for power going to the auger motor. If there is not a full current going to the auger motor when the fuel feed light is on, you have a bad control board. TROUBLESHOOTING GUIDE 27 TROUBLESHOOTING GUIDE 27 • GLASS “SOOT’S” UP AT A VERY FAST RATE • FLAME IS LAZY, DARK, AND HAS BLACK TIPS • AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Possible Remedies: 1. Stove or vent pipe is dirty, which restricts airflow through the burnpot. Follow all cleaning procedure in the maintenance section of the owner’s manual. 2. Vent pipe installed improperly. Check to make sure the vent pipe has been installed according to the criteria in the owner’s manual. 3. Air damper is set too far in (closed) for a higher setting. Pull the damper knob farther out away from the side of the stove and try to burn the unit again. 4. Burnpot holes are blocked. Remove the burnpot and thoroughly clean it. 5. Air damper is broken. Visually inspect the damper assembly. Make sure the damper plate is attached to the damper rod. When the damper rod is moved the plate should move with it. 6. Blockage in air intake pipe. Visually inspect the air intake pipe that leads into the burnpot for foreign material. 7. Circuit board malfunction. Time the fuel feed light at each setting (after the stove has completed the startup cycle). Make sure the times match the auger timing chart. If the auger motor runs constantly, the board is bad. 8. Combustion blower is not spinning fast enough. Test the RPM on the blower after the blades have been cleaned. The RPM should be approximately 3000 RPM. 9. Bad Pellets (Applies to GLASS “SOOT’S” UP AT A VERY FAST RATE Only) The brand of pellets or the batch of pellets that are being used may be of poor quality. If possible, try a different brand of pellets. You might also want to try a brand that is made from a different type of wood...

Dieses Handbuch ist für folgende Modelle:
Kamine - LUXURY SERIES P2000FS (567.94 kb)
Kamine - LUXURY SERIES P2000I (567.94 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien