Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Hearth and Home Technologies, modell 6000GLX-IPILP-R

Hersteller: Hearth and Home Technologies
Dateigröße: 3.67 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


4-4 3-4 3-4 3-3 35 ft. 4-4 3-4 3-4 3-3 40 ft. 5-4 4-4 4-4 3-4 V1 H1 Maximum V2 V1 + V2 Min. Elbow only 2 ft. 610 mm * * * 6 in. 152 mm 6 ft. 1.8 m * * * 2 ft. 610 mm 11 ft. 3.4 m * * * 3 ft. 914 mm 16 ft. 4.9 m * * * 4 ft. 1.2 m 20 ft 6.1 m * * * V1 + V2 + H1 = 50 ft (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT V1 + V2 + H1 cannot exceed 50 ft (15.2 m) Note: If the DVP-2SL or DVP-SLP24 adapter is used with SLP pipe, you MUST subtract one number from the table above. Example: Top vent 40 ft vertical with DVP pipe = 5-4 Top vent 40 ft vertical with SLP pipe = 4-3 .. 28 Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. S • 12/08 Figure 7.12 Top Vent - Vertical Termination - (continued) Three Elbows INSTALLED HORIZONTALLY H1 H2 V1 V2 V1 H1 + H2 V2 V1 + V2 Minimum H1 + H2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm 2 ft. 610 mm * * * 2 ft. 610 mm 2 ft. 610 mm 4 ft. 1.2 m * * * 4 ft. 1.2 m 3 ft. 914 mm 9 ft. 2.7 m * * * 9 ft. 2.7 m 4 ft. 1.2 m 18 ft. 5.5 m * * * 18 ft. 5.5 m H1 + H2 = 20 ft (6.1 m) Maximum V1 + V2 + H1 + H2 = 40 ft (12.2 m) Maximum Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. S • 12/08 29 Rear Vent - Horizontal Termination Figure 7.13 Figure 7.14 No Elbow One 45. Elbow H1 H1 H1 = 16 in. (406 mm) Maximum Do not use a 45. elbow in corner installations. Use two 90. elbows instead. 30 Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. S • 12/08 INSTALLED HORIZONTALLY H3 H1 H2 V1 Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 Figure 7.16 Three Elbows H1 H2 V1 H1 Maximum V1 Minimum H2 H1 + H2 Maximum 1 ft. 305 mm Back to Back 90. Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. 152 mm 2 ft. 610 mm 4 ft. 1.2 m 3 ft. 914 mm 1 ft. 305 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 2 ft. 610 mm 4 ft. 1.2 m 7 ft. 2.1 m 3 ft. 914 mm 3 ft. 914 mm 9 ft. 2.7 m 12 ft. 3.7 m 3 ft. 914 mm 4 ft 1.2 m 18 ft. 5.5 m 20 ft.* 6.1 m* V1 + H1 + H2 = 40 ft (12.2 m) Maximum H1 = 3 ft (914 mm) Maximum *H1 + H2 = 20 ft (6.1 m) Maximum H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max. 1 ft. 305 mm Back to Back 90. Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. 152 mm 1.5 ft. 457 mm 3.5 ft. 1.1 m 3 ft. 914 mm 1 ft. 305 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 2 ft. 610 mm 4 ft. 1.2 m 7 ft. 2.1 m 3 ft. 914 mm 3 ft. 914 mm 9 ft. 2.7 m 12 ft. 3.7 m 3 ft. 914 mm 4 ft. 1.2 m 12 ft. 3.7 m 15 ft. 4.6 m V1+ H1+ H2+ H3= 40 ft (12.2 m) Maximum H1= 3 ft (914 mm) Maximum H1+ H2+ H3= 20 ft (6.1 m) Maximum Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. S • 12/08 31 Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 H1 V1 INSTALLED HORIZONTALLY H1 H2 V2 V1 Minimum H1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft. 1.2 m 8 ft 2.4 m 5 ft. 1.5 m 8 ft 2.4 m V1 + H1 = 40 ft (12.2 m) Maximum H1 = 8 ft (2.4 m) Maximum H1 + H2 Maximum V1 Minimum Back to Back 90. Elbows 3 ft. 914 mm 2 ft 610 mm 6 ft. 1.8 m 4 ft 1.2 m 9 ft. 2.7 m 6 ft. 1.8 m 12 ft. 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m V1 + H1 = 40 ft (12.2 m) Maximum H1 + H2 = 8 ft (2.4 m) Maximum 32 Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. S • 12/08 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INSTALLED HORIZONTALLY H3 H1 H2 V1 V2 V1 H2 H1 H1 H2 H3 V1 Minimum H1 + H2 + H3 Maximum * * * 8 ft. 2.4 m 6 ft. 1.8 m * * * 9 ft. 2.7 m 7 ft. 2.1 m * * * 10 ft. 3.1 m 8 ft. 2.4 m * * * 10 ft. 3.1 m 8 ft. 2.4 m V1 + H1 + H2 + H3 = 40 ft. (12.2 m) Maximum *No specifi c restrictions on this value EXCEPT V1 + H1 + H2 + H3 cannot exceed 40 ft. (12.2 m) Maximum H1 + H2 + H3 = 8 ft. (2.4 m) Maximum H1 Maximum V1 Minimum H2 H1 + H2 Maximum 2 ft. 610 mm 6 in. 152 mm 2 ft. 610 mm 4 ft. 1.2 m 3 ft. 914 mm 1 ft. 305 mm 4 ft. 1.2 m 7 ft. 2.1 m 5 ft. 1.5 m 2 ft. 610 mm 6 ft. 1.8 m 11 ft. 3.4 m 7 ft. 2.1 m 3 ft. 914 mm 8 ft. 2.4 m 15 ft. 4.6 m 8 ft 2.4 m 4 ft. 1.2 m 10 ft. 3.1 m 18 ft. 5.5 m H1= 8 ft (2.4 m) Max. V1 + V2 + H1 + H2= 40 ft (12.2 m) Max. H1 + H2 = 20 ft (6.1 m) Max. Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. S • 12/08 33 A* B* 10 in. 12 in. C D 10 in. 10 in. A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep insulation or other material away from vent pipe may cause over heating and fi re. 8 Vent Clearances and Framing Figure 8.2 Wall Penetration * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.1 Horizontal Venting Clearances To Combustible Materials *When using SLP or SL-D pipe, minimum clearances from the vent pipe to combustible materials at inside wa...

Dieses Handbuch ist für folgende Modelle:
Kamine - 6000GLX-IPI-R (3.67 mb)
Kamine - 6000GLX-IPI-S (3.67 mb)
Kamine - 6000GLX-IPILP-S (3.67 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien