Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Hearth and Home Technologies, modell 6000GLX-IPI-S

Hersteller: Hearth and Home Technologies
Dateigröße: 3.67 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• 1-1/2 (38 mm) minimum overlap of fl ue telescoping section is required. Failure to maintain overlap may cause overheating and fi re. • Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base. • Flash and seal as appropriate for siding material at outside edges of cap. • When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149 installation codes and refer to Section 6 of this manual. CAUTION! Risk of Burns! Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap. NOTICE: For certain exposures which require superior resistance to wind-driven rain penetration, a fl ashing kit and HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Cap Specifi cation Chart (depth without using additional pipe sections) 6000 Series DVP-TRAPK1 Top Vent Depth DVP-TRAP1 Rear Vent Depth DVP-TRAPK2 Top Vent Depth DVP-TRAP2 Rear Vent Depth 2-3/4 in. to 4-5/8 in. 3-1/8 in. to 5 in. 5-1/8 in. to 9-1/8 in. 5-1/2 in. to 9-1/2 in. DVP-HPC1 Top Vent Depth DVP-HPC1 Rear Vent Depth DVP-HPC2 Top Vent Depth DVP-HPC2 Rear Vent Depth 2-3/4 in. to 4-7/8 in. 3-1/8 in. to 5-1/4 in. 4-7/8 in. to 9 in. 5-1/4 in. to 9-3/8 in. DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) 1 1111 Gas Information A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and approved parts. B. Gas Pressure • Optimum appliance performance requires proper input pressures. • Gas line sizing requirements will be determined in ANSI Z223.1 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada. • Pressure requirements are: Gas Pressure Natural Gas Propane Minimum inlet pressure 5.0 in. w.c. 11.0 in. w.c. Maximum inlet pressure 14.0 in. w.c. 14.0 in. w.c. Manifold pressure 3.5 in. w.c. 10.0 in. w.c. WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure may cause explosion. • Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating. • Install regulator upstream of valve if line pressure is greater than 1/2 psig. WARNING Fire Risk. Explosion Hazard. High pressure will damage valve. • Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig. • Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig. Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter). Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance. • Gas line may be run through knockout(s) provided. • The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration. • Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes. • Pipe incoming gas line into valve compartment. • Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve. WARNING! Risk of Fire or Explosion! Support control when attaching pipe to prevent bending gas line. • A small amount of air will be in the gas supply lines. WARNING! Risk of Fire or Explosion! Gas build-up during line purge could ignite. • Purge should be performed by qualified service technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open flames. Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally. WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loosened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. D. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When instal...

Dieses Handbuch ist für folgende Modelle:
Kamine - 6000GLX-IPI-R (3.67 mb)
Kamine - 6000GLX-IPILP-R (3.67 mb)
Kamine - 6000GLX-IPILP-S (3.67 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien