Anleitung Zusammenfassung
Theflamemaynotappearyellowimmediately;allow15to30 minutes for the final flame colour to be established. figure 69 figure 68 AIR SHUTTER OPENING W4 5-0536 / C / 09.06.06 8 REPLACEMENTS Contact your dealer for questions concerning prices and avail-1. MoDel & SeRIal nuMBeR oF FIReplace ability of replacement parts. Normally all parts can be ordered 2. InStallatIon Date oF FIReplace through your Napoleon dealer or distributor. 3. paRt nuMBeR When ordering replacement parts always give the following 4. DeScRIptIon oF paRt information: 5. FInISH for warranty replacement parts, a photocopy of * identifies items which are not illustrated. for the original invoice will be required to honour further information, contact your napoleon the claim. dealer. # REPLACEMENT PARTS PART NO. DESCRIPTION GD220 (5 FT) FLEXIBLE vENT KITS 40* W0 0-0397 4” FLEXIBLE ALUMINIUM LINER W 35-0 67 # - REAR LOG -(5 Ft) c/w SpaceRS W 35-0 68 # - MIDDLE LOG 40* W4 0-00 7 7” FLEXIBLE ALUMINIUM LINER - (5 Ft) 3 W 35-0 69 #3 - RIGHT LOG 4 W 35-0 70 #4 - LEFT LOG GD330 (10 FT) 5 W 35-0 73 #5 - LEFT STICK 4 * W0 0-0300 4” FLEXIBLE ALUMINIUM LINER 6 W 35-0 74 #6 - RIGHT STICK -(10 Ft) c/w SpaceRS 7 GL-654 LOG SET ASSEMBLy 4 * W4 0-00 8 7” FLEXIBLE ALUMINIUM LINER - (10 Ft) 8* W390-000 DOOR LATCH (ea) 4 * W0 0-0370 WALL SUPPORT ASSEMBLy 9 W7 5-0044 NATURAL GAS VALVE - MODULATING 9 W7 5-0045 PROPANE GAS VALVE - MODULATING 0 W455-00 7 NATURAL GAS ORIFICE #4 0 W455-0003 PROPANE GAS ORIFICE #54 TERMINAL KITS 43 PERISCOPE - GD 0 W680-0005 THERMOCOUPLE ** 44 WALL TERMINAL KIT - GD R W 40-0005 ELECTRODE c/w LEAD 3 W680-0004 THERMOPILE 4 W0 0- 94 NATURAL GAS PILOT ASSEMBLy 4 W0 0- 0 PROPANE GAS PILOT ASSEMBLy ROOF TERMINAL KITS 45* / TO 7/ PITCH - GD 0 5 W455-0070 NG PILOT INjECTOR 46* 8/ TO / PITCH - GD 5 W455-0068 LP PILOT INjECTOR 47* FLAT ROOF - GD 6* W385-0 45 NAPOLEON LOGO 48* W490-0073 4/7 INNER/OUTER SLEEVE 7* W56 -0008 DOOR GASKET ( 00 INCHES) 49 W670-0006 4/7 TERMINAL 8 W 00-0087 BURNER 50 W 70-0086 STORM COLLAR 9 GD 55 BLOWER 5 W0 0-0453 ROOF SUPPORT 0 W660-004 SPARK SWITCH 5 W 63-0065 / ROOF FLASHING W660-0046 REMOTE TRANSMITTER W 63-0066 / W660-0045 REMOTE RECEIVER W 63-0067 3 W 90-00 7 DC SPARK UNIT CONTROL 4 W300-0067 ACCENT LIGHT GLASS 5 W387-0006 ACCENT LAMP 6 W750-0 07 ACCENT LIGHT WIRE 53* W573-0007 HI-TEMP SEALANT ACCESSORIES 7 W 90-0080 ACCENT LENSE GASKET 54* GD50 HEAT GUARD 8* W36 -00 7 INSULATION SLEEVE 55 GA-566 HOT AIR DISTRIBUTION KIT 9* W475-040 PANEL, REAR FIBRE 56 GA-7 HOT AIR EXHAUST KIT 30* W475-040 PANEL, RIGHT FIBRE 57 GA-70 EXTENSION KIT, 5FT FLEX VENT 3 * W475-0403 PANEL, LEFT FIBRE 58* W0 0-0370 WALL SUPPORT ASSEMBLy 3 W 5-0 7 DOOR 59* W 75-000 4” COUPLER 33* W300-008 GLASS 60* W 75-00 3 7” COUPLER 34 W500-0 05 RESTRICTOR 6 * W 75-0 39 CONVERSION KIT - ng to lp 35 W585-0 98 FIRESTOP SPACER SHIELD 6 * W 75-0 40 CONVERSION KIT - lp to ng 36 W500-0 9 FIRESTOP SPACER 63 gD811-Kt HeRRIngBone/SanDStone BRIcK KIt 64 w135-0148 anDIRon 65* gD812-Kt ReFRactoRY panel KIt 66 RFK82 RecTANGLE FACING KIT 67 AFK8 ARCHED FACING KIT 68* RFK8 WI WROUGHT IRON FACING KIT 69 W 35-0 7 ANDRION (OBELISK) ** WArNiNg: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. W4 5-0536 / C / 09.06.06 29 W415-0536 / C / 09.06.06 44 43 56 55 53 19 9 22 21 20 18 23 32 62 68 AUX ON 0:00 00 ON/OFF FEATURE SELECT 63 26 24 27 25 36 35 2 13 11 15 14 12 66 49 50 7 51 1 4 3 52 67 5 6 TROUBLE SHOOTING GUIDE BeFoRe atteMptIng to tRouBleSHoot, puRge YouR unIt anD InItIallY lIgHt tHe pIlot anD tHe MaIn BuRneR wItH tHe glaSS DooR open. SYMPTOM PROBLEM TEST SOLUTION Main burner flame Blockage in vent. -remove blockage. In really cold conditions, ice buildup may occur on is a blue, lazy, the terminal and should be removed as required. transparent flame. Incorrect installation. -refer to Figure 3 to ensure correct location of storm collars. Flames are consis-Unit is over-fired or undertently too large or fired. too small. Carboning occurs. AB -check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7” (minimum 4.5”) water column for natural gas or 3” ( ” minimum) water column for propane. Check that main burner is operating on “HI”. Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5” water column for natural gas or 0” water column for propane. Check that main burner is operating on “HI”. AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLy TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution. Carbon is being deposited on glass, logs or combustion chamber surfaces. White / grey film forms. Air shutter has become -ensure air shutter opening is free of lint or other obstructions. blocked Flame is impinging on the logs or combustion chamber. Sulphur from fuel is being deposited on glass,...
Dieses Handbuch ist für folgende Modelle:Kamine - GD82NT (6.37 mb)