Login:
Stimmen - 3, Durchschnittliche Bewertung: 3 ( )

Anleitung Lennox Hearth, modell KOZY-WORLD KWN109

Hersteller: Lennox Hearth
Dateigröße: 3.2 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. Install sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly. IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. CAUTION: Use pipe joint sealant that is resistant to natural gas. Figure 12 -Gas Connection Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream fro m h eater (s ee F igu re 12 ). 10 Figure 13-Equipment Shutoff Valve INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa) 1. Close equipment shutoff valve (see Figure 13). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 13). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 14 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 10,11 and 12) Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, pages 11 and 12) . 8. Replace lower front panel. OPERATING YOUR HEATER nFOR YOUR SAFETYnREAD BEFORE LIGHTING A. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHAT TO DO IF YOU SMELL GAS l Do not try to light any appliance. l Do not touch any electric switch; do not use any phone in your building. l Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. l If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Figure 14 -Checking Gas Joints WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage personal injury or loss of life. WARNING: Do not over ti g h t en ga s c o n n e c ti o n s. Figure 13-Equipment Shutoff Valve INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will d...

Dieses Handbuch ist für folgende Modelle:
Kamine - KOZY-WORLD KWN109 (3.2 mb)
Kamine - KOZY-WORLD KWN111 (3.2 mb)
Kamine - KOZY-WORLD KWN121 (3.2 mb)
Kamine - KOZY-WORLD KWN111 (3.2 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien