Anleitung Lennox Hearth, modell VF4000-CMP-2

Hersteller: Lennox Hearth
Dateigröße: 1 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Do not install in the vicinity of gasoline or other flammable liquids. The heater must be kept clear and free from these combustible materials and may not be located near where they are stored. Clearances WARNING: DO NOT INSTALL VF SERIES UNVENTED ROOM HEATERS IN SLEEPING QUARTERS, OR IN RECREATIONAL VEHICLES. WARNING: DO NOT INSTALL THE VF UNVENTED ROOM HEATER: • WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM THE FRONT OF THE UNVENTED ROOM HEATER. • IN HIGH TRAFFIC AREAS. • IN WINDY OR DRAFTY AREAS. Ensure the minimum clearances shown in Figures 2 and 3are maintained. Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 37-1/2” (953 mm) Combustible Finished WallMaterialsTop of ApplianceVF Series12" ( mm) 2-1/2" ( mm) 8" ( mm) 26" ( mm) Top of Door FrameSpacer6'' 8'' 10'' 22-1/2" ( mm) 18-5/8" ( mm) 14-1/2" ( mm) Header1/4" GapRequired Figure 2 A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any hearth extensions used is for appearance only and does not have to conform to standard hearth extension installation requirements. Note:Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the appliance front face. 6" Clearance Figure 337-1/2" Min. to Ceiling(953 mm) (See Fig. 2) to CombustibleSide WallMax. Projection (See Fig. 2) CombustibleMantel PREINSTALLATION Check that all listed parts have been received. Carefully inspect the heater case and contents for shipping damage and immediately inform the dealer from whom you purchased the gas fireplace if any damage is found. The appliance is shipped with all gas controls and components installed and pre-wired. Remove the shipping carton. The nailing flanges are installed at each side of the appliance backwards when shipped from the factory to protect the unit from shipping damage. Remove the nailing flanges and retain for use when installing the appliance in framing. Remove three screws and remove the screen panel. Remove the logs and set aside. Check Gas Type This appliance can only be connected to the gas type specified on the appliance data plate. This appliance can not be modified in the field for a different gas type. If the gas type to be used is not the one specified contact the dealer to obtain the correct gas appliance. Note:Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design preferences. However, always maintain minimum clearances to combustible materials and do not violate any specific installation requirements. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Note:The following steps represent the nor...

Dieses Handbuch ist für folgende Modelle:
Kamine - VF4000-CHN-2 (1 mb)
Kamine - VF4000-CHP-2 (1 mb)
Kamine - VF4000-CHN-2 (1 mb)
Kamine - VF4000-CHN-2 (1 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien