Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Desa, modell (V)TC36NE Series, (V)TC36GPE Series

Hersteller: Desa
Dateigröße: 1.97 mb
Dateiname: 54adb313-ffa7-3534-b1ec-47904fd3f899.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26). 6. While supporting speed control, secure control shaft with lock nutby pushing and turning lock nut with pliers clockwise until it istight against front panel. Place control knob provided on shaft. 7. Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16. 8. Plug in blower power cord. a. If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route powercord through exit hole and plug the power cord into a wall receptacle near the firebox. b. If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner.s manual for instructions on wiringthe duplex outlet. CAUTION: Never touch the blower wheel while in operation. 9. Check to make sure that the power cord is completely clear of theblower wheel and that there are no other foreign objects in blowerwheel. Turn blower on and check for operation. Turn blower offby turning knob fully counterclockwise before continuing. 10. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27). Speed Switch Bracket Control Knob Control Control Shaft (Located underneathLocknut Blower Plug-In Duplex Outlet firebox floor against lower right outside wall) Figure 26 -Attaching Speed Control to Firebox Variable Fan Switch White White Black Green On 110/115 V.A.C. BlowerMotor Black Black Black Off Wiring Diagram Decal 12" in Front of Blower Model BKT Installation Note: WheninstallingtheBKTthermostatically-controlledblower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed. 1. Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 28). 2. Connect wire harness and power cord terminals. Connect the blue jumper wire to the blower motor terminal and the rightside terminal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal. Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely. 3. Place the blower against the lower rear wall of the firebox outerwrapper with the exhaust port directed upward and the thermodiscpositioned up near the fireplace bottom. The thermodisc must beoriented near the fireplace bottom as shown in Figure 28, in orderto sense temperature and properly operate.The blower will be heldin position against the back wall by the magnets incorporated ontothe blower housing (see Figure 28). 4. Be certain that all wire terminals are securely attached to terminals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight. Power Cord Blue WireRing Terminal on Green WireWhite WireThermal Switch Air Flow Direction Magnetic Thermal Strips Switch Bracket Black Wire Phillips Screw Air Flow Direction Thermodisc Route BKT Blower Through This Area Magnets Blower Side View Firebox Bottom Location Figure 28 - Blower Model BKT Figure 27 -Location of Wiring Diagram Decal (Model May Vary From Illustration) 116234-01A 18 FIREPLACE INSTALLATION Installing Optional Blower Accessory (Cont.) Installing Gas Piping to Fireplace Location FIREPLACE INSTALLATION Continued 5. Mount the speed control box against the mounting plate providedin the lower fireplace cavity by placing the plastic control shaftforward through the round hole (see Figure 26, page 17). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 26, page 17). 7. Check to make sure that the power cord is completely clear of theblower wheel and that there are no other foreign objects in blowerwheel.Also doublecheck all wire leads and make sure wire routingis not pinched or in a precarious position. Correct accordingly. 8. Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16. 9. Plug in blower power cord to duplex outlet. 10. The blower will only run when the speed control knob is in theON position and the thermal switch senses temperature after thefireplace begins to heat up. The blower speed can be adjusted byrotating the controlknob. To turn off,turn knob fully counterclockwise until it clicks off. If the blower is ON and has...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien