Anleitung Zusammenfassung


11.0” w.c. Inlet Maximum 10.5” w.c. 13.0” w.c. Manifold Pressure 3.5” w.c. 10.0” w.c. Gas Specifications & ORIFICE SIZE Max.Input Min. Input Orifice Model Fuel BTU/h BTU/h Size BLDV400NV7 Nat. 26,000 21,000 2.5 mm BLDV400PV7 LP 26,000 21,000 1/16 in. BLDV400NSC7 Nat. 26,000 19,000 2.5 mm BLDV400PSC7 LP 26,000 21,000 1/16 in. BLDV500NV7 Nat. 28,000 20,000 #38 BLDV500PV7 LP 27,000 22,000 1.55 mm BLDV500NSC7 Nat. 28,000 20,000 #38 BLDV500PSC7 LP 27,000 22,000 1.55 mm Ignitor On/Off/RS Switch Hi/Lo Knob FP2073 Off/Pilot/On Knob Figure 1 - BLDV7 Series Fireplace (Millivolt Control shown) pRE-INSTALLATION INFORMATION R - Rough Opening WidthRoughOpeningHeightRoughOpeningDepthABCDEFGHIJKLMNOVQUTP743000BLDV 7 dimsOVS1/2” or 5/8” (13 or 16 mm) 7" Dia. 4" Dia. Figure 2 - Fireplace Specifications and Framing Dimensions Gas Line Access BLDV400 BLDV500 A 37Z\zn" (941 mm) 41Z\zn" (1043 mm) B 29" (737 mm) 33" (838 mm) C 40B\," (1032 mm) 40B\," (1032 mm) D 30Z\v" (768 mm) 34Z\v" (870 mm) E 17>\zn" (446 mm) 17>\zn" (446 mm) F 25ZC\zn" (656 mm) 25ZC\zn" (656 mm) G 31M\," (810 mm) 31M\," (810 mm) H 31ZB\zn" (811 mm) 35ZB\zn" (913 mm) I 3" (76 mm) 3" (76 mm) J 1" (25 mm) 1" (25 mm) K 11C\," (289 mm) 11C\," (289 mm) L 15/16" (24 mm) 15/16" (24 mm) M 15Z\," (384 mm) 17Z\," (435 mm) N 7B\zm" (186 mm) 7B\zm" (186 mm) O 2>\zn" (65 mm) 2>\zn" (65 mm) P 7C\v" (197 mm) 7C\v" (197 mm) Framing Dimensions Q 41C\v" (1060 mm) 41C\v" (1060 mm) R 37M\zn" (951 mm) 41M\zn" (1053 mm) S 17Z\zn" (433 mm) 17Z\zn" (433 mm) T 64C\v" (1645 mm) 68C\v" (1746 mm) U 32C\," (822 mm) 34C\," (873 mm) V 45ZC\zn" (1164 mm) 48B\," (1235 mm) pre-installation information Before You Start Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following: • Fireplace (Firebox and Burner System) • Rock Wool • Log Set Items Required For Installation • Phillips Screwdriver • Framing Materials • Hammer • Wall Finishing Materials • Saw and/or saber saw • Level • Electric Drill and Bits • Tee Joint • Pliers • Measuring Tape • Square • Pipe Wrench • Caulking Material (Noncombustible) • Fireplace Surround Material (Noncombustible) • Piping Complying with Local Codes • Pipe Sealant Approved for use with Propane/LPG (Resistant to Sulfur Compounds) firebox framing Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 for your specific installation requirements. Refer to Figure 2 for firebox dimensions. The framing headers may rest on the top of the firebox standoffs. Do not bring headers below top of standoffs. NOTE: When planning your framing and installation, keep in mind that your gas line will come in on the right side of the box (as you are facing it) and your electricity will come in on the left side. The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure. WARNING Do not fill spaces around firebox with insulation or other materials. This could cause a fire. NOTE Cold Climate Insulation If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and under the floor on which the appliance rests, if the floor is above ground level. pRE-INSTALLATION INFORMATION Fireplace Location Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections. The following factors should be taken into consideration: • Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to combustibles must be maintained. • This fireplace may be installed along a wall, across a corner, or use an exterior chase. Refer to Figure 3 for suggested locations. • Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance. • Never obstruct the front opening of the fireplace. • Do not install in the vicinity where gasoline or other flammable liquids may be stored. • Vent pipe routing. Refer to Venting section found in this manual for allowable venting configurations. • These units can be installed in a bedroom. Refer to National Fuel Gas Code ANSI ...

Dieses Handbuch ist für folgende Modelle:
Kamine - N/PSC7 (6.77 mb)
Kamine - BLDV7 SERIES BLDV500N/PV7 (6.77 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien