Login:
heruntergeladen wurde: 0   Dateigröße: 388 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

e. Thermocouple defective - replace. f. Gas control defective - replace. 4. Main burner does not ignite. a. Main burner orifice is blocked - clean, see "Appliance Maintenance," above. Inlet gas pressure too low, contact gas supplier. 5. Heater keeps shutting "OFF" during normal operation. a. Pilot is blocked - clean pilot, see Page 11. b. Inlet gas pressure too low, contact gas supplier Page 12 R-2688 PARTS LIST PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number a

heruntergeladen wurde: 3   Dateigröße: 561 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer,

heruntergeladen wurde: 2   Dateigröße: 561 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

9. Open tees should not be used in the flue pipe. 10. Appliance must not be connected to a chimney flue that is servicing a separate solid-fuel burning appliance. For proper venting, do not attach a 90° elbow directly to draft diverter. If possible, attach 2 feet (.6m) of straight vent pipe before an elbow is used. Use 45° elbows if possible. Uninsulated single-wall metal pipe shall not be used outdoors in cold climates for venting gas utilization equipment. Ventilation and Combustion Air Room h

heruntergeladen wurde: 4   Dateigröße: 608 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

3. Remove lower louver from casing assembly (2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Inspect interior of casing assembly for accumulation of dust, lint or spider webs. If necessary, clean interior of casing assembly with a vacuum cleaner or apply air pressure. Do not damage any components within casing assembly when you are cleaning. 6. Remove main burner orifice from orifice holder. 7. Apply air pressure through main burner orifice and orifice holder to remove dust, l

heruntergeladen wurde: 0   Dateigröße: 608 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, t

heruntergeladen wurde: 1   Dateigröße: 608 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

Consumer: Please retain these instructions for future use. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. . Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. . WHAT TO DO IF YOU SMELL GAS . Do not try to light any appliance. . Do not touch any electrical switch; do not use any phone in your building. . Immediately call your

heruntergeladen wurde: 8   Dateigröße: 844 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

(Strong winds, dirty pilot and low pressure will reduce readings.) Piezo Pilot Ignitor Instructions Depressing the button completely causes a spark to occur at the pilot. This is a substitute for a match which requires opening the pilot hole cover. To light the pilot, it is important that the electrode be 1/8" (3mm) from the thermopile. The spark must occur at the point the burner flame hits the thermopile. The end of the electrode will be red hot with the pilot on. On a new installation with ai

heruntergeladen wurde: 1   Dateigröße: 844 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

In case of regulator malfunction, the six (6) (1.83m) feet distance will reduce the chance of gas entering the vent cap. Location of Furnace Pick a location on an outside wall with a clear space of 28" (711mm) high by 49" (124cm) wide in the room. Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The wall studs can be used for attachment of wall mounting bracket. The wall opening required as shown in

heruntergeladen wurde: 0   Dateigröße: 996 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

circulating air passageways of the appliance be kept clean. • Due to high temperatures, the appliance should be located • DO NOT use this room heater if any part has been under out of traffic and away from furniture and draperies. water. Immediately call a qualified service technician to • Children and adults should be alerted to the hazard of inspect the room heater and to replace any part of the high surface temperature and should stay away to avoid control system and any gas control which has

heruntergeladen wurde: 3   Dateigröße: 996 kb   Hersteller: Empire Products  
Kategorie: elektrische Heizungen
@name

Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 16009-1-0504 PARTS LIST PARTS LIST SR-18T SR-30T PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART NUMBER NUMBER DESCRIPTION NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBLY - LEFT 1 13348 CASING SIDE ASSEMBLY - LEFT 2 SR-090 CASING BACK 2 SR-041 CASING BACK 3 R-2313 PIEZO IGNITOR 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBLY - RIGHT 4 SR-008 CASI