|
Anleitung Zusammenfassung
Clean with emery cloth or replace as required. 10. Verify millivolt output. Replace as necessary. Venting 1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc. 2. Confirm that termination cap remains clear and unobstructed by plants, etc. 3. Verify that termination cap clearance to subsequent construction (building additions, decks, fences or sheds) has been maintained. 4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and flashing remains intact. Remote Controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Page 43 Page 44 Quadra-Fire · Garnet-T · 7016-127F September 1, 2008 12 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For clearances refer to Section 3. Figure 12.1 Appliance Dimensions A B F C D E Location Inches Millimeter Location Inches Millimeter A 27-3/4 705 D 17-3/8 441 B 17-7/8 454 E 23-5/8 600 C 15-3/8 391 F 17-3/4 451 B. Vent Components Diagram 6-3/8 in. 9-1/4 in. (235mm) (162mm) 6-1/2 in. (165mm) 6-5/8 in. (168mm) SLP45-BK SLP90M (244mm) 9-5/8 in. (244mm) 6-5/8 in. (168mm) 6-1/2 in. (165mm) 6-3/8 in. (162mm) 9-5/8 in. 17-24 in. 6-1/2 in. (432-610mm) 11-3/4 in. (298mm) 5-3/4 in. (146mm) 6-5/8 in. (165mm) (168mm) SLP12AM SLP12M SLP6M 47-3/4 in. (1213mm) 35-3/4 in. (908mm) 23-3/4 in. (603mm) 12-17 in. (305-432mm) 3-3/4 in. (95mm) SLP4M SLP6AM SLP24M SLP36M SLP48M 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe Figure 12.2 SL-D Series Vent Components September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Page 45 C. Vent Components List Description HHT SL-P M= Multi Pack (6) Simpson Dura-Vent DirectVent Pro ® Selkirk Direct-Temp ® Amerivent Direct ® Security Secure Vent® 4” Pipe Length, Galvanized SLP4M ---- 4” Pipe Length, Black SLP4-BK ---- 6” Pipe Length, Galvanized SLP6M 46-DVA-06 4DT-6 -SV4L6 6” Pipe Length, Black SLP6-BK 46-DVA-06B 4DT-6B -SV4LB6 7” Pipe Length, Galvanized ---4D7 - 7” Pipe Length, Black ---4D7B - 9” Pipe Length, Galvanized -46-DVA-09 4DT-9 -- 9” Pipe Length, Black -46-DVA-09B 4DT-9B -- 12” Pipe Length, Galvanized SLP12M 46-DVA-12 4DT-12 4D12 SV4L12 12” Pipe Length, Black SLP12-BK 46-DVA-12B 4DT-12B 4D12B SV4LB12 18” Pipe Length, Galvanized -46-DVA-18 4DT-18 -- 18” Pipe Length, Black -46-DVA-18B 4DT-18B -- 24” Pipe Length, Galvanized SLP24M 46-DVA-24 4DT-24 4D2 SV4L24 24” Pipe Length, Black SLP24-BK 46-DVA-24B 4DT-24B 4D2B SV4LB24 36” Pipe Length, Galvanized SLP36M 46-DVA-36 4DT-36 4D3 SV4L36 36” Pipe Length, Black SLP36-BK 46-DVA-36B 4DT-36B 4D3B SV4LB36 48” Pipe Length, Galvanized SLP48M 46-DVA-48 4DT-48 4D4 SV4L48 48” Pipe Length, Black SLP48-BK 46-DVA-48B 4DT-48B 4D4B SV4LB48 Adjustable Length, 3”-6”, Black SLP6A-BK --- Adjustable Length, 3”-6”, Galvanized SLP6AM ---- Adjustable Length, 3”-7”, Galvanized -46DVA-08A --- Adjustable Length, 3”-7”, Black -46DVA-08AB --- Adjustable Length, 3”-12”, Black SLP12A-BK ---- Adjustable Length, 3”-12”, Galvanized SLP12AM ---- Adjustable Length, 3”-14.5”, Galvanized -46DVA-16A --- Adjustable Length, 3”-14.5”, Black -46DVA-16AB --- Adjustable Length, 7”, Galvanized ---4D7A - Adjustable Length, 7”, Black ---4F7AB - Adjustable Length, 11”-14”, Galvanized --4DT-AJ -- Adjustable Length, 11”-14”, Black --4DT-AJB -- Adjustable Length, 12”, Galvanized -4DTAJ12 -4D12A SV4LA12 Adjustable Length, 12”, Black -4DTAJ12-B -4D12AB SV4LBA12 Adjustable Length, 16”, Galvanized -46DVA-16A -4D16A - Adjustable Length, 16”, Black -46DVA-16AB --- Adjustable Length, 24”, Galvanized ----SV4LA24 Adjustable Length, 24”, Black ----SV4LBA24 2’ Flexible Pipe Length SLP-FLEX-2 ---- 3’ Flexible Pipe Length SLP-FLEX-3 ---- 5’ Flexible Pipe Length SLP-FLEX-5 ---- 10’ Flexible Pipe Length SLP-FLEX-10 ---- 3” x 35’ Flex Extension -2280 --- 4” x 35’ Flex Extension -2281 --- 45° Elbow, Galvanized SLP45M ---- 45° Elbow, Black SLP45-BK See Swivel 4DT-EL45B 4D45LB SV4EBR45 45° Elbow, Swivel, Galvanized -46DVA-E45 --SV4E45 Page 46 Quadra-Fire · Garnet-T · 7016-127F September 1, 2008 45° Elbow, Swivel, Black -46DVA-E45B --SV4EB45 90° Elbow, Galvanized SLP90M See Swivel 4DT-EL905 4D90LS - 90° Elbow, Black SLP90-BK See Swivel 4DT-EL90SB 4D90LBS SV4EBR90 90° Elbow, Swivel, Galvanized -46DVA-E90 --SV4E90 90° Elbow, Swivel, Black -46DVA-E90B --SV4EB90 Adjustable Flashing, 0/12-6/12 SLP-RF6M 46DVA-F6 4DT-AF6 4DF SV4FA Adjustable Flashing, 7/12-12/12 SLP-RF12M 46DVA-F12 4DT-AF12 4DF12 SV4FB Attic Insulation Shield - Cold Climates 36” ---4DAIS37 - Attic Insulation Shield 12” SLP-AS2M --4DAIS12 SV4RSA Attic Insulation Shield, Adjustable 11”-20” -46-DVA-IS --- Cathedral Support Box SLP-CCS-BK 46DVA-CS 4DT-CSS 4DRSB SV4CSB Ceiling Support -46DVA-DC 4DT-CS 4DFSP SV4SD Co-Axial to Co-Lineal Appliance Connector -46DVA-GCL --- Decorative Ceiling Firestop - Black SLP-DCF-BK ---- Decorative Radius Cover DRC-RADIUS ---- Firestop Spacer/Ceiling Firestop SLP...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - GARNET-T GARNET-D-CWL (3.18 mb)
elektrische Heizungen - GARNET-T GARNET-D-MBK (3.18 mb)
elektrische Heizungen - GARNET-T GARNET-D-PMH (3.18 mb)
elektrische Heizungen - GARNET-T GARNET-MBK (3.18 mb)