Anleitung Bryant, modell DURAPAC PLUS 581A

Hersteller: Bryant
Dateigröße: 2.71 mb
Dateiname: ii581a-210-2.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


wg)* COMPONENT CFM 4,000 4,500 5,000 5,500 6,000 6,500 7,000 7,500 8,000 8,500 9,000 9,500 10,000 10,500 11,000 11,500 12,000 EconoMi$er IV 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.13 0.15 0.16 0.17 0.19 0.20 LEGEND FIOP — Factory-Installed Option *The static pressure must be added to the external static pressure. The sum and the evaporator entering-air cfm should then be used in conjunction with the Fan Performance tables to determine blower rpm and watts. Table 27 — Fan Rpm at Motor Pulley Settings* 581A UNIT SIZE DRIVE MOTOR PULLEY TURNS OPEN 0 1/2 1 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6 210 (208/230 and 460 volt) Low Range Vertical 647 667 687 707 727 747 767 786 806 826 846 866 886 High Range Vertical 897 917 937 958 978 998 1018 1038 1058 1079 1099 1119 1139 Low Range Horizontal 896 924 951 979 1006 1034 1062 1089 1117 1144 1172 1199 1227 High Range Horizontal 1113 1138 1163 1188 1213 1238 1264 1289 1314 1339 1364 1389 1414 210 (575 volt) Low Range Vertical 810 832 854 876 897 919 941 963 985 1007 1028 1050 1072 High Range Vertical 873 893 912 932 951 971 991 1010 1030 1049 1069 1088 1108 Low Range Horizontal 863 886 909 933 956 979 1002 1025 1048 1072 1095 1118 1141 High Range Horizontal 1042 1062 1083 1103 1123 1143 1164 1184 1204 1224 1245 1265 1285 240 (208/230 and 460 volt) Low Range Vertical 949 970 992 1013 1035 1056 1078 1099 1120 1142 1163 1185 1206 High Range Vertical 941 961 980 1000 1019 1039 1059 1078 1098 1117 1137 1156 1176 Low Range Horizontal 1113 1138 1163 1188 1213 1238 1264 1289 1314 1339 1364 1389 1414 High Range Horizontal 1096 1116 1137 1157 1177 1197 1218 1238 1258 1278 1299 1319 1339 240 (575 volt) Low Range Vertical 949 970 992 1013 1035 1056 1078 1099 1120 1142 1163 1185 1206 High Range Vertical 941 961 980 1000 1019 1039 1059 1078 1098 1117 1137 1156 1176 Low Range Horizontal 1113 1138 1163 1188 1213 1238 1264 1289 1314 1339 1364 1389 1414 High Range Horizontal 1096 1116 1137 1157 1177 1197 1218 1238 1258 1278 1299 1319 1339 300 (all voltages) Low Range Vertical 941 961 980 1000 1019 1039 1059 1078 1098 1117 1137 1156 1176 High Range Vertical 1014 1038 1061 1085 1108 1132 1156 1179 1203 1226 1250 1273 1297 Low Range Horizontal 941 961 980 1000 1019 1039 1059 1078 1098 1117 1137 1156 1176 High Range Horizontal 1014 1038 1061 1085 1108 1132 1156 1179 1203 1226 1250 1273 1297 *Approximate fan rpm shown. XII. OPTIONAL ECONOMI$ER IV See Fig. 23 for EconoMi$er IV component locations. The optional EconoMi$er IV comes from the factory fully wired and assembled. No field wiring or assembly is required for standard outdoor dry bulb changeover operation. Field wiring of accessory sensors is required for different operational modes. A. EconoMi$er IV Standard Sensors Outdoor Air Temperature (OAT) Sensor The outdoor air temperature sensor (HH57AC074) is a 10 to 20 mA device used to measure the outdoor-air temperature. The outdoor-air temperature is used to determine when the EconoMi$er IV can be used for free cooling. The sensor is factory-installed on the EconoMi$er IV in the outdoor airstream. See Fig. 23. The operating range of temperature measurement is 40 to 100 F. Supply-Air Temperature (SAT) Sensor The supply-air temperature sensor is a 3 K thermistor located at the outlet of the indoor fan. See Fig. 24. This sen sor is factory installed. The operating range of temperature measurement is 0° to 158 F. The temperature sensor is a short probe with blue wires running to it. Outdoor Air Lockout Sensor The EconoMi$er IV is equipped with an ambient temperature lockout switch located in the outdoor airstream which is used to lock out the compressors below a 42 F ambient temperature. B. EconoMi$er IV Controller Wiring and Operational Modes Determine the EconoMi$er IV control mode before set up of the control. Some modes of operation may require different sensors. Refer to Table 28. The EconoMi$er IV is supplied from the factory with a supply-air temperature sensor and an outdoor air temperature sensor. This allows for operation of the EconoMi$er IV with outdoor air dry bulb changeover control. Additional accessories can be added to allow for different types of changeover control and operation of the EconoMi$er IV and unit. Outdoor Dry Bulb Changeover The standard controller is shipped from the factory configured for outdoor dry bulb changeover control. The outdoor air and supply-air temperature sensors are included as standard. For this control mode, the outdoor temperature is compared to an adjustable set point selected on the control. If the outdoor-air temperature is above the set point, the EconoMi$er IV will adjust the outdoor-air dampers to minimum position. If the outdoor-air temperature is below the set point, the position of the outdoor-air dampers will be controlled to provide free cooling using outdoor air. When in this mode, the LED next to the free cooling set point potentiometer will be on. The changeover temperature set point is controlled by the free cooling se...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien