Anleitung Zusammenfassung


The heater should only be operated in the upright position • The heater should be positioned in accordance to the clearances stated in these instructions • DO NOT locate this heater immediately beneath a fixed socket outlet General The Calidou radiator is designed to provide exceptional levels of comfort with a combination of radiant and convected heat in both domestic and commercial applications. Wall Mounting / Installation The heater should be positioned observing the minimum clearances stated around the heater. (see also ‘Electrical’ section) The wall bracket supplied with the heater must be used 1. Using a screwdriver, turn the latch in a clockwise direction to unlatch the bracket, then remove it from the appliance (see Fig.1) 2. Mount the bracket on the wall using a minimum of 4 screws (max diameter 6mm) making sure that it is the correct way up and at the correct height. (see Fig.2) 3. Position the appliance on the bracket. 4. Re-latch the bracket turning the latch anti-clockwise. Fig. 2 Fig.1 Model A (mm B (mm) CAL075 140 228 CAL100 300 234 CAL150 400 242 CAL200 700 27 Electrical The wires in the mains lead are coloured in accordance with the following code: If the wall is a light partition or crumbling, then supporting legs GREEN & YELLOW EARTH are also needed BLUE NEUTRAL (Part No. CAL0001). The heater MUST be fitted to the wall as BROWN LIVE well as having the supporting legs BLACK PILOT WIRE (See also ‘Pilot Wire Connection’) The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises through a suitable connection box positioned adjacent to the heater. The supply circuit to each heater must incorporate a double pole isolating switch having a contact separation of at least 3mm Pilot Wire Connection The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex programmers. If, however a programmer is not being used, the pilot wire should be isolated in accordance with the current IEE Wiring Regulations. IMPORTANT - Do NOT connect the BLACK pilot wire to earth Care should be taken with the installation of the pilot wire(s) as when switching to background (set back) they become energised at 240V although only at a current of 1mA. 1. Place the legs under the heater In every case a suitable means of isolation must be provided for the pilot wire and marked to 2. Position the hinges into the grooves in the air inlet indicate that two sources of supply may be present at the heater. 3. Unscrew the jacks, until they reach the floor Where pilot wires are installed separately from the heater final sub-circuit they should be protected, double insulated and carry their own integral earth continuity conductor. Operation Mode Selection Dial (A) Use this rotary dial to select the function you require Symbol Function Description Frost Protection Heater will switch on to provide frost protection if the room drops below 5.C Background (set back) Heater will maintain a lower temperatur...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - CAL200 (239.59 kb)
elektrische Heizungen - CAL100 (239.59 kb)
elektrische Heizungen - CAL150 (239.59 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien