Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Cadet, modell P)-2

Hersteller: Cadet
Dateigröße: 4.86 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 1. Stop! Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 5. Lower louver front assembly. 6. Turn gas control knob clockwise to "OFF." 7. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step. 8. Turn gas control knob counterclockwise to "ON". 9. Close louver front assembly. 10. Turn on all electric power to the appliance. 11. Set thermostat to desired setting. 12. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" and call your service technician or gas supplier. GAS CONTROL KNOB SHOWN IN "OFF” POSITION. ON HONEYWELL OFF LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1. Set the thermostat to lowest setting. (if applicable.) 2. Turn off all electric power to the appliance if service is to be performed. 3. Open bottom louver assembly. 4. Turn gas control knob clockwise to "OFF". Do not force. 5. Close bottom louver assembly. Page 52 21759-6-0608 INTERMITTENT PILOT TROUBLESHOOTING Call Serviceman GENERAL: Allfireplaceshavebeenfire-testedtocheck forproper operation. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation. If the fireplace fails to function on initial installation, it is advisable to re-check the following: 1. 115 volts to the junction box. 2. Inlet gas pressure. 3. The 24 volt system. 4. Type of gas being used and that shown on the rating label. The Service Department at Empire Comfort Systems, Inc. may be contacted to assist in servicing furnace. Servicing the Pilot and Main Burners, Pilot Orifice, and Main Burner Orifices: Disconnect the gas supply at the inlet to the control valve. Then remove the burner door to which the above components are attached. S8600H INTERMITTENT IGNITION MODULE SPECIFICATIONS Lockout timing is 90 seconds. Ignition timing is until pilot lights or lockout occurs. Module shuts down and cuts power to gas control on flame failure. Gas control closes to provide 100 percent lockout on flame failure. Manual reset required. ELECTRICAL RATINGS: Voltage and frequency: 20.5 to 28.5V (24V nom.) 60 Hz. Current rating: 0.2 A. Valve contact ratings (at 24 Vac): Run Inrush Pilot 1.0 A 10.0 A Main 1.0 A 10.0 A SPARK GENERATOR OUTPUT: 13kV peak at 25 pf load. THERMOSTATANTICIPATOR SETTING: 0.2 Aplus pilot valve rating plus main valve rating. THERMOSTAT COMPATIBILITY: Standard models compatible with all open-close switch type 24 Vac thermostats capable of supplying rated voltage and current to the module. AMBIENT TEMPERATURE RATING: Minus 40 F to plus 175 F (minus 40 C to plus 79 C). RELATIVE HUMIDITY RATING: 5 to 90 percent RH at 95 F. FLAME FAILURE RESPONSE TIME: 0.8 seconds at 1.0 uA flame current. FLAME CURRENT: 1 uA, min. CHECKOUT Check out the gas control system: 1. At initial installation of the appliance. 2. As part of regular maintenance procedures. 3. As the first step in troubleshooting. 4. Any time work is done on the system. STEP 1: Perform Visual Inspection. A. With power off, make sure all wiring connections are clean and tight. B. Turn on power to appliance and ignition module. C. Open manual shutoff valves in the gas line to the appliance. D. Do gas leak test ahead of gas control if piping has been disturbed. Gas Leak Test: Paint pipe joints with rich soap and water solution. Bubbles indicate gas leak. Tighten joints to stop leak. STEP 2: Review Normal Operating Sequence and Module Specifications. STEP 3: Reset the Module. A. Turn the thermostat to its lowest setting. B. Wait one minute. As you do Steps 4 and 5, watch for points where operation deviates from normal. Refer to Troubleshooting Chart to correct problem. STEP 4: Check Safety Lockout Operation. A. Turn gas supply off. B. Set thermostat above room temperature to call for heat. C. Watch for spark at pilot burner. D. Time length of spark operation. Maximum spark time is 90 seconds. E. Open manual gas cock and make sure no gas is flowing to pilot or main burner. F. Set thermostat below room temperature and wait one minute before continuing. STEP 5: Check Normal Operation. A. Set thermostat above room temperature to call for heat. B. Make sure pilot lights smoothly when gas reaches the pilot burner. C. Makesuremainburnerlightssmoothlywithoutflashback. Make sure burner operates smoothly without floating or lifting. D. If gas line has been disturbed, complete gas leak test. G...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - DVP42FP (4.86 mb)
elektrische Heizungen - DVP42FP (4.86 mb)
elektrische Heizungen - P)-2 (4.86 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien