Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Cadet, modell DVP42FP

Hersteller: Cadet
Dateigröße: 4.86 mb
Dateiname: 4e1880de-91ce-7514-dd6f-969c96c78167.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Only non-combustible materials may be used to cover the black fireplace front. Warning: When finishing the fireplace never obstruct or modify the air inlet/outlet louvers in any manner. Provide adequate clearances around air openings into the combustion chamber. Caution: If the joints between the finished wall and the fireplace surround (top and sides) are sealed, a 300°F minimum sealant material must be used. These joints are not required to be sealed. Only non-combustible material (using 300°F minimum adhesive if needed), can be applied as facing to the fireplace surround. Page 12 21759-6-0608 21759-6-0608 Page 13 Flush Wall Installation Figure 12 Combustible Surround Installation Figure 13 Vent Runs (Figures 14, 15, 16, 17 and 18) In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed. These include the direct vent system, gas piping for the appliance and the electrical wiring. (If the fan option is used.) The appliance can be mounted on any of the following surfaces: 1. A flat, hard combustible (burnable) surface. 2. A raised wooden platform. 3. Four (4) corner supports. (Example: Four (4) concrete masonry blocks.) These supports must be positioned so they contact all four (4) perimeter edges on the bottom of the unit. VERTICAL, 90° ELBOW WITH HORIZONTAL TERMINATION Figure 14 3! OF NON-COMBUSTIBLE MATERIAL FINISHED WALL FRONT TRIM OR NONCOMBUSTIBLE MA TERIAL (INSTALLA TION IS OPTIONAL) JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F, 149° C SEALANT MATERIAL (SEALANT IS OPTIONAL) DVP42, 48 49 .”(126 mm) TO BOTTOM OF UNIT VENT CAP/ THIMBLE 3! OF NON-COMBUSTIBLE MATERIAL FINISHED WALL FRONT TRIM OR NON-COMBUSTIBLE MATERIAL (INSTALLATION IS OPTIONAL) JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F 149 MATERIAL (SEALANT IS OPTIONAL) ° C SEALANT COMBUSTIBLE SURROUND MANTELSHELF 2 X 4 HEADER STAND OFF / THIMBLE Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insulation codes. INSTALLATION (continued) HORIZONTAL ONLY, STRAIGHT OUT THE BACK CORNER INSTALLATION VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL "A" WALL FIRESTOP/ PIPE LENGTH VENT CAP WALL FIRESTOP/ THIMBLE VENTCAPTHIMBLE "A" "B" MODEL 6"(152mm) 5 1/8"(130mm) to 6 /2"(165mm) DVP 42,48 9"(229mm) 8 1/8"(206mm) to 91/2"(241mm) DVP 42 12"(305mm) 11 1/8"(283mm) to 12 1/2"(317mm) DVP 42 Figure 15 VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL Figure 17 Dim. DVP42 DVP48 A 45 3/8" 1152mm 49 5/8" 1260mm B 32 1/8" 816mm 35 1/8" 892mm C 13 3/8" 34 mm 15 1/2" 39 mm D 64 1/8" 1628mm 70 1/8" 1781mm WALLFIRESTOP/ THIMBLE CORNER INSTALLATION HORIZONTAL, 45° ELBOW TO HORIZONTAL OUT THE WALL WALLFIRESTOP/ THIMBLE "A" "B" "C" 6"(152mm) 11 1/4"(286mm) to 12 3/4"(324mm) 4 3/4"(121mm) to 6 1/4"(159mm) 9"(229mm) 14 1/4"(362mm) to 15 3/4"(400mm) 7 3/4"(197mm) to 9 1/4"(235MM) 12"(305mm) 17 1/4"(438mm) to 18 3/4"(476mm) 10 3/4"(273mm) to 12 1/4"(311mm) DVP42 DVP48 "A" "B" "B" 6"(152mm) 4"(102mm) to 5 1/2"(140mm) 4"(102mm) to 5"(127mm) 9"(229mm) 6"(152mm) to 7 /2"(191mm) 6"(152mm) to 7 1/2"(191mm) 12"(305mm) 9"(229mm) to 10 1/2"(267mm) 9"(229mm) to 10 1/2"(267mm) Figure 16 Figure 18 Page 14 21759-6-0608 VENTING FIREPLACE - TOP Venting Graph (Dimensions in Feet) To Use the Vent Graph (Figure 19) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the unit in accordance with same. EXAMPLE A: If the vertical dimension from the floor of the unit is 35 feet, the horizontal run to the outer wall flange must not exceed 6.5 feet. EXAMPLE B: If the vertical dimension from the floor of the unit is 6.5 feet, the horizontal run to the outer wall flange must not exceed 14.5 feet. Special Note: For each 45 degree elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18" (45cm). This does not apply if the 45 degree elbows are installed on the vertical part of the vent system. Reduce 3' for every 90° elbow. Example: According to the chart the maximum horizontal vent length is 20' and if two 45 degree elbows are required in the horizontal vent it must be reduced to 17'. The maximum number of 45 degree elbows permitted per sidewallinstallationistwo(2).Theseelbows canbe installed in either the vertical or horizontal run. Note: On vertical venting the first elbow does not get counted. VERTICALDIMENSIONFROMTHEBOTTOMOFTHEUNITTOTHECENTEROFTHEFLUEOUTLETWITHVERTICALORHORIZONTALTERMINATIONCAPS Figure 19 Acceptable vertical and horizontal vent run. (40' maximum vertical and 20' maximum horizontal) Unacceptable vertical and horizontal vent run. 21759-6-06...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - DVP42FP (4.86 mb)
elektrische Heizungen - P)-2 (4.86 mb)
elektrische Heizungen - P)-2 (4.86 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien