Hersteller: Well Traveled Living
Dateigröße: 1.45 mb
Dateiname:
|
Anleitung Zusammenfassung
This heater must be placed on level, firm ground. Never operate in an explosive atmosphere. Keep away from areas where gasoline or other flammable liquids or vapors are stored or used. - 15 MAINTENANCE MAINTENANCE WARNING FOR YOUR SAFETY: ALLOW HEATER TO COMPLETELY COOL BEFORE MOVING. CLEANING AND MAINTENANCE To enjoy years of outstanding performance from your Heater, make sure you perform the following maintenance on a regular basis: 1. Keep exterior surfaces clean. Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents. While cleaning your heater, be sure to keep the area around the burner and pilot assembly dry at all times. If the gas control is exposed to water in any way, DO NOT try to use it--it must be replaced. 2. Keep the heater area free and clean from combustible materials, gasoline or other flammable vapors and liquids. Visually check burner flames. Visually check the hose assembly inside the panels and check for cracks or worn sections. 1) Unscrew gas hose and regulator hose with 3/4’’ inch open end wrench and adjustable wrench. 2) Check if there are cracks or worn sections on hose. If yes, contact your gas supplier to replace the hose. 3) At least once a year, the unit should be inspected for the presence of spiders, spider webs or other insects. Air flow must be unobstructed. Keep controls, burner, and circulating air passageways clean. Signs of possible blockage include: 1. Gas odor with extreme yellow tipping of flame. 2. Heater does not reach the desired temperature 3. Heater glow is excessively uneven. 4. Heater makes uneven popping noise. Spiders and insects can nest in burner or orifices. This dangerous condition can damage the heater and render it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear away smaller particles. - 16 MAINTENANCE MAINTENANCE Carbon deposits may create a fire hazard. Clean dome and engine with warm soapy water if any carbon deposits develop. NOTE: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal. If the heater is exposed to this type of environment, you should frequently check for corroded areas and repair them promptly - 17 TROUBLESHOOTING TROUBLESHOOTING Problem Problem cause solution Pilot will not light Gas valve may be OFF Turn the gas valve ON Tank fuel empty Refill LPG tank Air in supply system Purge air from lines Loose connection Check all fittings Pilot will not stay on Debris around pilot Clean dirty area Loose connection Tighten connection Thermocouple bad Replace thermocouple Gas leak in line Check connections Lack of fuel pressure Fuel tank is near empty Burner will no light Pressure is low Fuel tank is near empty Control valve not ON Turn valve to ON Thermocouple bad Replace thermocouple Pilot light assembly bent or not in correct location Place pilot in proper position and retry Manufacturer: Changzhou Wellife Furnace Co.,Ltd Tel: 86-519-83310111 Fax: 86-519-83311577 Distributed By: Well Travel...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - 01337 (1.45 mb)
elektrische Heizungen - 60789 (1.45 mb)
elektrische Heizungen - 60790 (1.45 mb)
elektrische Heizungen - PH-09S (1.45 mb)