Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Gas-Fired Products, modell LTU 125

Hersteller: Gas-Fired Products
Dateigröße: 1.33 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


of Pipe ■ Maximum Equivalent Length - 75 ft. of Pipe NOTE: To minimize problems associated with condensation in long horizontal runs, vent pipe can be insulated. 3. When venting through a sidewall, the horizontal vent pipe shall rise not less than 1/4 inch per foot from the start of the vent system to the vent terminal. All portions of the vent pipe shall be supported to prevent sagging. 4. A minimum clearance of 6 inches must be maintained between the outside wall and vent cap. 5. The horizontal venting system shall not terminate: a. Less than 4 ft. (1.2m) below, 4 ft. (1.2m) horizontally from or 1 ft. (30cm) above any door, window or gravity air inlet into any building. The bottom of the vent terminal shall be located at least 7 ft. (2.1m) above grade or above snow accumulation level as determined by local codes. b. Less than 3 ft. (0.9m) from a combustion air inlet. c. Less than 3 ft. (0.9m) from any other building opening or any gas service regulator. d. Directly over areas where condensate or vapor could create a nuisance or hazard or be harmful to the operation of gas utility meters, regulators, relief valves, or other equipment. Building materials should be protected from flue gases and condensate. 6. In regions of the country where prevailing winds are consistently higher than 40 mph, it may be necessary to terminate the vent system above the roof level. MULTIPLE HEATER VENTING (CONNECTIONS INTO A COMMON VENT OR MANIFOLD) Requirements for venting of multiple heaters are the same as described for SINGLE HEATER VENTING except as follows: 1. The common vent size and total vent height is normally determined by the number of heaters per common vent, length of horizontal connector runs, and connector rise. Connector lengths should be as short as possible and have a minimum W per ft. rise. Without regard to connector rise and total vent height due to many possible venting configurations, the following should be observed: a. Common vent pipe & vent connector diameter should be no less than that shown in the following Vent SizingTable. b. The connector length should be no more than 75% of the vertical portion of vent above the connector. c. Where possible, use a Y-connector to the common vent. -14- Form #43155010 Feb-04 2. Material for connectors should be constructed of galvanized sheet metal or other approved noncombustible corrosion resistant material as allowed by state or local codes. All common vent pipe should be double wall, Type B vent. 3. Avoid unnecessary bends. Limit to two (2) 90° elbows. 4. The entire length of vent connector shall be readily accessible for inspection, cleaning and replacement. 5. Groups of heaters with a common vent must be controlled by a common thermostat. AWARNING: COMMON VENTING OF MULTIPLE HEATERS IN CONFINED SPACES IS PROHIBITED. If any heater connected to a common vent system for multiple heaters Is found Inoperative, the heater should be disconnected from the vent system and its entra...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - LTS 100 (1.33 mb)
elektrische Heizungen - LTS 110 (1.33 mb)
elektrische Heizungen - LTS 120 (1.33 mb)
elektrische Heizungen - LTS 125 (1.33 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien