Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Napoleon Fireplaces, modell GDS 28-N

Hersteller: Napoleon Fireplaces
Dateigröße: 786.97 kb
Dateiname: 202943bb-903f-4fe3-a785-ddbe6b070db3.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


B-VENT MODEL GS28: Disconnect the on/off switch wire from terminal 3 on the valve and the second switch wire from the terminal block. Replace each connection using the wires from the wall switch/millivolt thermostat. SERIAL NUMBER NO. DE SERIE MODEL CDVS280/GDS28 APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON STEADY STATE EFFICIENCY (LP): 75% FAN OFF / 79% FAN ON EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE 78% VENT. FONCTIONNE EFFICACITE CONSTANTE (GP): 75% VENTILATEUR ARRETE 79% VENTILATEUR FONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY / L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA. AFUE (NG/LP) (GN/GP): 64% / 65% MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT. THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM. L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR. MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP) PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN) 10" D'UNE COLONNE D'EAU (PG) MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP) PRESSION D'ALIMENTATION MIN: 4.5" D'UNE COLONNE D'EAU (GN) 11" D'UNE COLONNE D'EAU (PG) MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP) PRESSION D'ALIMENTATION MAX: 7" D'UNE COLONNE D'EAU (GN) 13" D'UNE COLONNE D'EAU (PG) FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE. WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT. MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES: A 7" D 17." B 2" E 6." C 1" F 9." 20" TO CEILING FROM STOVE TOP 20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ MODEL CS280/GS28 APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO. STEADY STATE EFFICIENCY (NG): 80% FAN OFF / 82% FAN ON STEADY STATE EFFICIENCY (LP): 80% FAN OFF / 83% FAN ON EFFICACITE CONSTANTE (GN): 80% VENT. ARRETE 82% VENT. FONCTIONNE EFFICACITE CONSTANTE (GP): 80% VENTILATEUR ARRETE 83% VENTILATEUR FONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY / L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA. AFUE (NG/LP) (GN/GP): 66% / 68% THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT. NOT FOR USE WITH SOLID FUEL UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL WOLF STEEL LTD BARRIE, ONTARIO CANADA MADE IN CANADA / FABRIQUE AU CANADA WS-385-165 GDS28 CERTIFIED UNDER: CSA 2.33A-M98, ANSI Z21.88A-1998 VENTED GAS FIREPLACE HEATER. APPLIANCE MUST BE INSTALLED USING BURNER KIT: GDS28BN-KT, OR GDS28BP-KT. HOMOLOGUE SELON LES NORMES: CSA 2.33A-M98, ANSI Z21.88A-1998 FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION. CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT UN ENSEMBLE DU BRULEUR: GDS28BN-KT, OU GDS28BP-KT. ALTITUDE / ELEVATION INPUT / ALIMENTATION REDUCED INPUT / ALIMENTATION REDUITE OUTPUT (CDVS280/GDS28) RENDEMENT OUTPUT (CS280/GS28) RENDEMENT ORIFICE / INJECTEUR DIRECT VENT MODEL ‘B’ VENT MODEL 0-4500ft (0-1370m) 30,000 BTU/h 18,000...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - GS 28-N (786.97 kb)
elektrische Heizungen - GS 28-P (786.97 kb)
elektrische Heizungen - GDS 28-P (786.97 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien