Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung AEG, modell WSP 5010

Hersteller: AEG
Dateigröße: 482.51 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Contactors, fuses and similar can be connected for this. • A later increase in the output must be approved separately by the responsible electricity supply company. Failure to notify the electricity supply company of the increase in the output constitutes a breach of the electricity supply contract. • The operating equipment must be designed for the rated consumption of the units. • The unit's rating plate must be observed! The specified voltage must match the rated voltage. • The unit must be fixed to meet the VDE standing safety requirement. For the Fitter 2.4 Installation Site The unit may not - be operated in rooms where there is a risk of fire or explosion due to chemicals, dust, gases or /V fumes; I- be operated in the immediate vicinity of pipes or containers which carry or contain inflammable or explosive substances; - be operated when the minimum distances from adjacent object surfaces are not kept. In rooms in which exhaust fumes, oil and petrol smells occur, the unpleasant smell may linger and could possibly cause soiling. Installation wall Check whether a wall of sufficient stability is available for fastening the unit. If no suitable fastening wall is available, the unit must be fixed to the floor (screwed directly to the floor or to another floor console [special accessory]). Floors The standing surface of the unit must be level and sufficiently stable so that the housing is not deformed. A temperature resistance of the fastening wall of at least 85 °C and of the floor of at least 80 °C must be ensured. The units can be placed on any conventional floor but changes may occur in the rail area on PVC, parquet and long pile carpeted floors under the influence of pressure and temperature. In this case heat-resistant underlay tiles must be used (to be provided on site). 2.5 Unit Installation (fig. 3-14) The storage heater must be secured by a wall or floor fixture (fig. 8) to meet the VDE standing safety requirement. The screws and plugs necessary for fixing the unit are not included in delivery. They must be selected and provided by a qualified fitter depending on the respective wall material. Wall fastening There is a hole in the unit rear wall in the vicinity of the switching area through which a suitable screw can be inserted for fixing to a sufficiently stable wall (fig. 8). Before fixing the unit, make sure that the permissible minimum distances from adjacent objects are kept. Floor fastening The unit is fixed to the floor by screwing the bottom of the unit to the floor through 4 9 mm holes (see "Technical Data”, page 9 for dimensions). This type of fixture is only possible with the air outlet and inlet grilles and the fan drawer removed. 27 For the Fitter 2.5.1 Unit Installation (fig. 3-6) • Press the air inlet grille (6) down slightly on both sides, tip forward at the front and remove. Unscrew both screws at the air outlet grille (5) and remove the grille (fig. 3). • Loosen the front wall (4) with 2 screws at the bottom (inside threaded holes), lift the front wall slightly and remove (fig. 4). Loosen the inside front wall with 2 screws at the bottom and remove (fig. 5). • Disassembly of the right side wall (3): Remove the rotary knob (a), screw (b) on the side wall (3), pull the side wall slightly to the side at the back (c), push forward, tilt to the side at the top (d), lift and remove (fig. 6). • Feed the power cables and connecting cables for charging control unit and discharge control unit through the opening in the unit rear wall (15) and connect according to section 2.5.2 (lay connecting cable about 210 mm and shorten as required so that it does not obstruct the air vents in the side wall); • Place the unit at the planned location and screw to the wall (or to the floor if floor fixing is necessary). • Remove cover plate (10), cardboard inlays and operating button from inside (fig. 9). This must be completely free of foreign bodies such as packing leftovers. /£\ Check the thermal insulation in the unit for transportation damage and replace if necessary. Insert the storage blocks (fig. 10 and 11) The storage blocks are delivered packed separately. Storage blocks with slight transportation damage may still be used. This does not impair the function of the heater. The heating elements (17) must be lifted slightly to insert the storage blocks (9) (fig. 10). Place the first storage block with the heating element recess at the top some distance away from the right thermal insulation under the heater and push to the right and rear thermal insulation. The elongated holes form the heating channels. When lifting the heating elements, make sure that the through holes in the side thermal insulation are not widened by the heating elements. Then push the cover plate (10) removed from the interior over the top...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - WSP 4010 (482.51 kb)
elektrische Heizungen - WSP 2010 (482.51 kb)
elektrische Heizungen - WSP 3010 (482.51 kb)
elektrische Heizungen - WSP 6010 (482.51 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien