Anleitung Blue Rhino, modell Charmglow 82300
Hersteller: Blue Rhino Dateigröße: 1.58 mb Dateiname: eaa183e5-e7dd-b1d4-4d35-f4e28a909f44.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
• Clear an area large enough to layout all components and hardware. • When applicable, tighten all hardware connections by hand first. Once the step is completed go back and fully tighten all hardware. • Follow all steps in order to properly assemble your product. To complete assembly you will need: • (1) Leak Detection Solution (Instructions on how to make solution are included in step Operations Section) • (1) Precision Filled LP Gas Grill Tank with Acme Type 1 external threaded valve connection (4-5 gallon size) Note: You must follow all steps to properly assemble heater. Typical assembly: approximately 20 minutes. 3 Attach Emitter Assembly A x 4 4 Attach Top Wire Guard Installing LP Gas Tank To operate you will need (1) precision-filled standard grill LP gas tank (20 lb.) with external valve threads or (1) 14.1 oz or (1) 16.4 oz LP gas tank. Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A precision-filled standard grill LP gas tank should weigh no more than 38 lbs. Insert and Secure (1) 14.1 oz or (1) 16.4 oz LP Gas Tank Only cylinders marked “propane” may be used. Note: Some 1-lb cylinders may form frost when near empty. Line up threads on canister with those on regulator, insert and rotate canister clockwise until they fit snugly together. HAND TIGHTEN ONLY. Be careful not to cross threads when screwing in canister. Disconnect (1) 14.1 oz or (1) 16.4 oz LP Gas Tank Before disconnecting make sure the heater control valve is “OFF”. Rotate LP gas tank counterclockwise until it is loose. Store the LP gas tank in a proper location. Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one. 5 Attach Dome B x 3 6 Attach Dome Cap and Finial Operating Instructions Inspect the visible portion of the hose before each use of the appliance. Inspect the entire hose assembly at least annually. Checking for Leaks Burner Connections Make sure the regulator valve and hose connections are securely fastened to the burner and the tank. If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice. WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property. Please refer to diagram for proper installation. If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance. Tank/Gas Line Connection Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water. Make sure control knobs are off. Attach (1) 14.1 oz or (1) 16.4 oz LP gas tank. Spoon leak check solution at all “x” and arrow locations. If any bubbles appear disconnect gas tank, reconnect and re-test. If you continue to see bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for assistance. If no bubbles appear after one minute turn tank “OFF”, wipe away solution and proceed. Before Turning Gas Supply ON Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a building, garage, or any other enclosed area. Make sure surrounding areas are free of combustible materials, gasoline, and other flammable vapors or liquids. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks. Be sure the access panel is clear of debris. Be sure any component removed during assembly or servicing is replaced and fastened prior to starting. Before Lighting Heater should be thoroughly inspected before each use, and by a qualified service person at least annually. If relighting a hot heater, always wait at least 5 minutes for gas to dissipate. Lighting 1. Turn control knob to “OFF” position. 2. Turn on gas at LP gas tank. 3. Push in control knob and rotate to “ON” position. This will activate the built-in ignitor and light the burner. If necessary, keep depressing and rotating knob until burner lights. 4. Once burner is lit, hold control knob in for at least 30 seconds and release. 5. If burner does not stay lit, turn to “OFF” position and wait 5 minutes and repeat steps 2 and 3. 6. If ignitor does not light burner, use a lit match positioned against the bottom of emitter screen at burner location, and repeat steps 2 and 3. 7. Once burner is lit, rotate knob to desired heating level. If you experience any ignition problem, turn off the heater and gas supply, and consult “Troubleshooting”. Caution: Avoid inhaling fumes emitted from the heater’s first use. Smoke and odor from the burning of oils used in manufacturing will appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater should NOT produce thick black smoke. Note: The burner may be noisy when initially turned on. To elimin...