Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Generac Power Systems, modell Steambath Generator AK6

Hersteller: Generac Power Systems
Dateigröße: 121.2 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If you become uncomfortable or experience any of the above conditions exit the steambath immediately. Steambaths can put undue stress on the body. Therefore a steambath should be used only under a doctor's direction if you: Are pregnant Have a heart condition Have high blood pressure Have circulatory problems Are under the influence of alcohol Are under the influence of drugs Have diabetes Are under the care of a physician Are in generally poor health Children should only use the steambath under close adult supervision. Scald Hazard: Do Not Touch the steam head or trim during operation as they are HOT. Stay at least 12 inches away from the hot steam escaping from the steam head„ It is recommended that the steambath not be operated for more than one timer cycle without allowing the steam bath enclosure to cool because of the following: Certain construction materials may be damaged by the higher than normal heat, A scald hazard could be presented by bath fixtures overheating, Be careful when entering a steambath. Escaping steam from an overheated steam room may cause injury. 4209-38 9-15-04 AMÍEREG. AK and 3K Series with R30K Control Owners Manual page 2 SECTION 3: TROUBLESHOOTING GUIDE The Troubleshooting Guide beiow is meant as a general aid only. There are no user serviceable parts in the generator All repairs should be performed by a qualified service person For additional assistance or the factory authorized service person nearest you call AMEREC's Service Department at 1 -800-331 -0349 SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKEN Control 'ON' (Control Liolitod) no Steam No water to Generator or Control circuit is faulty or Generator is faulty 1 Wait at feast 10 minutes after turning on Control 2 Verily that the water is on. 3 Verily that the Generator s drain vafve is closed. 4 If the above 4 steps do not disclose the problem turn off the Generator s circuit breaker Call AMERECs Servicc Department Control 'OFP (Control liolil oil) Unit still makes steam Control circuit is laolty or Generator is faulty 1 Turn off circuit breaker 2 Call AMEREC s Service Department Water runs out steam head Generator is faulty 1 Turn of 1 circuit breaker 2 Turn elf water. 3. Call AMEREC’s Service Department. /fAMEHEC ////// SAUNA & STEAM 17683 128th Place NE, Building C Woodlnvflie, Washington 98072, USA 425*951-1120 Fax: 425-951-1130 4209-38 9-15-04...

Dieses Handbuch ist für folgende Modelle:
Stromerzeuger - Steambath Generator AK7 (121.2 kb)
Stromerzeuger - Steambath Generator AK6 (121.2 kb)
Stromerzeuger - Steambath Generator 3K12 (121.2 kb)
Stromerzeuger - Steambath Generator 3K12 (121.2 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien