A safety control check for satisfactory performance must be performed. 1. High limit control - Remove the temperature control cover as needed and note temperature setting. With the burner running reduce the high limit setting until the burner shuts off. Return the high limit to its original setting. 2. To check the primary control and flame sensor shut off oil supply with hand valve while burner is running, fifteen seconds after flameout, the safety switch locks out, ignition stops and the oil valve should close. To restart, open oil supply value and reset safety switch. Maintenance IMPORTANT Escaping gasses are dangerous. A qualified serviceman should inspect the entire flue and venting system at least once a year. Do not use the boiler if any part has been under water. Call a qualified service technician to inspect the boiler and replace any part of the control system, which has been under water. Never operate this appliance with any safety switches altered or disabled. Never attempt to modify this appliance in any fashion. Oil Filter The oil filter cartridge should be replaced annually. Boiler At the beginning of each heating season, the boiler flue passages and the oil burner should be checked for cleanliness and if necessary they should be cleaned. The following procedure is required for inspection and cleaning the boiler flue passages. 1. Turn off all electrical power to the boiler before inspecting and cleaning. 2. Disconnect the Molex plug at burner. 3. Remove the boiler front jacket panel by lifting vertically. 4. Open the swing door following previously described procedure. 5. If required remove scale and any soot deposits with a flexible flue brush. Vacuum all deposits from flue passages and chamber area. Be careful not to damage the door insulation. 6. Close swing door following previously described procedure. Check to ensure a proper seal between the door and the boiler has been made. 7. Eliminate any combustion gas leaks by replacing worn seals and gaskets. 8. Install jacket front panel. 9. Connect Molex plug for burner power. 10. Avoid emptying the heating system. Introduction of fresh water will only add contaminates which will increase the possibility of rust and scale. 11. Protect the heating system against freezing dangers with anti-freezes as required. Avoid intercommunications between domestic hot water and heating water since these antifreezes are toxic substances. 12. Check the piping system for leaks and repair as required. This will prevent water turnover with consequent risk of scale formation and corrosion in the boiler room. 13. Lift the lever of the pressure relief valve on the boiler to make sure that it is functioning properly. The pressure relief valve should be open before the water pressure exceeds the 30PSI. If the relief valve is leaking, replace immediately. Corrosion can build up rapidly at the valve seat and prevent its functioning as a safety device. Oil Burner 1. Thoroughly clean the burner fan blades. Only with clean fan blades is proper combustion air delivery possible. 2. Clean nozzle assembly and all air handling parts. 3. Check spacing and condition of ignition electrodes. Clean and replace as required. 4. Nozzles should be inspected every year for plugged orifices. If it is necessary to replace the nozzle, use only the specified nozzle to be sure that the replacement meets spray specifications for the boiler burner combination. 5. Consult oil burner manufacturer’s instructions for additional maintenance requirements. Vent System Chimney Vent- Inspect the chimney to ensure its cleanliness, the proper size, in good condition. Remove any accumulation that may have occurred at the clean out door. Inspect and clean all vent piping, replacing as necessary. Direct Vent – Inspect and clean vent and air intake piping. Replace and reseal joints as required. Inspect vent hood air inlet and discharge for obstruction. Domestic Hot Water Storage Tank 1. Sizing of the hot water tank must be matched with the hot water usage. 2. Piping must be in accordance with the appropriate codes and the Solaia manual. 3. Follow the installation instructions of the hot water domestic tank you have chosen to install with the Solaia boiler. Danger… Water temperature exceeding 125 F will cause severe burns instantly or death by scalding. • An automatic mixing valve must be installed on the outlet of the domestic waterside of the tank. Installation must comply with the valve manufacture’s recommendations, and instructions. • Pipe in accordance with the installation manual. • Due to varying water conditions, an adjustable flow restrictor may be required in the coldwater inlet of the tank. Trouble Shooting Guide Burner Will Not Start Thermostat SetAbove RoomTemperatureHigh Limit Set onAquastat to 180Deg.Min. 110 Volts betweenL1 andL2 atAquastat110 Volts betweenB1 andB2 atAquastat110 Volts atBurnerRefer to OilBurner ManualAdjustThermostatAdjust HighLimitCheck Fuses andSafety SwitchesAquastatin Fau...
Dieses Handbuch ist für folgende Modelle:Elektrische Backöfen - SL7175 (528.43 kb)
Elektrische Backöfen - SLD375 (528.43 kb)
Elektrische Backöfen - SLD4100 (528.43 kb)
Elektrische Backöfen - SLD5125 (528.43 kb)