No part of this manual may be reproduced or transmitted in any form without written permission from AC T
Capacitors retain charge after power is removed. Disconnect power and wait at least three minutes before servicing the drive. STOP! • Verify mains voltage before connecting to drive. • Do not connect mains power to the output terminals (U,V,W)! Severe damage to the drive will result. • Do not cycle mains power more than once every two minutes. Damage to the drive will result. 3.2.1.1 Mains connection to 120VAC Single-Phase Supply ESV…N0 S… PE L1 L2 N PE L1 N 3.2.1.2 Mains connection to 240VAC Si
Our products are also UL Recognized. 4241 12th Ave E #400, Shakopee, MN 55379 • 1-877-297-6937 • Technical Specifications General Model # CPS1220RMS Input Voltage 110/120 Nominal Frequency 60Hz Current Draw 20A Load Capacity 2400 VA Plug Type NEMA 5-20P Cord Length 15'; 12 Gauge Output Outlets - Total 12 Outlets - Front 2 x NEMA 5-20R Outlets - Rear 10 x NEMA 5-20R Surge Protection and Filtering Surge Suppression 1800 Joules EMI/RFI Filtration EMI/RFI Indicator
The 1220RM offers 12 (twelve) 20A outlets (6 front, 6 rear-mount) the 19” 1U case. The rugged metal housing can withstand the most demanding environments, and a 15’ cord ensures compatibility for most rackmount applications. CyberPower PDU’s can also be used for retail, security, POS, telecommunications, networking, audio/video displays, or anywhere dedicated power distribution is needed. • EMI/RFI Shielding - Provides shielding against electromagnetic interference & radio frequency signals. Mo
Providing additional outlets for your rackmount power needs, this model also offers 1800 Joules of surge/lightning protection. The 1215RMS offers 12 (twelve) 15A outlets (6 front, 6 rear-mount) in the 19” 1U case. The rugged metal housing can withstand the most demanding environments and a 15’ cord ensures compatibility for most rackmount applications. CyberPower PDU’s can also be used for retail, security, POS, telecommunications, networking, audio/video displays, or anywhere dedicated power di
The 1215RM offers 10 (ten) 15A rear-mounted outlets in the 19” 1U case. The rugged metal housing can withstand the most demanding environments and a 15’ cord ensures compatibility for most rackmount applications. CyberPower PDU’s can also be used for retail, security, POS, telecommunications, networking, audio/video displays, or anywhere dedicated power distribution is needed. • EMI/RFI Shielding - Provides shielding against electromagnetic interference & radio frequency signals. Most commonly,
40 BIOS Setup Utility SY- P4I865PE Plus DRAGON 2 Chapter 3 BIOS SETUP UTILITY This Motherboard's BIOS setup program uses the ROM PCI BIOS program from Award Software Inc. To enter the Award BIOS program's Main Menu: 1. Turn on or reboot the system. 2. After the diagnostic checks, press the [Del] key to enter the Award BIOS Setup Utility. Phoenix – Award BIOS CMOS Setup Utility ..PC Health Status Load Fail - Safe Defaults Load Optimized Defaults Set Supervisor Password Set User Password Save & Ex
Note: Only section headings and keywords supported by the cooling unit from which you retrieve the file are included. • Each keyword is followed by an equals sign and the current value for that parameter’s setting, either the default value (if the value has not been specifically configured) or the configured value. –The Override keyword, with its default value, prevents one or more keywords and their device-specific values from being exported. For example, in the [NetworkTCP/IP] section, the def
SMTP Server Selects one of the following methods for routing e-mail: • Local: Through the SMTP server of the cooling unit (the recommended setting). This option ensures that the e-mail is sent before the cooling unit’s 20-second time-out, and, if necessary, is retried several times. Also do one of the following: • Enable forwarding at the cooling unit’s SMTP server so that it can route e-mail to external SMTP servers. Typically, SMTP servers are not configured to forward e- mail. Always check wi