Anleitung American Power Conversion, modell 1500 VA
Hersteller: American Power Conversion Dateigröße: 1.66 mb Dateiname: ASTE-6Z8LC8_R0_EN.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
-UPS 1500/3000 VA 1500/3000 VA1500/3000 VA1500/3000 VA1500/3000 VA 120/230 Vac 120/230 Vac120/230 Vac120/230 Vac120/230 Vac Mod ModModModModu uuuular larlarlarlar Uninterruptible Power Supply Uninterruptible Power SupplyUninterruptible Power SupplyUninterruptible Power SupplyUninterruptible Power Supply 990-1704 01/2004 Introduction This APC Smart-UPS is a modular Uninterruptible Power Supply (UPS) for high availability applications such as data centers and mission critical processes, designed to prevent blackouts, brownouts, sags, and surges from reaching your equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS provides continuous power from its internal battery until the utility line returns to safe levels or the battery is fully discharged. 1: INSTALLATION The User Manual and Safety Guide are accessible on the supplied User Manuals CD and on the APC web site, Unpack Attention: Read the safety instruction sheet before installation. Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents: UPS Bezel Tower conversion top panels and mounting stabilizers Rail kit UPS literature kit containing: . Product documentation, safety, Serial and USB communication and warranty information cables Smart-UPS User Manuals CD 230 V models only: PowerChute® CD Two input power cords Network Management Card CD Four output jumper cords . Mounting hardware Position the UPS in the Specified Environment 0-40°C 0-95% 1 Mount the UPS in the Rack and Connect the Battery Attention: Install the rails following the instructions in the rail kit. . Rear 2 Tower Configuration . Press and hold the black switch (see location . designation on UPS) to the right while removing the power processing module. . Note: Place the UPS in the final operating location prior to module reinstallation. . Snap the display bezel out the rear to begin . rotation. Rear 3 2: START UP Connect Equipment to the UPS Rear Panels 1500 VA, 120 V: 1500 VA, 230 V: 3000 VA, 120 V: 3000 VA, 230 V: Note: • The .outlet groups. can be controlled through the network software. See Network Management Card documentation. • A laser printer draws significantly more power than other types of equipment and may overload the UPS. Connect the UPS to the Network (if Applicable) Network Connectors Serial Port USB Port Ethernet Port Note: • Use only the supplied cable to connect to the Serial Port. A standard serial interface cable is incompatible with the UPS. Serial and USB ports cannot be used simultaneously. • If an optional Smart-Slot accessory is to be used, remove the preinstalled network management card and install it now. Start the UPS Attention: Upon utility power connection, the UPS will automatically turn on. 1. Plug the UPS into a two-pole, three-wire, grounded receptacle only. Input Plugs: 1500 VA models: 120 V = NEMA 5-15P; 230 V = Use country specific 10 A with C14 input cords (not supplied). 3000 VA models: 120 V = NEMA L5-30P; 230 V = Use the supplied cords or the country specific equivalent. 4 The battery will charge to full capacity during the first few hours of normal operation. Do not expect full .on battery. capability during this initial charge period. 2. After the UPS has ended the immediate self-test with online LED illumination, check the front display for any fault indicators (see Troubleshooting). 3. 120 V models: Check the site wiring fault LED located on the rear panel. It will be illuminated if the UPS is plugged into an improperly wired utility power outlet (see Troubleshooting). 4. Turn on all connected equipment. To use the UPS as a master on/off switch, be sure all connected equipment is on. Equipment is now powered and protected. Basic operation, user configuration, and software utilization can now be performed as required. Battery Operation The UPS switches to battery operation automatically if the utility power fails. While running on battery, an alarm beeps four times every 30 seconds. Press the button to silence this alarm. If the utility power does not return, the UPS continues to supply power to the connected equipment until the battery is fully discharged. Refer to for battery runtime charts. When the UPS reaches the low battery shutdown warning (two minute default), the alarm will beep continuously until total shutdown. Connected equipment should be shut down during this time, unless being controlled by network monitoring software. 5 3: BASIC OPERATION Front Display Panel INDICATOR DESCRIPTION Online The UPS is supplying utility power to the connected equipment. AVR The UPS is compensating for either a high or low utility voltage. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more than the UPS power ratin...