Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Enerco, modell UNVENTED NATURAL GAS FIRED ROOM HEATER TSBF10NG

Hersteller: Enerco
Dateigröße: 6.32 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


8. Reconnected fittings must be checked for leaks in next section. Test Pressure Equal To or Less Than . psig (3.5 kPa) 1. Close equipment shutoff valve (see figure 13). 2. Pressurize supply piping system by either using compressed air or opening main gas valve on or near gas meter. 3. Check all joints from the gas meter to equipment shutoff valve (see figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. 5. Depressurize and relieve pressure from supply piping system. Pressure Regulator 3/8” NPT Pipe Nipple Heater Cabinet Ground Joint Union Test Gauge Connection Equipment Shutoff Valve Tee Joint Reducer Bushing to 1/8” NPT From Gas Meter (4” W.C. to 10.5” W.C. Pressure) 1/8” NPT Plug Tap Tee Joint Sediment Trap Pipe Nipple Cap 3” Minimum Pressure Testing Heater Gas Connections: 1. Make sure that the heater supply piping system is connected and has been leak tested as described above. 2. Make sure control knob of heater is in OFF position. 3. Open equipment shutoff valve (see figure 13). 4. Open main gas valve on or near gas meter. 5. Check all joints from equipment shutoff valve to control valve (see figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 6. Correct all leaks at once. 7. Light heater (see Operating Your Heater, pages 11 and 12 for thermostat models or pages 9 and 10 for non-thermostat models). Check the rest of the internal joints for leaks. 8. Turn off heater (see To Turn OFF Gas to Appliance, page 12 for thermostat models and page 11 for non-thermostat models). 9. Replace lower front panel. Figure 13 Figure 14 ELECTRICAL WIRING DIAGRAM: Figure 15 If any original wiring as supplied with the heater must be replaced, it must be replaced with type AWG 105oC wire or its equivalent except as indicated. WARNING: Electrical Grounding Instructions: This heater is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three- prong receptacle. OPERATING YOUR HEATER NON-THERMOSTAT MODELS IR10NG / BF6NG / BF10NG FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you can not reach your gas supplier, call the fire department. Open Equipment Shutoff Valve Closed Control Valve Gas Meter Equipment Shutoff Valve C. Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been underwater. LIGHTING INSTRUCTIONS 1. STOP! Read the all safety information included with and on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob and slightly turn clockwise to the OFF position (see figure 16). Note: Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. Do not force. 4. Wait five (5) minutes. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step. 5. Push in gas control knob slightly and turn counterclockwise to PILOT/IGN and depress for five (5) seconds. Note: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about 30 seconds. This will allow air to bleed from the gas system. 6. Push in control knob and rotate control knob back to OFF position then rotate counterclockwise to PILOT/IGN position. This will light pilot. If needed gently keep rotating control knob back and forth while depressed until pilot lights. 7. Keep control knob depressed in for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 4, 5, 6 and 7. • If pilot does not stay lit, refer to Troubleshooting, pages 14 & 15. Also, contact a qualified service person or gas supplier for repairs. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 8. FOR IR10NG: When the pilot is lit, turn the control knob to “LO” position to light hea...

Dieses Handbuch ist für folgende Modelle:
Gas Heizthermen - UNVENTED NATURAL GAS FIRED ROOM HEATER HSBF10NG (6.32 mb)
Gas Heizthermen - UNVENTED NATURAL GAS FIRED ROOM HEATER HSIR10NG (6.32 mb)
Gas Heizthermen - UNVENTED NATURAL GAS FIRED ROOM HEATER HSIR20NGT (6.32 mb)
Gas Heizthermen - UNVENTED NATURAL GAS FIRED ROOM HEATER MHBF10NG (6.32 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien