Electrical Work
WARNING


English
Electrical work must be
Electrical connections
performed by a legally
qualified electrician.
1. Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance


branch circuit.
Electrical requirements
2. Connect the power cord.
- This appliance must be supplied with the proper voltage and frequency, and
Connect the power cord in accordance with all governing codes and
connected to an individual, properly earthed branch circuit, protected by a
ordinances.
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
- This appliance is not fitted with other means for disconnection from
- Single-phase connection (220-240 V ~ 50 Hz)
the supply mains having a contact separation in all poles that provide
Connect the wires in accordance with the instructions given in the
full disconnection under overvoltage category III conditions. Means for
following table and diagram:
disconnection must be incorporated in the fixed wiring in accordance with
the wiring rules.
Electirical cable
Wire connection
- You must use a two-wire, single-phase A.C. 220-240 V, 40 A, 50 Hz
electrical system. (It is also possible to use a four-wire, three-phase.)
E: Yellow / Green
If you connect to aluminum wiring, properly use connectors approved for
E
(Connect to the earth terminal)
use with aluminum wiring.
N
N: Grey and Blue together
- Check with the local utilities for electrical codes applied in the area.
L: Black and Brown together
Failure to wire the appliance according to governing codes may result in a
L
(Connect to the live terminal)
hazardous condition.
- After installation, show the customer where the breaker for the appliance is
located.
- Three-phase connection (380-415 V 2N~ 50 Hz)
Separate the L wires and connect them in accordance with the
instructions given in the following table and diagram:
Electirical cable
Wire connection
E: Yellow / Green
E
(Connect to the earth terminal)
N
N: Grey and Blue together
L1
L1: Black

■ Installation of the earth leakage circuit breaker
L2: Brown
L2
(Connect to the live terminal)
- In accordance with the electrical wiring rules, incorporate the earth leakage
circuit breaker in the home electrical wire.
- Follow the specification of the earth leakage circuit breaker as follows.
Rated current: 40 A, rated sensitivity current: 30 mA
12