Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Follett, modell U155XR800A/W

Hersteller: Follett
Dateigröße: 558.48 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Check that ice is in the dispenser and that congealed cubes are not causing a jam. 2. Check that circuit breaker and switches are in ON position. 3. Check that drain pan, rear lid and top are on securely. If ajar, dispenser will not operate. When the top is off, auger does not operate, even though the solenoids do (page 16). 4. Check that all drains are clear. Note: For units equipped with Follett compressed nugget icemaker, see Icemaker Operation and Service Manual for service and troubleshooting information. Symptom Ice does not dispense. • Auger motor does not run • Wheel motor does not run Ice does not dispense. • Auger motor runs • Wheel motor runs • Gate does not open Ice does not dispense. • Auger motor does not run • Wheel motor runs Ice does not dispense. • Auger motor runs • Wheel motor does not run Warm drinks or soda foaming. No ice in dispenser. Possible cause Solution 1. Power switch faulty or in OFF position; loose connection. 2. Faulty dispense switch. 3. Faulty transformer. 4. Drain pan ajar. 5. Faulty drain pan safety switch. 1. Turn power switch to ON position; check connections. 2. Replace switch. 3. Replace transformer. 4. Check pan and reseat. 5. Replace switch. 1. Loose electrical connection. 2. Linkage problem between solenoid and gate. 3. Faulty solenoid. 1. Check connections. 2. Check linkage. 3. Replace solenoid. 1. Loose electrical connection. 2. Faulty auger motor. 3. Faulty run capacitor. 1. Check connections. 2. Check auger motor. 3. Check run capacitor. 1. Loose electrical connection. 2. Faulty wheel motor. 3. Faulty run capacitor. 1. Check connections. 2. Check wheel motor. 3. Check capacitor. 1. No ice in storage bin. 2. Water drained out of ice water bath. 3. Circulating pump not running. 1. Fill storage area with ice or check icemaker operation. 2. Check that ice water bath drain tube is in fixed upright position. 3. Check pump and PC board for output. 1. Power switch in OFF position or faulty. 2. Bin signal switches in OFF position or faulty. 3. Faulty bin thermostat. 4. Faulty transformer. 5. Icemaker related problem. 6. Faulty or disconnected wiring. 1. Check switch and replace if necessary. 2. Check switch and replace if necessary. 3. Replace bin thermostat. 4. Replace transformer. 5. Refer to icemaker Operation and Service Manual for diagnosing. 6. Check for power and bin signal on icemaker PC board. If problems persist after following this basic troubleshooting guide, call Follett’s technical service department toll at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301. 15 Operational Status The chart below shows the operational status of various parts when certain switches are turned off or accessories are removed. Condition Pump Solenoids Auger Wheel Beverage valves Top lid off Rear lid off Drain pan off On/off switch in off position Beverage switch in OFF position OFF ON ON OFF ON ON ON ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF ON ON ON OFF OFF OFF Waterbath circuit board operation The temperature sensor is hard wired directly to the circuit board. The waterbath circuit board operates on 24 volts AC. The...

Dieses Handbuch ist für folgende Modelle:
Dispenser - U155BR400A/W (558.48 kb)
Dispenser - U155B (558.48 kb)
Dispenser - U155BR800A/W (558.48 kb)
Dispenser - U155BX (558.48 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien