Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Pentair, modell MiniMax NT Standard Series

Hersteller: Pentair
Dateigröße: 1.81 mb
Dateiname: 7f5f9daa-fc69-3874-d9c3-4aa5e69a5a4e.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


4. Corrosion of copper in the heater, which may cause leaks. 5. If you have a sand and gravel filter, the alum used as a filter aid may dissolve and pass through the filter. CAUTION: Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is 6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry. RULE: Chemicals that are acid lower pH. Chemicals that are alkaline raise pH. Table 4. pH Control Chart 6.8 7.0 7.2 7.4 7.6 7.8 8.0 8.2 8.4 Add Soda, Ash or Sodium Bicarbonate Marginal Ideal Marginal Add Acid ALKALINITY High - Low: "Total alkalinity" is a measurement of the total amount of alkaline chemicals in the water, and control pH to a great degree. (It is not the same as pH which refers merely to the relative alkalinity/acidity balance.) Your pool water's total alkalinity should be 100 - 140 ppm to permit easier pH control. A total alkalinity test is simple to perform with a reliable test kit. You will need to test about once a week and make proper adjustments until alkalinity is in the proper range. Then, test only once every month or so to be sure it is being maintained. See your local pool dealer for help in properly balancing the water chemistry. Rev. A 1-2-02 P/N 472032 26 Troubleshooting—Normal Operation Sequence of Heater NORMAL OPERATION SEQUENCE (Refer to Figure 20 of Pentair Temperature Controller 7800 keyboard) The heater features a fully automated firing start-up and shutdown sequence under the control of the MiniMax NT Standard Pentair Temperature Controller 7800. Now that the heater has been properly installed and wired for either remote operation or local operation, and you have setup the Pentair Temperature Controller 7800 temperature setpoints as described earlier in manual in Thermostat section, the following is the normal operating sequence when the heater turns on the and the thermostat calls for heat for the pool or spa. 1. The fan will start beginning the heater’s safety prepurging cycle which lasts for 1 minute. If at anytime during the prepurge cycle the Pentair Temperature Controller 7800 detects that a safety control is not working due to either a safety control malfunction or other unsafe condition the firing sequence will stop until the unsafe condition is removed— “the fault icon related to the problem will illuminate”. 2. After proper completion of the prepurge cycle, the hot surface ignitor (glow coil) will turn on (preheat) for 40 seconds. Once the 40 seconds is passed, the main gas valve will open and the heater will fire. At this time, if flame is not safely established as detected by the flame sensing circuit, the ignition module and Pentair Temperature Controller 7800 will shut down and will display an ignition fault and luminate the red service light. Please note that on initial firing of heater when gas supply piping is full of air or after long period of non-operation of the heater it is normal for the first ignition attempt to not complete. To clear the fault condition power to the Pentair Temperature Controller 7800 must be cycled to reset system. If heater continues to fail to light have heater inspected by a qualified service person before placing heater back in service. Insufficient waterflow (pump icon displays), excessive water temperature (high limit icon) cause a “soft-lockout” of the firing sequence—which means if the cause of the problem clears by itself (or with human intervention ie., turning on pump, etc.) such as a slow to prime water pump finally pumping adequate waterflow causing the water pressure (safety) switch to close, the ignition sequence automatically restarts again. The other category of fault conditions lead to a “hard lockout” of the firing sequence which require a qualified service person to correct before the heater is returned to service. In “hard lockout” the heater must be manually reset (by toggling power to Pentair Temperature Controller 7800) after correction of the fault condition. 3. After normal firing of the heater (main burners) the heater will continue to operate until the temperature setpoint is reached (thermostat satisfied). As the pool/spa loses heat the heater will refire and continue to operate cycling automatically to maintain the selected temperature setpoint for either the pool or spa. If at anytime during the firing of the heater an unsafe condition is detected the heater will stop firing and an automatic safe shutdown sequence will begin. Investigate and have corrected the cause of the abnormal firing termination before placing heater back in operation. Please Note: During the firing of the heater, you decide to change to the pool or spa selection by depressing the selector key for “POOL” or “SPA”, the heater will first acknowledge the new selection by flashing the new selection’s corresponding selection LED “POOL” or “SPA”, however, the heater will first complete a safe shutdown sequence before automatically switching to the new selected...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien