The heater may be hard wired with either 120 or 240 VAC to convert to 240 VAC, change the transformer wiring connected to the output side of the terminal block first. The heater must be grounded and the heater electrically bonded. All wiring must comply with all local codes, or in the absence of local codes with the NEC ANSI/NFPA 70. Electrical Rating 60 Hz 115 V.A.C. or 230 V.A.C. 50/60 Hz 208 V.A.C. or 240 V.A.C. NOTE If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 awg 105° C. U.L. approved AWM low energy stranded) copper wire or it's equivalent. In Canada: wires must be CSA approved. CAUTION The heater must be electrically grounded and bonded in accordance with local codes or, in the absence of local codes, with the latest national electrical codes ANSI/NFPA No. 70. In Canada: CSA standard C22.1 Canada Electrical Code Part 1 and/or local codes. TRANSFORMER WIRING INSTRUCTION P/N 471105 Rev. F 1-22-04 19 Rev. F 1-22-04 P/N 471105 Installation (contd.) MiniMax 100 Electronic Direct Spark Ignition Wiring Diagram THERMAL FUSE HI LIMIT SW. PRESSURE SW. WATER THERMOSTAT ON/OFF SW. IGNITER SPARK MODULE GAS VALVE MiniMax 100 ELECTRONIC WIRING DIAGRAM CODE OR SUPERCEDING LOCAL (WIRING) CODES. INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL WIRE, 18 GAUGE, 600V, 150° C TEMPERATURE RATING.. THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 150° C TEMPERATURE RATING. IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE GROUND SCREW WITH PAINT CUTTING WASHER EXTERNAL BOND LUG CHASSIS SHEET METAL V2/GRD V1 TH H N GRN WHT BLUE WHT ORN ORN GRN WHT WHT WHT WHT WHT WHT ELECTRONIC 1 2 3 4 TRANSFORMER WIRING : 115V CONN LINE : 1 & 2 (TIED) LINE : 3 & 4 (TIED) 230V CONN 2 & 3 (TIED) LINE : 1 LINE : 4 WHT/RED WHT/BLK BLK RED MiniMax 100 Millivolt Wiring Diagram Remote Wiring Hook-up The MiniMax 100 may be connected to a two wire remote control by disconnecting the wire connector from the hot (transformer) side terminal of the "ON/OFF" switch and connecting the two wire remote across the end of this wire and the aforementioned terminal. NOTE When connecting a remote control to the MiniMax 100 you must install the low voltage remote control wires in a separate conduit from ANY line voltage wires. Do not exceed 25 ft. wire run for remotes on millivolt models. TROUBLESHOOTING - GENERAL TROUBLESHOOTING -GENERAL Possible Cause Remedy Heater will not come on Automatic ignition system fails Check if electrical connections are correct and securely fastened – If YES, call serviceman. Pump not running Place pump in operation Pump air locked Check for leaks Filter dirty Clean filter Pump strainer clogged Clean strainer Defective wiring or connection Repair or replace wires Defective pressure switch Replace Switch Defective gas controls Call serviceman On-Off switch in "OFF" position Turn switch to "ON" Heater Short Cycling (Rapid On and Off Operation) Insufficient water flow Clean filter and pump strainer Defective wiring Repair or replace wiring Defective or stuck by-pass valve Call serviceman Defective hi-limit and/or thermostat Call serviceman Heater Makes Knocking Noises, Make sure all valves on systems are open Heater operating after pump has shut off Shut off gas supply and call serviceman Heater exchanger scaled Shut off gas supply and call serviceman P/N 471105 Rev. F 1-22-04 PARTS LIST PARTS LIST 21 ITEM DESCRIPTION QTY. P/N 1* 1A 2* 3* 4 5 Indoor Draft Hood Kit consisting of: Indoor Draft Hood (471198) and items 2 & 3Outdoor Top Indoor Top (Cover) Indoor Stack Adaptor Middle Top Flue Collector 1 1 1 1 1 1 471187 471213471075471214471069471059 6 Return Header 1 471096 7 8 Bolt 3/8 x 16 UNC x 3/4 Rubber Seal tube 4 10 471200470742 9 10 11 Heat Exchanger Less Heads Main Header (Inlet/Outlet) Combustion Chamber 1 1 1 471093 471094N.A. 12 13 Ignitor Electrode Bracket Burner Natural Gas 1 1 471058 471122 13a 14 15 Burner Propane Burner (75) Natural Gas Burner Tray Assy. (complete) Natural Gas Millivolt Burner Tray Assy. (complete) Propane Millivolt Burner Tray Assy. (complete) Natural Gas DSI Burner Tray Assy. (complete) Propane DSI Burner Tray Assy. (75) - (complete) Natural Gas Ignitor Electrode Gas Valve-Nat. Gas DSI-Robertshaw 1 1 1 1 1 1 1 1 1 471136 471851 471219 471236 471076 471077 471850 471090 471088 Gas Valve-Propane DSI-Robertshaw Gas Valve-Nat. Gas Millivolt-Robertshaw 1 1 471089 471192 Gas Valve-Propane Millivolt-Robertshaw Gas Valve-Nat. Gas Millivolt-SIT 1 1 072125 471436 16 Gas Valve-Propane Millivolt-SIT Thermostat-Millivolt Models 1 1 471435 072022 17 18 19 20 21 Thermostat (Electronic)-Direct Spark Models On/Off Switch spst Heat Shield Burner Tray Control Panel Assy Door Assembly Control Bracket 1 1 1 1 1 1 471431 471128 471070 471078 471067 471159 22 23 Ignition Control DSI Transformer 1 1 4710...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien