Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung AMX, modell NXD-CV7

Hersteller: AMX
Dateigröße: 3.96 mb
Dateiname: b136cce8-8d1f-4f3e-9ce6-43f89327eac1.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


.. From the Online Tree tab of the Workspace window, select the NetLinx Master. .. Follow steps outlined in either the Obtaining or Assigning the Master’s IP Address sections from your particular NetLinx Master instruction manual to use an address. .. Note the IP Address and Gateway information. 2. Launch NetLinx Studio 2.3 (default location is Start > Programs > AMX Control Disc > NetLinx Studio > NetLinx Studio 2.3). 3. Select Settings > Master Communication Settings, from the Main menu to open the Master Communication Settings dialog (FIG. 73). 4. Click the Communications Settings button to open the Communications Settings dialog. 5. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you are working with a NetLinx Master (such as the NXC-ME260/64 or NI-Series of Integrated Controllers). 6. Click on the Authentication Required radio box (if the Master is secured) and then enter a username and password. 7. Click on the TCP/IP radio button (from the Transport Connection Option section) to indicate you are connecting to the Master through an IP Address. 8. Click the Edit Settings button (on the Communications Settings dialog) to open the TCP/IP Settings dialog (FIG. 73). 7" Modero Widescreen Touch Panels Upgrading Modero Firmware List of previously saved IP Addresses FIG. 73 Assigning Communication Settings and TCP/IP Settings 9. From within the TCP/IP dialog click New to enter the IP information for a new IP Address or select from the list of previously entered IP Address and alter their properties by clicking the Edit button and making your changes. 10. Enter the IP Address into the TCP/IP Address field. This information is obtained from either your System Administrator or obtained from the Master. 11. Click OK when you are done adding or editing the IP Address from the New/Edit TCP/IP Setting dialog. 12. Click OK three more times to close the open dialogs and save your settings. 13. Click Yes to interrupt the current communication from the Master and apply the new settings. 14. Select Tools > Reboot the Master Controller to access the Reboot the Master dialog, then click Reboot to reboot the Master and incorporate any changes. 15. Once the dialog replies with "Reboot of system complete", press Done. 16. Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one. 17. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list. Step 2: Prepare the panel for communication via an IP 1. Press the blue Type field (from the Master Connection section) until the choice cycles to the word Ethernet. 2. Press the blue Mode field until the choice cycles to the word URL. .. By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value directly from the communicating target Master (virtual or not). A Virtual Master system value can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit. 3. Press the red Master IP/URL field to open a Keyboard and enter the NetLinx Master’s IP Address (obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio application). 7" Modero Widescreen Touch Panels Upgrading Modero Firmware 4. Click Done to accept the new value and return to the System Configuration page. 5. Do not alter the Master Port Number value (this is the default value used by NetLinx). 6. Press the Back button to return to the Protected Setup page and press the on-screen Reboot button to restart the panel and save any changes. Step 3: Verify and Upgrade the panel firmware via an IP 1. Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one. 2. Right-click the associated System number (from the Workspace window) and select Refresh System to detect of all devices on the current system, establish a new connection to the Master, and refresh the System list with devices on that system. 3. After the Communication Verification dialog window verifies active communication between the PC and the Master, verify the panel appears in the OnLine Tree tab of the Workspace window (FIG. 74). The default Modero panel value is 10001. FIG. 74 NetLinx Workspace window (showing connected Modero panel) Showing the NetLinx Master firmware version and device number Showing the current Modero panel firmware version and device number Shows NetLinx Studio version number The panel firmware is shown on the right of the listed panel. New G4 firmware features are available with firmware beginning with v2.XX. 4. If the panel firmware version is not the latest available; locate the latest firmware file from the > Tech Center > Downloadable Files > Firmware Files > Modero Panels section of the website. 5. Download the appropriate KIT file to your computer. 6. Verify you have downloaded the latest Modero firmware (KIT) file to a known location. 7. S...

Dieses Handbuch ist für folgende Modelle:
Car Video - NXT-CV7 (3.96 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien