NOTES: Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should be changed every 3 years. Batteries do not perform well in extremely cold temperatures. To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part 27-NP712 for replacement batteries. 18 R93 L1 D42 K2 D1 D1O Z22 P1 F2 MOV1 D1 Q12 U4 OFF MAX OPEN SINGLE BUTTON RESET STOP CHGR OVLD COM COM D129 Z4 U3U3 D2 D44 C11 C13 C12 D16 F9 R1OO R1O1 K1 Q22 F3 K4 K3 R196 F1 Z12 GATE 2 GATE 1 MAGR SOL GR WH YL BL RD BR GR WH YL BL RD BR F7 24V CTRL OVLD TIMER RUNNING GATE 2 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS GATE 1 LEARN XMITTER LOCK / ON OFF C69 OFF MAX J2O PWR AC PWR /SOLAR D8 D4 R9 R329 R27 MOV2 R4 C2 BIPART DELAY LOCK GND Z1 R1 R2 K5 F12 Q9 R9O F8 Q6 Q1 J19 C1O1 R182 C75 C73 C72 C71 C7O C66 C65 C68 C33 F11 R186 R42O R423 J24 J23 3OA 32V 3OA 32V J21 30 30 C64 U2 R22 J18 K6 JU1 JU1 JU2 DB1 D36 R184 Control Board Battery Connection Board Connectors Battery Connectors Solar Panel Installation 32 PROGRAMMING Program Limits The limits are internal settings that indicate when the gates are in the fully open position and the fully closed position. For proper functionality, the limits must be programmed during the installation process. The programming uses a combination of buttons on the control board. The specifi c buttons used for programming depends on which side of the gate the control box is mounted and how many operators the installation includes. Refer to pages 11 and 13 to determine if the gate is Left- or Right-handed. If a mistake is made during programming press the RESET button on the outside of the control box to start over. SINGLE ARM LEFT-HAND SIDE SINGLE ARM RIGHT-HAND SIDE NOTE: The programming can be exited at any time by pressing the RESET button. The programming times-out automatically after 60 seconds of inactivity. 33 Programming Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 K6 K2 F3 10A 32V D1O OPEN EDGE/ PHOTO OPEN PHOTO CLOSE PHOTO R227 R2O7 Z2O R223 P1 Z9 Z8 F2 F6 D4 D2 R9 C64 JMPR1 R224 U4 CONTROL INPUTS FORCE TIMER TO CLOSE OFF MAX OPEN SINGLE BUTTON RESET STOP SHADOW INTERRUPT CHGR OVLD COM COM COM FUSE OPEN LOOP INPUTS POWER BATT 2 BATT 1 F1 20A 32V R35 D9 Z3 Z4 U3 D1 F5 C11 C13 C12 D15 R4 C2 R1O1 R1OO R9O K1 Q9 R196 Q22 D8 K3 K4 D21 D22 C4 ACCESSORY OVLD D6 JMPR2 MOV1 MOV2 DB1 U2 Z12 24 VAC/ SOLAR INPUT GATE 2 ACCESSORY POWER MAGLOCK ALARM GATE 1 C C NC NO NO GRN WHT YEL BLU RED BRN GRN WHT YEL BLU RED BRN F4 10A 32V F7 24V COM OVLD TIMER RUNNING GATE 2 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS DIAGNOSTIC GATE 1 J4 LEARN XMITTER MAGLOCK ON OFF D4 D2 U4 SET OPEN LIMIT RESET BUTTON RESET BUTTON LEARN LIMITS button Press the Gate 1 right button to move gate to the desired OPEN position. When gate is in the desired position, press the LEARN LIMITS button again. Control board will beep. Press the Gate 1 left button to move gate to the desired CLOSED position. When gate is in the desired closed position, press the LEARN LIMITS button again. Press the Gate 1 left button to move gate to the desired OPEN position. When gate is in the desired position, press the LEARN LIMITS button again. Control board will beep. When the SET CLOSE LIMIT LED blinks, press the Gate 1 right button. When gate is in the desired closed position, press the LEARN LIMITS button. The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section.) Test the limits by pressing the SBC to open and close the gate. Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 K6 K2 F3 10A 32V D1O OPEN EDGE/ PHO T O OPEN PHO T O CLOSE PHO T O R227 R2O7 Z2 O R223 P1 Z9 Z8 F2 F6 D4 D2 R9 C64 JMPR1 R224 U4 CONTROL INPUTS FORCE TIMER TO CLOSE OFF MAX OPEN SINGLE BUTTON RESET STOP SHADOW INTERRUPT CHGR OVLD COM COM COM FUSE OPEN LOOP INPUTS POWER BATT 2 BATT 1 F1 20A 32V R35 D9 Z3 Z4 U3 D1 F5 C11 C13 C12 D15 R4 C2 R1O1 R1OO R9O K1 Q9 R196 Q22 D8 K3 K4 D21 D22 C4 ACCESSORY OVLD D6 JMPR2 MOV1 MOV2 DB1 U2 Z12 24 VAC/ SOLAR INPUT GATE 2 ACCESSORY POWER MAGLOCK ALARM GATE 1 C C NC NO NO GRN WHT YEL BLU RED BRN GRN WHT YEL BLU RED BRN F4 10A 32V F7 24V COM OVLD TIMER RUNNING GATE 2 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS DIAGNOSTIC GATE 1 J4 LEARN XMITTER MAGLOCK ON OFF D4 D2 U4 D9 Z3 Z4 U3 D1 D6 OFF SET OPEN LIMIT EN T RESET BUTTON SET CLOSE DIAGNOSTIC GATE 1 SET CLOSE DIAGNOSTIC GATE 1 SET CLOSE DIAGNOSTIC GATE 1 SET CLOSE DIAGNOSTIC GATE 1 With the gate in the CLOSED position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink). With the gate in the CLOSED position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink). LEARN LIMITS button PROGRAM OPEN PROGRAM CLOSE PROGRAM OPEN PROGRAM CLOSE NOTES: • The gate with the longer travel span (opening) must be set as the primary gate (GATE 1). • If one gate is overlapping the other, the g...
Dieses Handbuch ist für folgende Modelle:Safety Gate - LA412 (7.84 mb)