Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Genie, modell Excelerator 3531835447

Hersteller: Genie
Dateigröße: 4.17 mb
Dateiname: 949b5582-9217-4ed9-aabc-353a7609b1cf.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance. This Opener includes parts and supplies needed to install in most garages and connect to most garage doors. There are many variations of garages and garage doors. A few additional parts and supplies may be needed to install Opener into your garage and connect to your garage door. While checking items listed below, note any additional items you will need. TOol ued _ t_i ectio_s • 12'+ Tape Measure . Pencil . Ladder . Level Check condition of vertical stile in center of door, and its connection to door's top and bottom beams. A If door frame is nailed together and not a solid connection, door frame must be braced or reinforced before installing Opener. B If door is"lightweight" (made with frame and skin -not solid), door (including door frame) must be braced or reinforced before installing Opener. C A door opener reinforcement bracket may also be needed to connect garage door to Opener's Door Bracket. This Opener is designed for installation on a properly braced sectional door or solidly braced one-piece door. D Contact your Genie Factory Authorized Dealer or dealer of your garage door for any necessary bracing and a door opener reinforcement bracket (if needed) before proceeding. E If you have a wooden door, measure door's thickness. (1/4" x 2") Lag Screws are included for installing Door Bracket onto door. If your door is less than 2"thick, brace door or use shorter Door Bracket Lag Screws (1/4" x 11/4"-not included) CHCK G._.6 ©oo_ ALIGH _EIU I")OPEB.T 01% A Raise door, check alignment and see if it moves freely (Figure 1). If door appears out of alignment, binds, or does not move smoothly, contact a Genie Factory Authorized Dealer or dealer of your garage door for repairs and adjustments to door mechanism. Raise door to 3' -4' above ground and carefully let go. Door should stay stationary. Slight movement is acceptable. More than slight movement means door is out of balance. Contact a Genie Factory Authorized Dealer or dealer of your garage door for repairs and adjustments SECTIONAL ._cj_DOOR'TORSION SPRINGS SECTIONAL DOOR, to door mechanism. I_ Torsion Springs C Check door type. Make _/_-_411-_. "J a note of whether it is a __ __-__, _ sectional or a one-piece __-_:_' door (Figure 2). _........ e ............ WARNING: If your door sticks,binds,or is out of balance,haveit adjustedbyaGenieFactory Authorized Dealer. Door springs,cables, pulleys,bracketsand associatedhardware are under extreme tension and can cause seriousinjury or death. NOTE The Excelerator Opener is equipped with an automatic Garage Door Balance Detection System. SeeTroubleshooting Guide on page 27. KEEP FEET CLEAR OF DOOR Sectional Door One-Piece Door Figure 1 Checking door balance ONE-PIECE DOOR, TRACKLESS EXTENSION SPRINGS Header Area ..................... ::]--+ _ Center Stile Figure 2 Note Door Type Rail Extension for 8' door Measure garage door height (7'-6", 8'-0", or taller) with tape measure. A If door height is 7'-6" or less,continue with Check Step 4. B If your door height is above 7'-6%make sure your rail is long enough to open the garage door. If there is any question contact your Customer Service Representative at 1-800-3S-GENIE. Figure 3 Rail Extension Kit CH CKDOOR t_AD R SECTIONAL DOOR NOTE The header is a heavily reinforced section of the wall just above the top of the garage door opening. A Find vertical center line of door and header: • Close door. • Measure door width at top. • Mark a point at center of door and on header directly above door. Draw a center line to connect points. B Find Header Bracket mounting height (Figure 4): (Do not attach Header Bracket). • Raise door, watching top edge of door and stop door when its edge reaches its highest point. • Measure distance ('H") from top edge of door to floor. -For sectional doors, add 2-1/2" to"H': Mark a point on center line. Bottom of Header Bracket will be installed here. ONE-PIECE DOOR -For one-piece doors, add 6" to"H': Mark this point on center line. Bottom of Header Bracket will be H+6" installed here. NOTE e For both types of doors: H i If the ceiling in your garage is so low that there is not at least a 3" space above the Header Bracket mountingpoint, contact a Genie Factory AuthorizedDealer. If a door spring is in the way, place the Header Bracket avove the spring. Do Not move the door spring. C Check wall for a stud or a solid header at your mark: Figure 4 Find Highest Point of Travel (if checking a finished wall, a stud finder may be helpful). • If location is above Header, a 2" x 6" board must be screwed to studs beside your mark with at least two Lag Screws and Flat Washers (not provided). • Transfer your mark to new mounting board. 120 Volt grounded outlet 4_ or wiring box within 3 feet of °"f_ Power Head. Check ceiling or space above where Opener Power Head will be mounted (Figure S): A Measure from garage door center line mark toward rear of...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien