Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Genie, modell INTELLIG 4024

Hersteller: Genie
Dateigröße: 11.33 mb
Dateiname: 98cc2710-7cef-45f6-b034-e8d1242218a7.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Follow the instructions on this page. ATTENTION If your garage door opener has a Serial Number sticker which looks like this, in which the first two numbers are 10 or higher, your opener will operate using this Series III wall control. MODEL AC SR3 THE GENIE COMPANY FCC ID: B8Q AC SR3 Residential Door Operator IC: 2133A-CSD1D 120V. 60HZ. 5A FOR HELP CALL 1-800-35GENIE OR WWW.GENIECOMPANY.COM S/N:10XXXXXXXXXXXX Wall consoles from other manufacturers may not work with openers of these serial number groups. Genie® Series I wall buttons and Series II wall consoles will not work with openers of this serial number group. CHAIN OR BELT - TENSION ADJUSTMENT WARNING • Observe all safety warning and precautions! • Disconnect power from opener and disconnect carriage in rail from bullet before beginning this task. Visually inspect the chain or belt every 6 months. NOTE: Tension adjustments should be made with the door in the down position and the carriage released. • At the center of the rail the chain or belt should not be resting on the rail. See adjustment illustration on right. – With the bullet NOT engaged to the carriage, tighten adjustment nut until chain/belt does not, at the center of the rail, rest on rail. Do NOT overtighten. • Is there rust on chain or frayed edges on belt? – Contact a trained door system technician for chain/belt replacement. • Are there kinks or twists in the chain or belt? – Contact a trained door system technician for chain/belt replacement. Tighten nut to increase tension on chain or belt Chain Chain Chain at center of rail Approx. 1/8" Adjustment required Correctly adjusted Belt Belt Belt at center of rail Approx. 1/8" Adjustment required Correctly adjusted BELT CHAIN ©2010 The Genie Company 12/2010 21 REMOTE BATTERY REPLACEMENT Replace remote battery with a CR 2032 coin cell battery. 1. Open the remote case using a washer or coin that fits into the slot at the top of the remote. 2. Replace battery. 3. Align components and snap case closed. ADJUSTMENT GUIDE - SPEED SETTINGS FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM Speed settings are pre-programmed at the factory for the maximum speed. Speed settings should not need adjustment with this unit. However, travel speed for the opener in both the open and close directions can be adjusted to slower speeds to minimize normal wear for heavy sectional doors. NOTE: One piece doors are automatically set during Limits programming to the slowest speed and opener speed cannot be reset for one piece doors. CHANGE SPEED SETTING Use this guide to ADJUST powerhead SPEED settings. There are three (3) Speed settings available on this unit for the open and close directions. Door type (one piece or sectional), door weight and balance, and condition of door components / track affect door speed. Speed adjustment may not be available for some installations depending on these factors. PROGRAM 1. Press on the powerhead and hold until both SET lights turn steady ON. Release button. Lights go out and Round BLUE light comes ON. 2. Press two times and the Round BLUE and Long BLUE lights come ON. PROGRAM 3. Press once to enter the Speed Programming SET menu. The round LED will flash BLUE 3 times, then the current Speed setting for UP travel will display on the LEDs. See table below. 4. Press to raise or to lower UP Speed settings within the available range. NOTE: Faster door speeds may not be available. PROGRAM 5. Press to set UP Speed level. The long LED will SET flash BLUE 3 times, then the current Speed setting for DOWN travel will display on the LEDs. 6. Press to raise or to lower DOWN Speed settings within the available range. NOTE: Faster door speeds may not be available. PROGRAM 7. Press to set DOWN Speed level. Both LEDs flash BLUE to confirm. SET Speed Level Powerhead LEDs Round LED Long LED Default LED display is the current Speed setting LED Speed indicator colors Red Red Purple Purple Blue Blue Speed Level LED indicator colors MAXIMUM Red ON Red ON MID Purple ON Purple ON SLOW Blue ON Blue ON ©2010 The Genie Company 12/2010 ADJUSTMENT GUIDE - FORCE SETTINGS FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM CAUTION Door closing force is FACTORY set and requires no adjustment for normal operation. • Never increase the door closing force to compensate for a damaged door or a binding door track. • Never adjust force to compensate for a broken door spring. • Perform monthly CONTACT REVERSE TEST as described on page 18. Force settings are pre-programmed at the factory and "learned" during the Open/Close Limit settings steps. Some additional Force may be increased. For normal use, Force settings should not need adjustment with this unit. However, conditions that might suggest an adjustment is necessary are; Doors with very stiff weather seals. Doors that start down, then STOP and reverse before they close. Doors that start up, but STOP before they completely open. CHANGE FORCE SETTING Use this guide to ADJUST powerhead FORCE settings. NOTE: There are nine (...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - INTELLIG 4024H (11.33 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien