Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Genie, modell INTELLIG 1000 3024

Hersteller: Genie
Dateigröße: 11.3 mb
Dateiname: 1ecbf36d-363b-4ce0-9c87-4736eb7d39b1.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


6. Locate the wall console: • Within sight of the garage door, • At minimum height of 5 feet so small children are not able to reach it, and • Away from all moving parts of the door. 7. Install the Entrapment WARNING Label next to the wall console in a prominent location. 8. After installing the opener, the door must reverse within 2 seconds when it contacts a 1-1/2 inch high object (or a 2 x 4 board laid flat) on the floor. INFRARED PROTECTION FUNCTION 1. When garage door is opening, its movement will not be influenced if the Safe-T-Beam® is obstructed. 2. If the Safe-T-Beam® is obstructed before the garage door fully closes, the door will not close. 3. When the garage door is closing, if Safe-T-Beam® is interrupted by person or obstacle, the garage door will stop its downward travel and reverse automatically to its fully opened position. 4. Remove Safe-T-Beam® obstruction. 5. If the Safe-T-Beam® System fails, loses power, or is installed improperly, press and hold the wall console "open/close" button until the door reaches its fully closed position. If you release the "open/close" button on the wall console during the closing movement the door will reverse automatically to its fully opened position. ©2010 The Genie Company 12/2010 WARNING • Make sure doorway is in view and clear of obstacles and people to avoid injury or damage to property. • DO NOT operate this unit from wall console before LIMITS and FORCE are set. Severe damage to the opener can occur. • The bullet MUST be engaged to carriage BEFORE setting limits. See Installation Poster (if provided) or refer to pages 11 and 19. NOTE: If bullet has NOT been engaged to the carriage, do so now. 6 ©2010 The Genie Company 12/2010 PROGRAM SET — + SETTING & TESTING LIMITS AND FORCE The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making adjustments using the panel located on the bottom of the powerhead. Begin with Step 1 and continue through Step 10. Door Force is set during the final Open/Close cycle of these steps. The powerhead will automatically set door speed at slow if the distance between limits is less than 6 feet. Once Limits and Force are set DO NOT use the or buttons to open or close door. A) CLOSE DOOR TRAVEL LIMIT NOTE: You can start and stop door movement using either buttons until door is in correct open or closed position. Watch door move PROGRAMMING LIMITS & FORCE (Continuing from Installation Poster if provided) 1 OGRAM SET — + 5 PROGRAM SET — + PRESS and HOLD SEE BOTH Blue LEDs come ON SEE round Blue LED come ON SEE round Blue LED flashing RELEASE 1 2 3 4 NOTE: If one or both LEDs come ON RED at this time, Limits programming menu was not entered properly. You must exit programming and restart. To exit the programming function wait 30 seconds for the programming to time out. PRESS and RELEASE Please note that there is a 30 second timeout between each programming step. A programming timeout during these steps has occured when two RED flashing LEDs appear. In the event of a timeout please restart at Step 1. NOTICE IF DOOR BECOMES OBSTRUCTEDI PULL DOWN ON HANDLE PROGRAM SET — PRESS and RELEASE SEE long Blue LED come ON If RED LED comes ON - STOP and exit programming. PRESS and HOLD until door is FULLY CLOSED then RELEASE ©2010 The Genie Company 12/2010 7 PROGRAM SET — SEE long Blue LED flashing 6 Watch door move RAM SET — + B) OPEN DOOR TRAVEL LIMIT NOTICE IF DOOR BECOMES OBSTRUCTEDI PULL DOWN ON HANDLE DOOR CLOSES DOOR OPENS Door Limits are set. Both LEDs flash Blue and go OFF. Continue with Step 9 SET FORCE. SET FORCE Force is set automatically with first full CLOSE/OPEN door operation. 7 8 9 10 Perform a successful CONTACT REVERSE TEST and then continue with remote programming. NOTE: To reset LIMIT settings, repeat Steps 1-10. PRESS and RELEASE On Wall Console PRESS and RELEASE PROGRAM SET — NOTE: You can start and stop door movement using either buttons until door is in correct open or closed position. PRESS and RELEASE On Wall Console PRESS and RELEASE PRESS and HOLD until door is FULLY OPEN then RELEASE 8 ©2010 The Genie Company 12/2010 1 2 3 4 CONTACT REVERSE TEST The Force and Limit settings on the previous page MUST be COMPLETED before Contact Reverse testing. 1. Test. • Open garage door using wall console. – Place a 2" x 4" board (laid flat) under center of garage door opening. • Close garage door using wall console. • When door contacts board, the door must stop (within 2 seconds) and reverse direction returning to open position. 2. Adjustment. • If the door: – Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit. – Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit. • Test again. Repeat as necessary until door reverses upon contacting board. WARNING A moving door ca...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - INTELLIG 1000 3024H (11.3 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien