Hersteller: Lumex Syatems
Dateigröße: 3.78 mb
Dateiname: ProductAdditionalInfoItemOriginal323.pdf
|
Anleitung Zusammenfassung
Warning: This product should not be used without proper instruction from a health care professional. Warning: The Tilt-in-Space and Drop Arm Recliners have a 250 lb. maximum user weight capacity. Warning: Casters must be locked at all times, except during transit. Warning: GF/Lumex assumes no responsibility for damage or injury caused by the improper installation, assembly or use of these products. Note: All dimensions and specifications are subject to change without notice. CARE & MAINTENANCE Every three months: • Check and clean casters • tighten nuts • check brakes on casters • • check and clean lock recline mechanism • Check recliner mechanism for operation in all positions with assistant seated in recliner. For upholstery maintenance and stain removal, the following hints will be helpful: Ordinary Dirt: Wash with warm water and a mild soap or detergent. Stubborn Dirt: Using a soft bristle brush, follow directions above. Ground-in Dirt: Scrub with powdered cleanser or similar detergent. Chewing Gum: Scrape carefully; remove with kerosene or naphtha. Nail Polish and Remover: Blot immediately to prevent damage. Ball Point Pen: Blot immediately with a white cloth dampened in water or mineral oil. Paint, Shoe Polish, Heel Marks: Remove immediately! Use a white cloth dampened in kerosene, naphtha or turpentine. Do not use paint remover or liquid brush cleaners. Tars, Asphalt, Creosote: Remove to prevent staining. Clean area with kerosene or naphtha. Caution: When using kerosene or naphtha, do so in a well ventilated area and keep away from fire and flame. Waxing and Refinishing: Improves wearability. Use any quality paste wax. Excrement: Remove immediately! Clean with a diluted solution of 10% (or less) of bleach or Clorox. 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions UNPACKING INSTRUCTIONS 1. Unpack and inspect contents for shipping damage or missing parts. If parts are damaged or missing, contact your dealer immediately. The contents of this package should be: • One (1) Recliner frame with upholstered seat. • One (1) Upholstered back. • Two (2) Upholstered side panels. • Two (2) Pins with wire rings. 2. Do not remove the shipping support which is attached to the recliner’s upholstered back until after the recliner’s upholstered back has been assembled to the chair. 3. Save this booklet in a safe place for future reference. 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions Upholstered Back Cushion Elastic Band Figure 1 Shipping Support Clevis Pin Wire Ring Receiving Tubes Frame Key Ring Strap Hook Figure 2 Side Panel Cut-Out Push Here Slide Figure 3 BACK ASSEMBLY NOTE: Do not remove the shipping support which is attached to the recliners upholstered back until after the recliner's upholstered back has been assembled to chair. 1. Obtain upholstered back assembly. Remove the upholstered cushion from the metal back frame (See fig. 1). 2. Remove pins and wire rings from frame (See fig 1). 3. Slide back tubes onto receiving tubes on frame and tap down until holes in back line up with holes in frame (See fig. 1). 4. Replace pins and wire rings. Remove the shipping support and discard (See fig 1). 5. Slide the lower elastic band on back to cover pins. Position other straps evenly. The 2" elastic bands can be adjusted for custom comfort. 6. At the bottom of the cushion you will find two elastic straps with key rings on the ends (one on each side). Replace back cushion over metal frame. Attach each ring to the hook on the frame next to the seat rings (See fig 2). SIDE PANEL ASSEMBLY 1. Face the side panel cut out towards the front of the chair. 2. Line up the panel’s spring clips with the round tubes on the frame. Push against the panels side until the clips are secured to the frame. 3. Slide the panel up or down until the panel is flush with the top of the frame (See fig 3). 4. Repeat above steps for the opposite side. 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions To lock swivel and wheel Figure 4 To unlock Figure 5 To lock swivel CASTER OPERATION NOTE: This chair is equipped with four swivel casters for improved maneuverability. The rear casters are also equipped with locking features. Lock: To prevent the rear casters from swiveling and wheel turning, step on the rear pedal of the caster until it latches (See fig 4). Unlock: Step on middle button to unlatch (See fig. 4). SWIVEL LOCK PEDAL OPERATION NOTE: The swivel lock feature will aid the chair in rolling straight. Lock: To engage, push down on black swivel lock pedal and roll the recliner forward (See fig. 5). Unlock: Lift on the side of the pedal. DROP ARM OPERATION Warning: Before operating, insure that the patients extremities (i.e., hands, legs, limbs) are clear of the path of the armrest. NOTE:There are three armrest positions. To lower or raise the armrest, locate the push button on the side of the chair. Press the button to release and adjust armrest to the desired position...
Dieses Handbuch ist für folgende Modelle:Auto-Kindersitze - ORTHO-BIOTIC PREFERRED CARE 565DG (3.78 mb)