Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Lumex Syatems, modell ORTHO-BIOTIC PREFERRED CARE 565DG

Hersteller: Lumex Syatems
Dateigröße: 3.78 mb
Dateiname: ProductAdditionalInfoItemOriginal323.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Use handgrip to adjust recliner to desired position. Engage recliner stop. Figure 8 Figure 9 OPERATION OF THE POSITION MECHANISM NOTE:Casters must be locked. 1. To hold recliner in any position, rotate handle to point up (See fig. 8). 2. To release position mechanism, turn the handle to point down (See fig. 9). NOTE:The position mechanism is factory set. If the position mechanism does not hold, follow Adjustment Instructions for the position mechanism. The plate has 5 position marks for repeatable positions (See fig. 13). 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions Figure 10 Frame Key Ring Strap Hook Figure 11 Figure 12 565G UPHOLSTERY REMOVAL AND REPLACEMENT BACK CUSHION To remove: Release the two elastic straps which hold the button of the cushion to the back frame with small wire clips (See fig. 10). Grip top of cushion near back frame handgrips and slide up and off. To replace: Reverse procedure. SEAT-LEG CUSHION To remove: Release the two elastic straps which hold the cushion to the back frame with small wire rings (See fig. 11). Adjust the chair into the semi-recline position. Flip the seat cushion forward and release the two hooks which hold the cushion to legrest frame (See fig. 12). Slide the cushion downward and forward. To replace: Reverse procedure. ARM PANELS To remove: Grip the steel rod at the bottom of the side panel, located near the front of the side frame. Gently slide the rod backward. Flex the rod slightly until it disengages (See fig. 12). Detach the four screws from under the side frame arm plate. To replace: Reverse procedure. 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions RECLINER POSITIONING MECHANISM TROUBLE-SHOOTING ADJUSTMENT INSTRUCTIONS FOR POSITION MECHANISM NOTE: Never lubricate the position mechanism assembly. 1. Turn the position adjustment handle down to the release position, and remove clevis pin and wire ring from top of assembly. (See fig. 13). Slide 2. Slide positioning plate up, and turn square washer clockwise until snug (See fig. 13). 3. Slide the positioning plate down over square washer. Replace clevis pin and wire ring. 4. The position mechanism's handle should engage at about the halt way point. If more tension is desired, repeat the above procedure. Figure 13 Clevis ring and wire ring Positioning plate Square washer 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions TILT-IN-SPACE GAS SPRING TROUBLESHOOTING Bracket Assembly Gas Spring CylinderCable Nut In Out Rue Ring Figure 14 Clevis Pin Engage as shown Cable Figure 15 Bracket Assembly PROBLEM: If the chair actuates without squeezing the release lever, the cable assembly needs to be adjusted. CORRECTION: 1. Lean the chair on its side and remove clevis pin and wire rue ring that secure the top of the gas spring to the frame. Do not remove the cable. 2. Loosen the nut above the gas spring bracket. Rotate the gas spring out of the bracket (counterclockwise) 1/2 turn. Retighten nut on bracket, and reassemble the gas spring back to the frame. Check that cable is snapped into bracket (See fig. 14). 3. Test the operation of chair. If the chair still actuates without squeezing release lever, repeat the above procedure. PROBLEM: If the chair does not actuate with a person in the chair while squeezing the release lever and pushing on the back, then the cable is too loose and the assembly needs to be adjusted. CORRECTION: 1. Ensure the cable is properly engaged onto the bracket assembly. If cable is not engaged on bracket, engage as shown in figure 15. 2. With a person in the chair, recheck cable. If problem persists, go to step 3. 3. Lean the chair on its side and remove clevis pin and wire ring that secure the top of the gas spring to the frame. Do not remove the cable. 4. Loosen the nut above the gas spring bracket. Rotate the gas spring into the bracket (clockwise) 1/2 turn. Retighten nut on bracket and reassemble the gas spring back to the frame (See fig. 14). 5. Test the operation of chair. If the chair does not actuate with a person in the chair while squeezing the release lever, repeat steps 3-5. 565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions Release Lever Under Cusion Push Handle Up Position CORRECT TILT POSITIONING FOR TILT-IN-SPACE NOTE: The Tilt chair is attendant operated only. For chair to operate properly, a person must be in the chair. To tilt the chair back: 1. Stand behind the chair, and locate the release lever under the push handle. 2. Squeeze the lever while pushing down on the back. Once the desired position is attained, release the lever to lock into position (See fig. 16). To bring the chair up: 1. Stand behind the chair, and locate the release lever under the push handle. 2. Squeeze the release lever and lift the back up. Once the desired position is attained, release the lever to lock into position (See fig. 16). Legrest Down Legrest Up LEGREST OPERATION FOR TILT-IN-SPACE To lift legrest: S...

Dieses Handbuch ist für folgende Modelle:
Auto-Kindersitze - ORTHO-BIOTIC PREFERRED CARE 565TG (3.78 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien