Login:
Sortierung : Dateiname ↑   heruntergeladen   Bewertung   Dateigröße ↑  
heruntergeladen wurde: 138   Dateigröße: 444 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

The RM7800/RM7840 system consists of a Relay Module. Keyboard Display Modules (standard with RM7800), Dust Cover (standard with RM7840), Subbase, Amplifier, and Purge Card. Options include DATA CONTROLBUS MODULE™, Remote Display Mounting, First- Out Expanded Annunciator and Communications through Modbus™. Functions provided by the RM7800/RM7840 include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and troubleshooting. The RM7800/RM7840 is a

heruntergeladen wurde: 5   Dateigröße: 87 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

— — 2. Check for line voltage power at the oil primary control. Voltage should be 120 Vac. — — 3. Check indicator light with burner off, no call for heat (no flame). Indicator light is on. Cad cell or controller is defective, sees external light or connections are shorted. Go to step 4. Indicator light is off. Go to step 5. 69-1233—2 6 R7184A,B,P,U INTERRUPTED ELECTRONIC OIL PRIMARY R7184A,B,P,U INTERRUPTED ELECTRONIC OIL PRIMARY 4. Shield cad cell from external light. Indicator light turns off.

heruntergeladen wurde: 0   Dateigröße: 170 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

Bubbles indicate gas leak. 3. If leak is detected, tighten pipe connections. 4. Stand clear of main burner while lighting to prevent injury caused from hidden leaks which could cause flashback in the appliance vestibule. Light main burner. 5. With main burner in operation, paint pipe joints (including adapters) and gas control inlet and outlet with rich soap and water solution. 6. If another leak is detected, tighten adapter screws, joints, and pipe connections. 7. Replace part if leak can not b

heruntergeladen wurde: 29   Dateigröße: 87 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

The primary controls fuel oil, senses flame, controls ignition spark and notifies a remote alarm circuit when in lockout. The R7184 can be used with both hydronic and forced air systems. When used with hydronic systems, line voltage switching Aquastat® Controllers normally provide for the starting and stopping of the combustion sequences. With forced air systems, both mechanical and electronic low voltage thermostats control the starting and stopping of the combustion process. Some hydronic and

heruntergeladen wurde: 0   Dateigröße: 187 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

Recheck ignition sequence as follows: • Reconnect main valve wire. • Set thermostat to call for heat. • Watch ignition sequence at burner. • If spark still does not stop after pilot lights, replace ignition module. • If main burner does not light or if main burner lights but system locks out, check module, ground wire, and gas control as described in control module instructions. 3 60-0653—8 Fig. 7—Example of unsatisfactory pilot flames. Fig. 7—Example of unsatisfactory pilot flames. APPEARANCE C

heruntergeladen wurde: 5   Dateigröße: 87 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

Location 1. Mount on a 4 in. by 4 in. junction box, directly on the main burner or inside the appliance cabinet. In replacement applications, mount in the same location as the old control. See Fig. 1. Make sure the operating temperatures are within the ambient temperature range (see Specifications section). 2. Before mounting the control, make line voltage connections as shown in Fig. 2 through 7. Splice lines with solderless connectors. Do not exceed load ratings shown on the device label. 3. I

heruntergeladen wurde: 13   Dateigröße: 489 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

FEATURES • Q179A is a gas pilot assembly with a flame electrode (rod) and ignition electrode, making it suitable for applications requiring an interrupted or intermittent electrically ignited gas pilot burner. • Q179A1183 is an “I” port burner with an ignitionelectrode (spark) only. • Q179B has only the flame electrode and is suitable for use in continuous pilot applications. • Primary aerated type burner is equipped with stainless steel fins that provide the proper flame rod area to ground area

heruntergeladen wurde: 4   Dateigröße: 219 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

2. Extinguish any flame. 3. Open lid. 4. If odor continues, immediately call your gas supplier or fire department. INSTALLER: Please leave these instructions with the consumer. CONSUMER: Retain for future reference. BRICK OPENING: 8 3/4" x 14 1/4" x 4" deep. Side shelves and connector kits for mounting side burners on portable carts or in countertop enclosures are packaged separately. SIDEBURNER SHELF MODELS #25326-016 & #25336-016 DROP-IN MODELS #3275 & #3280 INSTALLATION AND OPERATING INSTRUCT

heruntergeladen wurde: 7   Dateigröße: 187 kb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

Use 221° F [105° C] minimum thermoplastic- insulated wire for the ground leadwire (asbestos insulation is not acceptable). 2. A male 1/4 in. [6 mm] quick-connect terminal is provided on Honeywell ignition modules. Fasten female quick-connect to wire end at ignition module. 3. Strip other end and fasten under igniter-sensor mounting screw. 4. If necessary, use shield to protect lead from radiant heat of burner. 5. The pilot burner serves as the grounding area for the flame signal. Run lead from p

heruntergeladen wurde: 5   Dateigröße: 1 mb   Hersteller: Honeywell  
Kategorie: Konvektionsöfen
@name

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2 Fireye C, D, and E-Series Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6 Fireye P-Series Section III . . . . . .