Anleitung Honeywell, modell BC7000L1000
Hersteller: Honeywell Dateigröße: 1.25 mb Dateiname: 47a64a3b-8d20-47b7-8368-9bb30baf5840.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2 Fireye C, D, and E-Series Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6 Fireye P-Series Section III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Honeywell R4126, R4127, R4181 Section lV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Honeywell R4140, R4150 with 20 Terminal Subbase (120 V only) Section V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...29 Honeywell R4150 with 13 or 15 Terminal Subbase 1. Installer must be a trained, experienced, flame safeguard control service technician. 2. Disconnect power supply before beginning installation to prevent electrical shock and equipment damage. 3. All wiring must comply with applicable local electrical codes, ordinances, and regulations. 4. Voltage and frequency of the power supply and flame detector(s) connected to this control must agree with those marked on the device. 5. Loads connected to the control terminals must not exceed those listed in the SPECIFICATIONS section. 6. All external timers must be listed or component recognized by authorities having jurisdiction, for the specific purpose for which they are used. 7. Perform all required checkout tests after installation is complete. IMPORTANT For on-off, gas-fired systems, some authorities having jurisdiction prohibit the wiring of any limit or operating contacts in series with the main fuel valve(s). P.G. Form Number 66-6002—4 Rev. 6/89 ©Honeywell Inc. 1989 SECTION I SECTION I DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Disconnect wires as they are marked. 4. Remove old subbase. 5. Mount Q520A subbase. 6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. For example: To convert a Fireye 70D10 to a BC7000, the wire marked “P” would connect to terminal #3 on the Q520. The wire marked “8” would connect to Q520 terminal #15. 7. The symbol “ “ designates a footnote. Study these footnotes carefully. 8. Plug in the BC7000. Make sure you select the proper amplifier, detector and program module for the application. FIREYE 70D10/26CF6-5022/26 CU6-5065 EP160/EP161/EP170 TO BC7000L/PM720L2004 or 1030 FIREYE 24CJ5 - 5010/5011/3010/3011 25CU6 5062/5063/RS-2E 70D30/26CF6 5020/5021/1010/1011 EP380/EP381/EP390 TO BC7000L/PM720M2002 FIREYE 24CJ5 5015 70D20/26CF6 5023/25 CU65055 EP260/EP261/EP270 TO BC7000L/PM720G2005 SECTION II SECTION II DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Disconnect wires as they are marked. 4. Remove old subbase. 5. Mount Q520A subbase. 6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. For example: To convert a Fireye 26RJ81016 to a BC7000, the wire marked “B” would connect to terminal #10 on the Q520. The wire marked “W” would connect to Q520 terminal #14. 7. The symbol “ “ designates a footnote. Study these footnotes carefully. 8. Plug in the BC7000. Make sure you select the proper amplifier, detector and program module for the application. 6 FIREYE 26RJ8 1016, 1016T 26RJ8 1012, 1012T, 6012, 6012T TO BC7000L + PM720G2005 FIREYE 25RLJ84580 TO BC700L + PM720L1030 FIREYE 25RU8 6560, 6570,6580 26RJ8 6060, 6070,6080, 6160 TO BC7000L + PM720L1030 FIREYE 29RF5 1001, 1009, 6009 TO BC7000L + PM720G2013 26RJ8 6058, 6066, 6068 25RU8 6558, 6566 TO BC7000L + PM720G2005 FIREYE 26RJ8 1002, 1003, 1008, 1011, 1018, 6008, 6018 29RF5 1000, 1002, 1005, 1015, 1104 29RF5 6015 TO BC7000L + PM720G2005 SECTION Ill SECTION Ill DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Disconnect wires as they are marked. 4. Remove old subbase. 5. Mount Q520A subbase. 6. Connect wires to subbase per attached c...