|
Anleitung Zusammenfassung
Combustible locations, rear 18" , sides 20" NEVER USE A DENTED OR RUSTY L.P. OR BUTANE TANK. The pressure regulator and hose assembly supplied by this unit must be used. Contact manufacturer on back of this Manual for replacement parts. GRILL PLACEMENT CLEARANCE TO NON-COMBUSTIBLE CONSTRUCTION A minimum of 3" clearance from the back of the Grill to non-combustible construction is required for the lid to open fully DO NOT INSTALL THE GRILL IN COMBUSTIBLE ENCLOSURES!!_, LOCATION When determining a suitable location take into account concerns such as exposure to wind, proximity to traffic paths and keeping gas supply lines as short as possible. Locate the Grill only in a well ventilated area. Never locate the Grill in a building, garage, breezeway, shed or other such enclosed areas without an approved ventilation system. During heavy use the Grill will produce considerable smoke. PAGE 3 FEATURES DRILL! • IIU ©> IUU ©> •■Ub " © •■lib © • Commercial grade stainless steel 4 Stainless steel tube burners (3 burners on Pro-3) burners at 12,500 BTU's each Electronic ignition (batteries required) Stainless steel grill grates Warming rack stainless steel radiant system Double lined hood Thermometer Chrome plated knobs Chrome plated end caps Stainless Steel bezels Optional Rôtisserie System Width: 26 AND 30 inches Our 3 burner grill Fits standard 3 burner turbo cut-outs by Barbeques Galore PAGE 4 GAS HOOK UP IF OPERATING THIS UNIT OUTSIDE THE USA, PLEASE CONSULT YOUR LOCAL CODES! Never connect an unregulated gas line to the Grill Total gas consumption (BTU per hour) of the Grill with all burners on "HI" ( 37,500 BTU/HR PRO-3) AND ( 50,000K BTU/HR PRO -4 ) PRO-3L ORIFICES SIZE= 59 PR0-3N ORIFICES SIZE= 51 PR0-4L ORIFICES SIZE= 59 PR0-4N ORIFICES SIZE= 51 The installation of this Grill must conform with local codes or, in the absence of local codes, with the national fuel gas code L. P. TANK REQUIREMENTS A dented or rusty L. P. tank may be hazardous and should be checked by your gas supplier Never use a cylinder with a damaged valve. FOR BUTANE GAS TANKS CHECK THE LOCAL SPECIFICATIONS The L. P. gas cylinder must be constructed and marked in accordance with the specifications for L. P. Gas cylinders of the U. S. Department of Transportation (DOT). The cylinder must be provided with a shut off valve terminating in an L. P. Gas supply cylinder valve outlet specified, as applicable, for connection type Qcc1 in the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1. Manifold pressure: (operating): 10" W.C. CONNECTION All Grills using L. P. gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb. L. P. cylinder (18 1/4" high, 12 1/4" diameter). THE L. P. TANK IS NOT INCLUDED Hose and regulator assembly is shipped ready for connection to L.P. Tank. NATURAL GAS CONNECTION Natural Gas: Manifold connection: 1/2” NPT male with 1/2" coupling OPERATING PRESSURE: 4.0" W.C. Supply pressure 5" to 14" water column. If in excess of 14" W.C. a step down regulator is required. Check with your local gas utility or with local codes for instructions or installing gas supply lines.TO HOOK UP THE FITTINGS SUPPLIED WITH THE GRILL Use threading compound on male threads only. Do not use threading compound on the male end of the 1/2" NPT to 3/8"-flare adapter. Use a second pipe wrench to hold the grill inlet pipe to avoid shifting any internal gas lines of the grill. Ensure that the regulator arrow points in the direction of gas flow towards the unit, away from the supply. Do not forget to place the installer supplied gas shut-off valve in an accesible location. PARTS SUPPLIED WITH THE UNIT: (1) NAT GAS REGULATOR, (2) 1/2" NPT NIPPLE, PAGE 5 LEAK TEST TO TEST Make sure all control valves are in the "OFF" position. Turn the gas supply on. Check all connections from the supply line, or L.P. cylinder up to and including the manifold pipe assembly. Make a soap solution of one part liquid detergent and one part water. Apply the solution around the connection, valve, and tubing. Soap bubbles will appear where a leak is present. If a leak is detected, immediately turn off the gas supply, and tighten any leaking fittings, turn gas on, and recheck. If a gas leak is present, and you can not stop the leak, immediately turn off the gas supply and call your local gas supplier or the dealer where you purchased your Grill. Only authorized factory parts, or parts recommended by the manufacturer should be used on the Grill. Substitution WILL VOID THE WARRANTY The disconnected L. P. cylinders must have threaded valve plugs tightly installed, and must not be stored in a building, garage or any other enclosed area. The gas must be turned off at the supply cylinder when the unit is not in use. If the Grill is stored indoors the cylinder must be disconnected and removed from the Grill. Cylinders must be stored outdoors in a well ventilated ar...
Dieses Handbuch ist für folgende Modelle:Konvektionsöfen - PRO-3N (13.06 mb)
Konvektionsöfen - PRO-4L (13.06 mb)
Konvektionsöfen - PRO-4N (13.06 mb)