The trial for ignition (lockout) time expired withoutflame being established. b. The cad cell detected flame at the end of the Valve On Delay state. To reset the control from lockout click the button 1 second. NOTE: A recurrence of the above failure modes or a failed welded relay check could cause the control to enter a Hard Lockout state that must be reset onlyby a qualified service technician. To reset from Hard Lockout, hold the reset button for 15 seconds until the yellow light turns on. 5. Ignition Carryover: Once flame is established, the igniter remains on for 10 additional seconds to ensure flame stability. 6. Run: The flame is sustained until the call for heat is satisfied. The burner is then sent to Motor-Off Delay, if applicable, or it is shut down and sent to Standby. 7. Recycle: If the flame is lost while the burner is firing, the control shuts down the burner, enters a 60 second recycle delay, and repeats the ignition sequence. The control will continue to Recycleeach time the flame is lost, until it reaches a pre-settime allotment. The control will then go into HardLockout instead of recycle. This feature preventsexcessive accumulation of oil in the appliance firingchamber. 8. Motor-Off Delay: If applicable, the oil solenoid valve is turned off and the control delays turning the motor off for the set motor-off delay time before the control returns to standby. 9. Pump Prime: The igniter and motor are on with the oil solenoid valve energized for 4 minutes. During Pump Prime mode, the cad cell is disregarded, allowing the technician to prime the pump without having to jumper the cad cell. 6104BAFG R06 Page 15 Page 16 6104BAFG R05 Figure 11a. – Interrupted ignition, valve-on delay only (no motor-off delay) Figure 11b. – Interrupted ignition, valve-on delay and motor-off delay SAFETY AND OPERATING LIMITS LIMIT L1 L2 (VLV) VALVE L2 MOTOR L2 (MTR) L2 (IGN) IGNITER CAD CELL MOTOR IGNITER W R 80 70 60 50 50 70 80 60 OIL VALVE CAD CELL THERMOSTAT TR TW TR-TW JUMPER TR-TW TERMINALS LOCATED ON OPPOSITE SIDE OF CONTROL L1 SAFETY AND L2 OPERATING LIMITS LIMIT L1 L2 (VLV) VALVE L2 MOTOR L2 (MTR) L2 (IGN) IGNITER CAD CELL MOTOR IGNITER W R 80 70 60 50 50 70 80 60 OIL VALVE CAD CELL THERMOSTAT TR TW TR-TW JUMPER TR-TW TERMINALS LOCATED ON OPPOSITE SIDE OF CONTROL L1 L2 LIMIT L1 - LIMIT JUMPER Table 2 - Reset Button Operation If the burner is in the below state: Pushing the reset button will: Button Click (press < 1 second) Button Hold (press > 1 second) Button Hold (press 15+ seconds) Lockout Reset from Soft Lockout Reset from Restricted (Hard) Lockout Valve-on Delay, Trial for Ignition, Ignition Carryover Go to Pump Prime (see “Priming the Pump” above) Disable the Burner: Any time the burner is running, press and hold the reset button to disable the burner. The burner will remain off as long as the button is held. Enables Pump Priming: After the reset button has been held for 15 seconds, the button can then be clicked during the next ignition sequence to enter Pump Prime mode. Run (igniter is shut off) Yellow light fl ashes to indicate cad cell resistance. See “Cad Cell Resistance Indicator” for table of resistance values. Motor-Off Delay, Standby No action Pump Prime No action Exit Pump Prime mode and return to Standby Table 3 - Status Lights Light Color On Continuously Flashing Red Restricted (Hard) Lockout Soft Lockout Green Flame Sensed during normal operation (Could be stray light during standby) Recycle Yellow Control is in Pump Prime mode or Reset button currently held for 15+ seconds. Cad Cell resistance. See “Cad Cell Resistance Indicator” on page 18 for a table of resistance values. Reset Button Operation Table 2 explains what action the control will take when the reset button is pressed for different lengths of time during the various burner operating states. Burner Controls 6104BAFG R06 Burner Controls Typical Burner Wiring & Burner Sequence of Operation for R7184P Control. Refer to the appliance manufacturer’s wiring diagram for actual specifications. Figure 10. – Typical Burner Wiring 1. STANDBY. The burner is idle, waiting for a call for heat. When a call for heat is initiated, there is a 310 second delay while the control performs a safe start check. 2. VALVE-ON DELAY. The ignition and motor are turned on for a 15 second valve-on delay. 3. TRIAL FOR IGNITION (TFI). The fuel valve is opened. A flame should be established within the 15 second lockout time. 4. LOCKOUT. If flame is not sensed by the end of the TFI, the control shuts down on safety lockout and must be manually reset. If the control locks out three times in a row, the control enters restricted lockout. 5. IGNITION CARRYOVER. Once flame is established, the ignition remains on for 10 seconds to ensure flame stability before turning off. If the control is wired for intermittent duty ignition, the ignition unit stays on the entire time the motor is running. 6. RUN. The burner runs until the call for heat is satified. The burner is then...
Dieses Handbuch ist für folgende Modelle:Konvektionsöfen - UO-3 CV (1.43 mb)
Konvektionsöfen - UO-4 CV (1.43 mb)