Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Maxon Telecom, modell INDITHERM 100

Hersteller: Maxon Telecom
Dateigröße: 232.96 kb
Dateiname: E-inditherm-m-specs_instructions.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


HHV - sg = 0.6 [1] Combustion air: 15° C - 21 % O2 - 50 % humidity - sg = 1.0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel, and gas quality. Burner size & type 100 300 550 700 850 1100 1500 1800 back pressure [2] mbar Max. capacity [3] kW (HHV) 0 125 340 550 720 850 1050 1472 1800 1.5 110 285 500 675 775 880 1266 1693 Min. capacity [4] kW (HHV) 0- 1.5 5.0 6.0 10 15 15 25 25 25 Pilot capacity [5] kW (HHV) 0-1.5 7.5 10.0 15 25 25 40 40 40 Combustion air differential pressure [6] mbar 0 6.5 4.5 6.4 7.9 9 5 6.4 13 1.5 5 3.2 5 7.3 7.5 3.5 4.7 11.5 Combustion air flow m3/h 0 136 360 615 755 910 1100 1611 1850 1.5 119 304 545 728 831 920 1386 1740 Gas differential pressure at inlet [7] mbar 0 3.4 7.5 6.4 10.3 13.3 19.8 5.8 10 Gas differential pressure at test connection [8] mbar 0 2.7 6.7 5.4 7.1 12 17.7 5.5 9.3 1.5 2.1 4.7 4.5 6.3 10 12.4 4 8.2 Flame length [9] m 0-1.5 1 1.2 2 2.1 2 2.3 2.6 3-4 [1] sg (specific gravity) = relative density to air (density air = 1.293 kg/Nm3. [2] Back pressure = static pressure in the combustion chamber where the flame develops. Data in this table are given for 0 and 1.5 mbar back pressure.Combustion air flow valid for all listed maximum capacities. [3] Maximum capacity when firing at 3% vol. O2 level in the flue gas. [4] Minimum capacity without pilot gas. If lower minimum capacities are required, refer to chapter ‘minimum capacities’ in this section. [5] With direct ignition (no pilot), start capacity should be equal or higher than the stated pilot capacity. [6] Differential pressure measured between burner test connection and combustion chamber. [7] Gas differential pressures for natural gas at burner inlet. This pressure should be available at burner inlet throughout the entire capacity range. [8] Differential pressure to be measured between burner test connection and combustion chamber. [9] Flame lengths are derived from measured lab data. Actual flame lengths can differ slightly. .com combustion systems for industry MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-7 Low temperature burners -INDITHERM® E-m-7/08 Materials of construction 1 2 3 4 1 Housing Cast iron 2 Standard sleeve AISI 310 (1.4841) High temperature block Castable refractory 3 Blower housing Carbon steel 4 Motor mounting bracket Carbon steel .com combustion systems for industry MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved. Low temperature burners -INDITHERM® 1-2.3-8 E-m-7/08 Selection criteria Application details Because of the burner’s versatility there are numerous types of applications for INDITHERM® burners. All types of indirect-fired applications can be equipped with this simple, industrial burner. Among the major applications there are automotive paint-bake ovens and surface treatment, bakery ovens and dryers for the food industry. Available INDITHERM® burner versions and options INDITHERM® burners are designed to operate on natural gas only. All burners are available in ANSI and ISO ver...

Dieses Handbuch ist für folgende Modelle:
Konvektionsöfen - INDITHERM 850 (232.96 kb)
Konvektionsöfen - INDITHERM 1100 (232.96 kb)
Konvektionsöfen - INDITHERM 1500 (232.96 kb)
Konvektionsöfen - INDITHERM 1800 (232.96 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien