Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung Philips, modell HX4101/02

Hersteller: Philips
Dateigröße: 3.54 mb
Dateiname:
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The cord wrap can be used to store power cord in an organized manner. Replacement Brush head Replacing your brush head ever y 6 months is clinically proven to remove more plaque. Use only Sonicare Advance replacement brush heads. Environment HANDLE CONTAINS NICKEL CADMIUM BATTERIES. BATTERIES MUST BE RECYCLED OR DISPOSED OF PROPERLY. The batteries inside your Sonicare cannot be replaced, but are easily removed for recycling. At the end of product life and prior to disposal, please remove the batteries from the handle by following the instructions below. . To help protect our environment, we encourage you to recycle at approved recycling locations. Do not dispose of the batteries in normal household waste. Removing the batteries Please note that this process is NOT reversible. To remove the batteries yourself, you will need a flat-head (standard) screwdriver and a small towel. Basic safety precautions should be obser ved when following the procedure outlined below. Be sure to protect your eyes, hands, fingers and the surface on which you are working. 1 With the brush head still attached to the power handle, completely deplete the batteries of electrical charge by pressing the power button and running a brushing cycle until it stops. Repeatedly run brushing cycles until the handle will no longer activate the brush head. 2 3 Remove the brush head from the handle. Split the handle open by inserting the screwdriver head all the way through both slots on the top part of the handle throat, where the brush head was previously attached. 12 ENGLISH 4 Turn the screwdriver handle sideways, using twisting and prying motions, to crack open the handle along its side seams. C 5 Pull the 2 handle sections completely apart. C 6 Insert the screwdriver underneath the electronic circuit board in multiple places. C 7 Twist and pry the electronic circuit board loose until it is completely separated from the handle. C 8 Pry the 2 AA-sized cylindrical nickel-cadmium batteries loose by inserting the screwdriver on the sides of the two batteries in the locations shown in the figure. C ENGLISH 13 C 9 Use a twisting and prying motion to break the glue bond on the inside of the handle plastic and underneath the batteries. The 2 batteries are joined together with glue and will be lifted out together. Please note that this process is NOT reversible. For information about Sonicare's batter y recycling program or instructions on recycling your Sonicare, call 1-800-682-7664 (Nor th America) or, outside Nor th America, contact your local Philips Customer Care Center. Guarantee & service SEE SEPARATE Philips worldwide guarantee leaflet for standard guarantee. Guarantee Restrictions What is not covered under warranty: -Brush Heads -Damage caused by misuse, abuse, neglect or alterations -Normal wear and tear, including chips, scratches, abrasions, discoloration or fading. IMPLIED WARRANTIES ANY IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTI...

Dieses Handbuch ist für folgende Modelle:
Zahnbürsten - HX4011/10 (3.54 mb)
Zahnbürsten - HX4012/10 (3.54 mb)
Zahnbürsten - HX4002/20 (3.54 mb)
Zahnbürsten - HX4001/20 (3.54 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien