Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Philips, modell FlexCare HX6910

Hersteller: Philips
Dateigröße: 598.7 kb
Dateiname: hx6911_02_dfu_aen.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If you want to shorten the power cord, you can store excess cord in the cord wrap feature built into the charger base. 1 To separate the charger cover from the charger base, press the two gray snap bars on the charger base and pull the white charger cover upwards. 2 Wrap excess power cord around the gray charger base as shown in the picture. Be sure to wrap the cord on the inside of the two snap levers. 3 When you have stored the excess cord, guide the power cord through the small groove in the rear of the gray charger base. 4 Reattach the charger cover by pressing it down over the charger base until it snaps into place. Tip: For extra convenience during travel, you can remove the travel charger and use it without the charger cover and charger base. 1243EngliSh 9 Quadpacer® -The Quadpacer® is an interval timer that has a short beep and pause to remind you to brush the 4 sections of your mouth. Depending on the brushing mode or brushing routine you have selected, the Quadpacer beeps at different intervals during the brushing cycle. See the “Brushing instructions” and “Personalizing your brushing experience” sections. The Quadpacer feature on this model has been activated.To deactivate or reactivate the Quadpacer feature: 1 Place the handle with a brush head attached in the plugged-in charger. 2 Press and hold the Personalized brushing button until: AYou hear 1 beep to indicate the Quadpacer has been deactivated. BYou hear 2 beeps to indicate the Quadpacer has been activated. Note:The Quadpacer feature cannot be deactivated on the pre-programmed Go Care and Max Care brushing routines. Cord wrap on deluxe charger (select models) If your model includes the deluxe charger cover and base, the travel charger is pre-installed inside the cover. If you want to shorten the power cord, you can store excess cord in the cord wrap feature built into the charger base. 1 To separate the charger cover from the charger base, press the two gray snap bars on the charger base and pull the white charger cover upwards. 2 Wrap excess power cord around the gray charger base as shown in the picture. Be sure to wrap the cord on the inside of the two snap levers. 3 When you have stored the excess cord, guide the power cord through the small groove in the rear of the gray charger base. 4 Reattach the charger cover by pressing it down over the charger base until it snaps into place. Tip: For extra convenience during travel, you can remove the travel charger and use it without the charger cover and charger base. 1243EngliSh 9 4235.020.2275.6.indd 9 29-09-09 09:21 Cord wrap on sanitizer with integrated charger (select models) -If your model includes the sanitizer, you can store excess cord using the cord wrap feature built into the bottom of the sanitizer. Sanitizing (select models) -With the UV sanitizer you can clean your brush head after every use. Discontinue use of the sanitizer if the UV light bulb remains on when the door is open or if the Philips logo is broken or missing from the sanitizer. UV light can be harmful to the human eye and skin.This device should be kept out of reach of children at all times. Unplug the sanitizer and call Customer Service if the sanitizer gives off smoke or a burning smell while it is operating. 1 After brushing, rinse the brush head and shake off excess water. Do not place the travel cap on the brush head during sanitization. 2 To open the sanitizer door, press the door release button. 3 Place the brush head on one of the 2 pegs in the sanitizer. -Make sure the bristles of the brush head directly face the light bulb. Note: Only clean Sonicare ProResults brush heads in the sanitizer. 4 Make sure the sanitizer is plugged into a live outlet of appropriate voltage. 5 Close the door and press the green power on/off button once to select the UV clean cycle. Note:You can only turn on the sanitizer if the door is properly closed. Note:The sanitizer stops if you open the door during the sanitizing cycle. Note:The sanitizer cycle runs for 10 minutes and then automatically shuts off. ,The sanitizer is in operation when the blue light glows through the Philips logo and the UV clean LED flashes slowly. ,When the sanitizing cycle is complete, the UV clean LED light turns solid green and the sanitizer automatically shuts off. EngliSh 10 Cord wrap on sanitizer with integrated charger (select models) -If your model includes the sanitizer, you can store excess cord using the cord wrap feature built into the bottom of the sanitizer. Sanitizing (select models) -With the UV sanitizer you can clean your brush head after every use. Discontinue use of the sanitizer if the UV light bulb remains on when the door is open or if the Philips logo is broken or missing from the sanitizer. UV light can be harmful to the human eye and skin.This device should be kept out of reach of children at all times. Unplug the sanitizer and call Customer Service if the sanitizer gives off smoke or a burning smell while it is operating. 1 After br...

Dieses Handbuch ist für folgende Modelle:
Zahnbürsten - HX6902/02 (598.7 kb)
Zahnbürsten - HX6932/10 (598.7 kb)
Zahnbürsten - HX6911/02 (598.7 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien