Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung American Power Conversion, modell 10-80kW

Hersteller: American Power Conversion
Dateigröße: 2.46 mb
Dateiname: ASTE-6Z3SWD_R0_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


a Servicing of batteries should be performed or supervised by qualified service personnel of batteries and the required precautions. Keep unauthorized personnel away from batteries. b When replacing batteries, replace with the same number and type as installed. c CAUTION - Do not dispose of battery or batteries in a fire. The battery may explode. d CAUTION - Do not open or attempt to modify batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. e CAUTION - A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries. 5. Disconnect charging source prior to connecting or disconnecting battery terminals. 6. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance. The installation and use of this product must comply with all national, federal, state, municipal, or local codes that apply. If you need assistance, please, have your UPS model and serial number available and call APC’s toll free technical support at: 1-877-287-7835 (1-8772UPS- TEK). You can find additional product information on the APC World Wide Web site atSee Section 2.0: How to contact APC. WARNING! With reference to Local Code use: 1. Additional insulating material 2. Insulating tools Installation Guide APC Silcon 10-80kW 208/480V Battery Cabinet Contents: 1.0 Battery Cabinet 5 1.1 Safety - Warnings 5 1.2 Unpacking 5 1.2.1 Preparing the APC Silcon Battery Cabinet 5 1.2.2 Placing 5 1.3 Dimensions / Weights 6 1.3.1 APC Silcon Battery Cabinets for 10-80kW – 208V 6 1.3.2 APC Silcon Battery Cabinets for 10-80kW – 480V 6 1.4 Footprint (measurements in inch/mm) 7 1.5 Configurations 8 1.5.1 Battery Cabinet installed next to UPS 8 1.6 Assembly 9 1.6.1 Battery Cabinet next to UPS 9 1.6.2 Connection of more than one string 9 1.6.3 Battery Cabinet apart from UPS 10 1.7 Fusing - and Cable size 10 1.8 Terminals 12 1.9 Connecting 13 1.9.1 Before Starting Up 13 1.9.2 Connecting the APC Silcon Battery Cabinet and the APC Silcon UPS13 1.10 Example Diagram: APC Silcon UPS with battery cabinet 14 1.11 Parallel Connection 15 2.0 How to contact APC 16 3.0 Appendix 17 3.1 Battery Cabinet Style Definitions 17 3.1.1 Battery Layout Drawing Style A, Middle Shelf 18 3.1.2 Battery Layout Drawing, Style A, Bottom Shelf 19 3.1.3 Battery Layout Drawing, Style B1, Top Shelf 20 3.1.4 Battery Layout Drawing, Style B1, Middle Shelf 21 3.1.5 Battery Layout Drawing, Style B1, Bottom Shelf 22 3.1.6 Battery Layout Drawing, Style B1XR, Top Shelf 23 3.1.7 Battery Layout Drawing, Style B1XR, Middle Shelf 24 3.1.8 Battery Layout Drawing, Style B1XR, Bottom Shelf 25 3.1.9 Battery Layout Drawing, Style B3, Battery Cabinet A, Top Shelf 26 3.1.10 Battery Layout Drawing, Style B3, Battery Cabinet A, Middle Shelf 27 3.1.11 Battery Layout Drawing, Style B3, Battery Cabinet A, Bottom Shelf 28 3.1.12 Battery Layout Drawing, Style B3, Battery Cabinet B, Top Shelf 29 3.1.13 Battery Layout Drawing, Style B3, Battery Cabinet B, Middle Shelf 30 3.1.14 Battery Layout Drawing, Style B3, Battery Cabinet B, Bottom Shelf 31 3.1.15 Battery layout Drawing, Style B4, Top Shelf 32 3.1.16 Battery Layout Drawing, Style B4, Middle Shelf 33 3.1.17 Battery Layout Drawing, Style B4, Bottom Shelf 34 3.1.18 Battery Layout Drawing, Style C2, Top Shelf 35 3.1.19 Battery Layout Drawing, Style C2, Middle Shelf 36 Installation Guide APC Silcon 10-80kW 208/480V Battery Cabinet 3.1.20 Battery Layout Drawing, Style C2, Bottom Shelf 37 3.1.21 Battery Layout Drawing, Style C3, Top Shelf, Cabinet A 38 3.1.22 Battery Layout Drawing, Style C3, Middle Shelf Cabinet A 39 3.1.23 Battery Layout Drawing, Style C3, Bottom Shelf, Cabinet A 40 3.1.24 Battery Layout Drawing, Style C3, Stop Shelf Cabinet B 41 3.1.25 Battery Layout Drawing, Style C3, Middle Shelf Cabinet B 42 3.1.26 Battery Layout Drawing, Style C3, Bottom Shelf Cabinet B 43 3.1.27 Battery Layout Drawing, Style C2XR, Top Shelf 44 3.1.28 Battery Layout Drawing, Style C2XR, Middle Shelf 45 3.1.29 Battery Layout Drawing, Style C2XR, Bottom Shelf 46 Installation Guide APC Silcon 10-80kW 208/480V Battery Cabinet Battery Cabinet 1.0 Battery Cabinet 1.1 Safety - Warnings WARNINGS! The total system contains HAZARDOUS AC/DC VOLTAGES and is supplied from multiple power sources. Some terminals and components are live even when the system is switched off! ONLY qualified electricians are allowed to perform the installation according to national and local codes! NO APC Silcon UPS is allowed to have internal batteries when connected to an external bat...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien