Anleitung Associated Equipment, modell 9010

Hersteller: Associated Equipment
Dateigröße: 87.55 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. DANGER. Never alter AC cord or plug provided - if it will not fit outlet, have proper outlet installed by a qualified electrician. Improper connection can result in a risk of an electric shock. This battery charger is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in FIGURE (A). A temporary adapter, which looks like the adapter illustrated in FIGURE (C), may be used to connect this plug to a two-pole receptacle, as shown in FIGURE (B) if a properly grounded outlet is not available. The temporary adapter shouldbe used only until a properly grounded outlet can be installed by a qualified electrician. DANGER. Before using adapter as illustrated, be certain that center screw of outlet plate is grounded. The green-colored rigid ear or lug extending from the adapter must be connected to a properly grounded outlet - make certain it is grounded. If necessary, replace original outlet cover plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate and make ground connection to grounded outlet. NOTE: USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN. 2 20. OPERATING INSTRUCTIONS Before using review all safety and connection directions before using charger. Failure to do so can damage battery and cause serious injury or death. Manual Chargers Models: 9006, 9010 and 9050 FEATURES: All chargers come with a State of charge / Amp-meter 9006 — SELECT SETTING switch with the following selections; OFF, 6A–12V, 2A–12V and 6A–6V 9010 — SELECT SETTING switch with the following selections; OFF, 10A–12V, 2A–12V and 10A–6V 9050 — SELECT SETTING switch with the following selections; 55A START, 10A–12V, 2A–12V and 10A–6V CHARGE SETTING SWITCH USE: 55A START — Use this setting for starting a vehicle with a discharged battery. 6A and 10A–12V — Use this setting for charging large 12 volt batteries such as Automobiles, boats, etc. 2A–12V — Use this setting for charging small 12 volt batteries such as lawn tractor, motorcycles, etc. 6A and 10A–6V — Use this setting for charging 6 volt batteries, monitor battery continually, since this rating does not taper. OFF — Use this setting when battery charging is completed. Manual Charging: (12 volt only) This method is for a standard LEAD-ACID battery in good condition at 70°F. Never charge a frozen battery. Always terminate charge if battery temperature exceeds 120°F. 1. Determine battery size (see chart below) round down. 2. Determine battery state of discharge (see chart below) round down if possible. 3. Connect charger to battery per instructions in sections 16, 17 and 18. 4. Plug charger into wall outlet per instructions in section 19. 5. Determine charge time (hrs) = Battery size x State of discharge x 1.2 Example: battery is 450Cca (56 AH) and 12.2V Battery size is 4 State of discharge is .50 Time on Charge = 4 x .50 x 1.2 = 2.4 hrs If the battery state of charge is unknown then monit...

Dieses Handbuch ist für folgende Modelle:
Ladegerä - 9006 (87.55 kb)
Ladegerä - 9014 (87.55 kb)
Ladegerä - 9050 (87.55 kb)
Ladegerä - 9060 (87.55 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien