Anleitung Carrier, modell 30GX080-176

Hersteller: Carrier
Dateigröße: 107.65 kb
Dateiname: 30gx,hx-2si.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


30HX-900---009, 30GX-900---005 (50 or 60 Hz — 230-v Control) CONTENTS Page SAFETY CONSIDERATIONS ...................1 INTRODUCTION ..............................1 INSTALLATION ............................. 1-6 Step 1 — Examine Package Contents .........1 Step 2 — Install Piping .......................2 • REMOVE MINIMUM LOAD PORT PLUGS AND INSTALL FITTINGS • INSTALL PIPING • INSTALL BALL AND SOLENOID VALVES • CONNECT PIPING Step 3 — Dehydrate and Recharge Circuit .....3 Step 4 — Install Control Wiring ...............4 • 30HX UNITS • 30GX UNITS • ALL UNITS Step 5 — Configure Unit for Minimum Load Control ..............................6 Step6—Test Minimum Load Relay Outputs ...................................6 Step 7 — Adjust Setting of Minimum Load Ball Valve ..................................6 SAFETY CONSIDERATIONS Installing, starting up, and servicing air-conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location. Only trained, qualified installers and service technicians should install, start up, and service this equipment. When working on air-conditioning equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment. Follow all safety codes. Wear safety glasses and work gloves. Use care in handling equipment. Be sure power to equipment is shut off before performing maintenance or service. IMPORTANT: When removing refrigerant, use an approved refrigerant recovery device. Do not vent refrigerant into the atmosphere. INTRODUCTION The minimum load control accessory allows 30HX and 30GX chillers to have their capacities decreased below the standard fully unloaded condition. The accessory provides more precise control of leaving fluid temperature during light load conditions. The 30GX and 30HX chillers have a dual-circuit design. Each minimum load control accessory package contains the items required for both circuits. Because of an automatic lead/ lag feature on the chillers, the accessory should be installed on both circuits. INSTALLATION Step 1 — Examine Package Contents — Package includes solenoid valves, ball valves, Swagelok. connectors, and instructions. The kit for 30GX units also contains a junction box, junction box cover, and conduit. Examine each item. If any part is damaged or missing, file a claim immediately with the shipper. See Table 1 for accessory package contents and field-supplied material. Table 1 — Accessory Package Contents and Field-Supplied Material ACCESSORY PACKAGE ACCESSORY PART NUMBER COMPONENTS 30HX-900---008 30HX-900---009 30GX-900---004 30GX-900---005 Solenoid Valve (2) EF23JX212 (2) EF23JX231 (2) EF23JX212 (2) EF23JX231 Ball Valve (2) EP71BA201 (2) EP71BA201 (2) EP71BA201 (2) EP71BA201 Swagelok Connector (4) DC09CA307 (4) DC09CA307 (2) DC09CA307 (2) DC09CA307 Junction Box — — HX30FZ001 HX30FZ001 Junction Box Cover — — HX38ZZ001 HX38ZZ001 Watertight Conduit — — 99CD2121AC028 99CD2121AC028 FIELD SUPPLIED MATERIAL — REQUIRED PARTS (Ordered Separately) 5.8-in. OD Copper Tubing, Wiring, Conduit, Field Supplied Thread Sealant, Electrical Supplies Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 903 Catalog No. 563-056 Printed in U.S.A. Form 30GX,HX-2SI Pg 1 1-97 Replaces: New Tab 5c Step 2 — Install Piping Shut off all power to the unit, then lock out and safety- tag all disconnects before proceeding with installation. Remove refrigerant charge from circuits using an approved refrigerant recovery device before proceeding with installation. NOTE: The units have 2 circuits. Perform all of the following piping installation procedures on both A and B circuits. REMOVE MINIMUM LOAD PORT PLUGS AND INSTALL FITTINGS — Plugs must be removed from these ports and replaced with Swagelok. fittings. Note that plugs were factory-installed with Loctite. refrigerant-compatible sealant. Fittings should be installed with similar sealant on threads. 30GX — Cut plug end off of minimum load port braze nipple on discharge line, located between oil separator and condenser. Remove plug from minimum load port on cooler shell. See Fig. 1. Using thread sealant, install Swagelok fitting in minimum load port on cooler. Port on nipple in discharge line is reserved for a brazed connection. 30HX — Remove plugs from minimum load ports on the cooler shell and the condenser shell (30HXC) or oil separator (30HXA). See Fig. 2. Using thread sealant, install Swagelok fittings in minimum load ports. INSTALL PIPING — On 30GX units, install field-supplied 5.8-in. OD copper tubing between the Swagelok fitting on the cooler shell and the brazed nipple on the discharge line. On 30HX units, install field-supplied 5.8-in. OD copper tubing between the fittings on the cooler shell and condenser (30HXC) or oil separator (30HXA). Do not tighten fittings or braze tubing yet. TOP VIEW Fig. 1 — Installing Fittings, 30GX (Typical) 2 IN...

Dieses Handbuch ist für folgende Modelle:
Kühlen - 30HX076-271 (107.65 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien