|
Anleitung Zusammenfassung
4 and 5 for specific mounting hole location dimensions. WEIGHT DISTRIBUTION AT EACH MOUNTING HOLE, 50 HZ UNITS UNIT MOUNTING HOLES 30HK 30HL SIZE A B C D A B C D Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg 040 721 327 723 328 716 325 715 325 — — — — — — — — 050 838 380 840 381 832 377 830 376 534 242 526 238 531 241 529 240 060 853 387 855 388 847 384 845 383 550 249 551 250 545 247 544 247 NOTE: See Fig. 4 and 5 for specific mounting hole location dimensions. LOCATION OF MOUNTING HOLES Fig.9—Weight Distribution and Mounting Hole Location; 30HK,HL Units 30HWA,B 30HWC,S WEIGHT DISTRIBUTION AT EACH MOUNTING HOLE — Lb (kg) UNIT 30HW MOUNTING HOLE NO. 1 2 3 4 5 6 7 8 A018 185 (83.9) — A025 220 (99.8) — A028 240 (108.9) — A035 244 (110.7) — A040 270 (122.5) — B018 199 (90.3) — B025 238 (108.0) — B028 266 (120.7) — B035 271 (122.9) — B040 328 (148.8) — C,S018 171 (77.6) 136 (61.7) C,S025 196 (88.9) 144 (65.3) C,S028 211 (95.7) 160 (72.6) C,S035 216 (98.0) 161 (73.0) C,S040 240 (108.9) 185 (83.9) Fig. 10 — Mounting Hole Weight Distribution; 30HW Units 9 Table 1A — Physical Data; 30HK, HWB, HWC, and HWS Fluid-Cooled Units — English UNIT30HW-018*HW-025*HW-028*HW-035*HW-040*HK040HK050HK060OPERATINGWT(Approximate).lbHWB795950106510851310——— HWC,S12311358148415081702——— HK—————2830/ 2875† 3138/ 3340† 3340/ 3400† REFRIGERANT—lbR-22HWB12.515.017.518.523.2——— HWC,S35.037.042.042.047.0——— HK—Ckt1—————35/40†45/45†45/45† HK.Ckt2—————35/35†35/45†45/45† COMPRESSORModelNo.06DG53706E2150**06E726506E7175**06E729906E215006E6175,06E215006E6175NominalHp152025303520(ea)20,3030(ea) Quantity1111121(ea)2CylindersPerCompressor646664(ea)6,46(ea) CapacityControl—StandardNo.ofSteps32333444MinimumStepCapacity(%)33503333332520††33CapacityControl—WithOptionalHotGasBypassNo.ofSteps43444555MinimumStepCapacity(%)1010101010101010ReliefValveFlowRate—lbair/min—15.115.115.115.115.115.115.1COOLERPartNo.LL01SB006LL01SB007LL01SB009LL01SB009LL01SC00510HA40065410HA40066410HA400664DryWeight—lb6981105105145657726726FluidSide—psig300300300300300150150150RefrigerantSide—psig430430430430430235235235NetFluidVolume—Gal.1.41.62.12.13.313.115.215.2(includesnozzles) FluidConnections—in.GroovedEndInlet11.211.211.211.221.2333Outlet11.211.211.211.221.2333CONDENSER30HWB(WaterCooled) PartNo.LL01S-D001D002D003D004E004——— DryWeight—lb48627987153——— WaterSide—psig300300300300300——— RefrigerantSide—psig430430430430430——— NetWaterVolume—Gal.0.91.21.61.83.3——— (includesnozzles) WaterConnections—in.GroovedEndInlet11.211.211.211.221.2——— Outlet11.211.211.211.221.2——— 30HWC(WaterCooled) PartNo.09RW-400007400007400011400011400009——— DryWeight—lb532532560560624——— WaterSide—psig300300300300300——— RefrigerantSide—psig365365365365365——— NetWaterVolume—Gal.2.62.64.04.07.3——— ReliefValveFlowRate—lbair/min24.624.624.624.624.6.—— WaterConnections—in.WeldInlet21.221.221.221.221.2——— Outlet21.221.221.221.221.2——— 30HWS(WaterCooled) PartNo.09RW-400017400017400019400019400018——— DryWeight—lb532532560560624——— WaterSide—psig300300300300300——— RefrigerantSide—psig335335335335335——— NetWaterVolume—Gal.2.62.64.04.07.3——— ReliefValveFlowRate—lbair/min22.622.622.622.622.6.—— WaterConnections—in.WeldInlet21.221.221.221.221.2——— Outlet21.221.221.221.221.2——— 30HK(WaterCooled) PartNo.09RP-—————022/022†022/027†027/027† DryWeight—lb—————100010951190WaterSide—psig—————250250250RefrigerantSide—psig—————385385385NetWaterVolume—Gal.—————4.4/4.4†4.4/5.2†5.2/5.2† (includesnozzles) ReliefValveFlowRate—lbair/min—————25.925.925.9WaterConnections—in.WeldInlet—————21.221.221.2Outlet—————21.221.221.2NOTES: 1.Operatingweightincludesrefrigerantoperatingchargeandweightoffluidintheheatexchangers. 2.30HK,HWB,HWC,andHWSunitsareshippedwithfulloperatingcharge. 10 LEGEND ODS — Outside Diameter, Sweat *Unless otherwise noted, data is for HWB, HWC, and HWS units. †60 Hz/50 Hz units. **For 025 50 Hz units, compressor number is 06E2250, for 035 50 Hz units compressor number is 06E7275. ††With transfer switch set to compressor no. 2 position; 40% with transfer switch set to compressor no. 1 position. Table 1B — Physical Data; 30HK, HWB, HWC, and HWS Fluid-Cooled Units — SI UNIT30HW-018*HW-025*HW-028*HW-035*HW-040*HK040HK050HK060OPERATINGWT(Approximate).kgHWB360431483492594——— HWC,S554611668679766——— HK—————1284/ 1305† 1424/ 1514† 1514/ 1542† REFRIGERANT—kgR-22HWB5.76.87.98.410.5——— HWC,S15.916.819.119.121.3——— HK—Ckt1—————15.9/18.1†20.4/20.4†20.4/20.4† HK—Ckt2—————15.9/15.9†15.9/20.4†20.4/20.4† COMPRESSORModelNo.06DG53706E2150**06E726506E7175**06E729906E215006E6175,06E215006E6175NominalkW11.114.918.722.426.114.9(ea)14.9,22.422.4(ea) Quantity1111121(ea)2CylindersPerCompressor646664(ea)6,46(ea) CapacityControl—StandardNo.ofSteps32333444MinimumStepCapacity(%)33503333332520††33CapacityControl—WithHotGasBypassNo.ofSteps43444555MinimumStepCapacity(%)1010101010101010ReliefValveFlowRate—kgair/min—6.86.86.86.86.86.86.8COOLERPartNo.LL01SB006LL01SB007LL01SB009LL01SB009LL01SC00510HA40065410HA40066410HA400664DryWeight—kg31.336.747.647....
Dieses Handbuch ist für folgende Modelle:Kühlen - 060 (1.45 mb)
Kühlen - 30HK040-060 (1.45 mb)
Kühlen - 30HL050 (1.45 mb)