2. Alarms history 200 events can be recorded by TRACER CH532. Each record will give the fault description, the reset type, the order and the day and time of occurrence. Maintaining for 5 seconds give will access to the last event recorded. Then using allows the user to view the complete history. (refer to table 5 for possible messages) CG-SV01B-E4 Alarms Table 4 - Status, warnings and alarm messages No Messag e Reset Type Unit stat us Descr iption 1 No Alarm -Unit On See unit status on Main display 2 Ext. Ckt1 Stop -Circuit 1 Off Circuit 1 Off by Digital Input (Dual circuit units) 3 Ext. Ckt2 Stop -Circuit 2 Off Circuit 2 Off by Digital Input (Dual circuit units) 4 User Ckt1 Stop -Circuit 1 Off Circuit 1 Disable by Settings (via keyboard) 5 User Ckt2 Stop -Circuit 2 Off Circuit 2 Disable by Settings (via keyboard) 6 Remote Ckt1 Stop -Circuit 1 Off Circuit 1 Disable by Supervision 7 Remote Ckt2 Stop -Circuit 2 Off Circuit 2 Disable by Supervision 8 Clock Unit Stop -Unit Off Unit Off by Program (Hourly, Weekly) 9 Operator Stop -Unit Off Unit Off by Operator (via keyboard) 10 Ckt1 Defrost -Unit On Circuit 1 under defrosting 11 Ckt2 Defrost -Unit On Circuit 2 under defrosting 12 Warning Comp.1 Maintenance Manual Unit On 13 Warning Comp.2 Maintenance Manual Unit On Compressor running hours above the threshold defined in unit 14 Warning Comp.3 Maintenance Manual Unit On configuration.Each compressor start is equal to 3 running hours. 15 Warning Comp.4 Maintenance Manual Unit On 16 Alarm Air Sensor Auto Unit Off Defective Air sensor 17 Alarm Ckt 1 Fault Manual Circuit 1 Off Simultaneous manual reset faults CMP A1 and (B1 or C1) 18 Alarm Ckt 2 Fault Manual Circuit 2 Off Simultaneous manual reset faults CMP A2 and (B2 or C2) 19 Alarm Ckt1 HP Limit Auto Unit On Compressor B1C1 Off for high HP ckt1 20 Alarm Ckt1 Limiting Auto Unit On Compressor B1C1 Off for Hot water or low LP ckt1 21 Alarm Ckt2 HP Limit Auto Unit On Compressor B2C2 Off for high HP ckt2 22 Alarm Ckt2 Limiting Auto Unit On Compressor B2C2 Off for Hot water or low LP ckt2 23 Alarm Comp. A1 Fault Auto/Manual CMP A1 Off Manu if CMP A1 failure > 35 min or 6 failures within 3 hours 30 min 24 Alarm Comp. B1 Fault Auto/Manual CMP B1 Off Manu if CMP B1 failure > 35 min or 6 failures within 3 hours 30 min 25 Alarm Comp. C1 Fault Auto/Manual CMP C1 Off Manu if CMP C1 failure > 35 min or 6 failures within 3 hours 30 min 26 Alarm Comp. A2 Fault Auto/Manual CMP A2 Off Manu if CMP A2 failure > 35 min or 6 failures within 3 hours 30 min 27 Alarm Comp. B2 Fault Auto/Manual CMP B2 Off Manu if CMP B2 failure > 35 min or 6 failures within 3 hours 30 min 28 Alarm Comp. C2 Fault Auto/Manual CMP C2 Off Manu if CMP C2 failure > 35 min or 6 failures within 3 hours 30 min 29 Alarm Ext. Setpoint Signal Auto Unit Off Defective device or bad device configuration 30 Alarm Fan Protection 1 Auto Unit On Defective fan on the circuit 1 31 Alarm Fan Protection 2 Auto Unit On Defective fan on the circuit 2 32 Alarm HP Ckt1 Fault Manual Circuit 1 Off High Pressure Cut-Out circuit 1 33 Alarm HP Ckt2 Fault Manual Circuit 2 Off High Pressure Cut-Out circuit 2 34 Alarm HP Sensor Ckt1 Auto Circuit 1 Off Defective pressure sensor HP1 35 Alarm HP Sensor Ckt2 Auto Circuit 2 Off Defective pressure sensor HP2 36 Alarm Low Ambient Auto Unit Off Ambient temperature too low for unit operation 37 Alarm Low Water Temp Manual Unit Off LWT < antifreeze or INT (antifreeze-EWT)<=10°Cxsecond 38 Alarm LP Ckt1 Fault Auto/Manual Circuit 1 Off Suction pressure too low on circuit 1 39 Alarm LP Ckt2 Fault Auto/Manual Circuit 2 Off Suction pressure too low on circuit 2 40 Alarm LP Sensor Ckt1 Auto Circuit 1 Off Defective pressure sensor LP1 41 Alarm LP Sensor Ckt2 Auto Circuit 2 Off Defective pressure sensor LP2 42 Alarm Unit Fault Manual Unit Off All the compressors are defectives 43 Alarm Water Flow (**) Auto Unit Off No water flow. Reset by unit Off/On when pump Off 44 Alarm Water In Sensor Auto Unit On Defective Return water sensor 45 Alarm Water Out Sensor Auto Unit Off Defective Leaving water sensor 46 Alarm Water Pump1 Manual Unit On Defective water pump 1 47 Alarm Water Pump2 Manual Unit On Defective water pump 2 (**) When the unit is shut down after a waterflow alarm for more than 1 minute, it is necessary to switch the unit Off and On again to reset the fault. The fault will automatically reset if the water pump is still running. CG-SV01B-E4 Alarms Table 5 - History events record No Message Reset Type Unit status Description No History Air Sensor Auto Auto Unit On Unit Off No alarm was recorded Faulty sensor, out of range -30..+80°C (short circuit or open circuit) Water In Sensor Auto Unit On Faulty sensor, out of range -30..+80°C (short circuit or open circuit) Water Out Sensor Auto Unit Off Faulty sensor, out of range -30..+80°C (short circuit or open circuit) Lp Sensor Ckt1 Auto Circuit 1 Off Faulty sensor, out of range 0..10V, 0..1V,0..20mA or 4..20mA following configuration Hp Sensor Ckt1 Auto Circu...

Dieses Handbuch ist für folgende Modelle:
Kühlen - TRACER CH532 (563.89 kb)
Kühlen - TRACER CH532 (563.89 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien