This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means. After a power failure, the extactor will not go on again automatically. You can recommence operation by turning a knob or by pressing any key. Technical modifications reserved. Never allow children to play with the appliance. Do not let adults or children operate the appliance unsupervised: – if they are mentally or physically unable to use the appliance safely and correctly, – if they don’t have the knowledge and experience to use the appliance safely and correctly. Operating for the first time Before operating the appliance for the first time, please pay attention to the following notes: The appliance must be installed and connected by a specialist before it is operated for the first time. Conscientiously read through the operating and assembly instructions before operating the appliance for the first time. Remove the packaging from the appliance and dispose of it properly! Pay attention to the fact that there are accessories in the packaging! Keep packaging elements (e.g. plastic foil, styrofoam parts) out of the reach of children! Thoroughly clean the appliance before using it for the first time (see chapter “Cleaning and care”). Before operating the appliance for the first time, check that the mains connection is in proper working order. This appliance is labelled in accordance with the European Directive 2002/96/EG concerning used electrical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable. Check the appliance for transport damage before installing it. About use The appliance is intended solely for use in the household and must not be put to any other uses. In the event of malfunctions, first of all check the household fuses. If the problem has nothing to do with the power supply, please contact your specialist dealer or your local Gaggenau after-sales service. Features of your new appliance Island ventilation hood AI 260 Lighting Ventilation duct Control panel Grease filters Control panel Extraction level 1 Extraction level 2 Extraction level 3 Extraction level intensive Delayed shut-off Lighting Grease filter saturation display Motor off Accessories Special accessories You can order the following special accessories: • AA 260-196: Activated carbon filter Accessories for installation You can order the following accessories for installation: Installation accessories for exhaust air mode: • AD 260-016 for ceiling heights of 2.30 – 2.54 m • AD 260-026 for ceiling heights of 2.53 – 2.77 m • AD 260-036 for ceiling heights of 2.76 – 3.00 m Installation accessories for circulating air mode: • AD 260-116 for ceiling heights of 2.30 – 2.54 m • AD 260-126 for ceiling heights of 2.53 – 2.77 m • AD 260-136 for ceiling heights of 2.76 – 3.00 m Operation After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green. Light The lighting can be switched on or off, regardless of whether the extractor hood is in operation, by pressing the key. When you briefly press the key, the lighting is increased up to the maximum level. You can dim the lighting to the required level by keeping the key pressed. Fan levels or oror Three fan speeds and one intensive speed are available. You set the fan level required for each respective cooking situation by pressing the function selector keys 1, 2, 3 or Int. The Int key for the intensive level should be pressed when browning and frying in an open pan. If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the Int key while the hood is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes. If you would like to end the intensive level before the five minutes have elapsed, press the 0 key (“Motor off”) or select a different level. It is possible to switch off the extraction function at any time by pressing the 0 key (motor “off”). 10 Intensive time You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting. When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2. Delayed shut-off Delayed shut-off is possible at any level. First press the required key 1, 2, 3 or Int and then press the key. The delayed shut-off time for all levels is ten minutes. After these ten minutes, the ventilation switches off, but the lighting stays on. Interval ventilation Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by s...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien