Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung Bosch, modell AH530720/01

Hersteller: Bosch
Dateigröße: 780.68 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


1.3 About use – The appliance is intended solely for use in the household and must not be put to any other uses. – In the event of malfunctions, first of all check the household fuses. If the problem has nothing to do with the power supply, please contact your specialist dealer or your local Gaggenau after- sales service. 2. Features Fig. 2 1 2 3 4 Fig. 3 Motor off Extraction level 1 Extraction level 2 Extraction level 3 Extraction level intensive Run-on Lighting Grease filter saturation display 1 Outgoing air duct 2 Control panel 3 Grease filter 4 Lighting Installation accessories: Stainless steel-design ventilation duct: LK 530-010 for ceiling heights of 7 .. 3 . . - 8 .. 6 . . / 2.20 - 2.66 m LK 530-020 for ceiling heights of 8 .. 6 . . - 10 .. 1 . . / 2.66 - 3.15 m Aluminium-design ventilation duct: LK 530-011 for ceiling heights of 7 .. 3 . . - 8 .. 6 . . / 2.20 - 2.66 m LK 530-021 for ceiling heights of 8 .. 6 . . - 10 .. 1 . . / 2.66 - 3.15 m 3. Operation Fig. 4 The AH 530-790 is 35 3/8 . . / 90 cm wide, and the AH 530-720 is 47 3/16 . . / 120 cm wide. Operation of both extractor hoods is identical. After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green. Light The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the key (see Fig. 4). When you briefly press the key, the lighting is increased up to the maximum level. You can dim the lighting to the required level by keeping the key pressed. Fan levels Three fan speeds and one intensive speed are available (see Fig. 5). You set the fan level required for each respective cooking situation by pressing the function selector keys 1, 2, 3 or Int. or or or Fig. 5 Fig. 6 Fig. 7 Fig.. 8 The Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the Int key while the hood is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes (see Fig. 7). If you would like to end the intensive level before the five minutes have elapsed, press the 0 key (“Motor off”) or select a different level (see Fig. 8). You can of course switch off the hood’s extraction function at any time by pressing the 0 key (“Motor off”). 9 Special functions: Intensive time: You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2. Delayed shut-off: Delayed shut-off is possible at any level. First press the required key 1, 2, 3 or Int and then press the key (see Fig. 10). The delayed shut-off time for all levels is ten minutes. After these ten minutes, the ventilation switches off, but the lighting stays on. Interval ventilation: Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key (see Fig. 11). This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator. You can switch off interval ventilation by pressing the 0 key (see Fig. 12). Fig. 12 Fig. 10 or or or Fig. 9 or or Fig. 11 or or 10 Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filter (see Fig. 3). The grease filter can of course be cleaned at any time, even if the grease filter saturation display should not start to flash. The stainless steel grease filters can be removed easily for cleaning (see Fig. 13): Grip the grease filter handle and push the slide towards the rear. Then pull the grease filter downwards out of the holder; repeat the operation for the other grease filters. You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 150 °F / 65 °C, where it should be supported vertically to allow food or rinsing residues to drain off. The inner parts of the housing should be wiped out with hot rinsing water when replacing the filters. Note: When cleaning the inside of the housing avoid protruding parts. After having cleaned them, re-insert the grease filters in the hood in reverse order. Important: The handles of the grease filters must be visible after assembly. Press the F key to set the elapsed hours counter to zero. Flashing of the indicating lamp goes off. 4. Cleaning and care Fig. 13 Fig. 14 Fig. 15 Fig. 15 Cleaning the extractor hood Clean the extractor hood and the aluminium- design ventilation ducts (LK 530-011/021) with a soft clot...

Dieses Handbuch ist für folgende Modelle:
Dunstabzugshauben - AH530790/01 (780.68 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien